background image

1-4-1

120Rh-1

1.4 Model 120Rh-1

N8100-1388F

N8100-1389F

N8100-1390F

N8100-1391F

N8100-1438F

N8100-1392F

Dual-Core Xeon

E5205

Dual-Core Xeon

X5260

Quad-Core Xeon

E5405

Quad-Core Xeon

E5420

Quad-Core Xeon

X5450

Quad-Core Xeon

X5460

1.86GHz

3.33GHz

2GHz

2.50GHz

3GHz

3.16GHz

1066MHz

Memory

Standard Capacity

Maximum Capacity

Standard Capacity

Maximum Capacity

Disk Controller

RAID 

*7

Hot-Plug

FDD (USB)

Graphics

Chip

VRAM

Dimension
(WxDxH)mm

600VA/590W

630VA/620W

630VA/620W

630VA/620W

710VA/700W

710VA/ 700W

467VA/457W

474VA/464W

474VA/464W

474VA/464W

486VA/476W

486VA/ 476W

Optical disk drive

LAN Interface

2x6MB

Integrated in the Server Management Controller

Device Bays (3.5") [open]

Expansion Slots [open]

Disk Drive Bays(2.5”) [open]

No. of CPU

Internal
HDD

48GB (4GB x12) (when standard DIMMs are removed)

Server Management

- (dedicated for FDD)

6[6]

Windows Server 2003, Standard Edition (SP1 or later) / Enterprise Edition (SP1 pr later)

Windows Server 2003 R2, Standard Edition /Enterprise Edition

Windows Server 2003 R2, Standard x64 Edition / Enterprise x64 Edition

Red Hat Linux 

*7

Full-Height slots
  PCI Express (x8) : 1[1] 

*4

Option (not included in server as standard)

Option (not included in server as standard)

Serial(D-Sub 9pin) x2 (front x1, fear x1), USB2.0 x6 (front x2, fear x2, internal x2),

1000BASE-T(RJ-45) x2, LAN for Management(100BASE-TX) x1

Display(Mini D-Sub 15pin) x1, Keyboard/Mouse(PS/2) x1

*5

During operation: 10 to 35ºC / 20 to 80% (Non-condensing)

When stored: -10ºC to 55ºC / 20% to 80% (Non-condensing) 

*6

                            Standby

Consumption power  Max.

Supported OS
(see chapter of S/W for details)

Power supply

Weight std. (max.)

Cooling fan

Keyboard

Temperature and Humidity Condition

Main unit form

Mouse

CD-RW/DVD-ROM Combo drive

*3 

x1 (DVD:x8 max. speed, CD: x24 max. speed)

16Kg (20Kg)

LowProfile slots
  PCI Express (x8) : 1[0] (occupied by RAID controller)

1000BASE-T x2 (100BASE-TX and 10BASE-T are supported) (standard)

Standard: Not redundant, Option: Redundant

Redundant (standard)

8MB

19inch rack mountable, 1U rack height

Server Management Controller (EXPRESSSCOPE Engine 2) is installed as standard.

425 x 718 x 43

485 x 823 x 43 (when front bezel and the protruding objects are included)

MODEL

Model 120Rh-1

N-code

CPU

2.5-inch hard disk drive model

External Interface

Clock

2nd Cache

1 (standard) - 2 (max.)

DDR2-667 FB-DIMM, x4/x8 SDDC, Memory Mirroring, On-line Spare Memory

6MB

Chip set

Intel® 64

Intel 5000P

Supported

Front Side Bus

Supported

RAID 0,1: Standard

*1

, RAID 5,6: Option

Option

*2

1333MHz

SAS 879GB (146.5GB x 6)

SAS

2GB (1GB x2)

Diskless

*1 On-board RAID is not supported on Linux configuration.
*2 The Internal FDD is not available for 2.5” hard disk drive models.
*3 Writing software is not supported.
*4 2.5-inch hard disk drive models do not provide the Riser Card option.
*5 The keyboard and  mouse can be connected together by using a Y cable provided with the main unit.
*6  When stored at a low or high temperature, the system clock may largely deviate from the current time.
*7 Please refer to “Linux on NEC Express5800” (

http://www.nec.co.jp/express/linux/index.html

)

Features

• 1U slim rack-optimized
• Quad-Core Xeon E5405/E5420/X5450/X5460 and Dual-Core Xeon E5205/X5260
• DDR2-667 FB-DIMM memory of up to 48GB with memory mirroring

and on-line spare

• Universal hard disk bays supporting up to 900GB SAS and 2.25TB SATA

Содержание 120Rh-1

Страница 1: ... chapter of S W for details Power supply Weight std max Cooling fan Keyboard Temperature and Humidity Condition Main unit form Mouse CD RW DVD ROM Combo drive 3 x1 DVD x8 max speed CD x24 max speed 16Kg 20Kg LowProfile slots PCI Express x8 1 0 occupied by RAID controller 1000BASE T x2 100BASE TX and 10BASE T are supported standard Standard Not redundant Option Redundant Redundant standard 8MB 19in...

Страница 2: ...ted OS see chapter of S W for details Power supply Weight std max Cooling fan Keyboard Temperature and Humidity Condition Main unit form Mouse Server Management dedicated for FDD 3 3 Windows Server 2003 Standard Edition SP1 or later Enterprise Edition SP1 pr later Windows Server 2003 R2 Standard Edition Enterprise Edition Windows Server 2003 R2 Standard x64 Edition Enterprise x64 Edition Red Hat L...

Страница 3: ... form Mouse Disk Drive Bays 2 5 open During operation 10 to 35ºC 20 to 80 Non condensing When stored 10ºC to 55ºC 20 to 80 Non condensing 5 Standby 425 x 718 x 43 485 x 823 x 43 when front bezel and the protruding objects are included Consumption power Max Server Management Serial D Sub 9pin x2 front x1 rear x1 USB2 0 x4 front x2 rear x2 internal x2 1000BASE T RJ 45 x2 LAN for Management 100BASE T...

Страница 4: ...P LED SERIAL PORT LAN1 ACCESS LED POWER SWITCH USB CONNECTOR UID LED UID SWITCH External Design 120Rh 1 2 5 inch HDD model PCI SLOT SERIAL PORT DUMP SWITCH PCI SLOT AC INLET option Low Profile CONNECTOR Full Height USB CONNECTOR AC INLET LAN CONNECTOR DISPLAY CONNECTOR UID LED LAN2 CONNECTOR for MS KB CONNECTOR UID SWITCH LAN1 CONNECTOR SERVER MANAGEMENT ...

Страница 5: ...H USB CONNECTOR UID LED UID SWITCH DVD ROM DRIVE FDD BAY DISK ACCESS LED STATUS LED HARD DISK BAYs LAN2 ACCESS LED DUMP SWITCH PCI SLOT SERIAL PORT DUMP SWITCH PCI SLOT AC INLET option Low Profile CONNECTOR Full Height USB CONNECTOR AC INLET LAN CONNECTOR DISPLAY CONNECTOR UID LED LAN2 CONNECTOR for MS KB CONNECTOR UID SWITCH LAN1 CONNECTOR SERVER MANAGEMENT ...

Страница 6: ...ER SWITCH USB CONNECTOR UID LED UID SWITCH DVD ROM DRIVE FDD BAY DISK ACCESS LED STATUS LED HARD DISK BAYs LAN2 ACCESS LED DUMP SWITCH Rear View PCI SLOT SERIAL PORT DUMP SWITCH PCI SLOT USB CONNECTOR Low Profile CONNECTOR Full Height AC INLET LAN CONNECTOR DISPLAY CONNECTOR UID LED LAN2 CONNECTOR for MS KB CONNECTOR UID SWITCH LAN1 CONNECTOR SERVER MANAGEMENT ...

Страница 7: ...mory The 120Rh 1 supports up to 48GB Maximum available memory See the table below for the maximum memory size that you can actually use on your system The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB The PCI resource capacity varies by type and number of PCI cards you are using CPU Kit XD ...

Страница 8: ... standard memory mode memory mirroring and online spare memory at the same time in the same system Not redundant default Same as physical capacity Not removable during operation Not redundant In the event of a memory failure a spare DIMM takes over a faulty DIMM online A faulty DIMM automatically fails over to a spare memory on the same memory branch Physical capacity does not include spare memory...

Страница 9: ...ports up to eight servers Allows the connection of up to 64 servers by cascading the Server Switch Units N8191 10F Video I F Mini D sub 15pin Switch Unit Connection Cable Set 1 8m 3m 5m K410 119 1A 1 8m K410 119 03 3m K410 119 05 5m 1 Keyboard Mouse I F PS 2 Y cable provided with the main unit 17 inch LCD 1280x1024 max Full color 1 Local procurement Display PCI on board 104 key keyboard US English...

Страница 10: ...A slim type 2 mode N8151 73A is not available for 2 5 inch hard disk drive models FDD Provide either a Built in or an External FDD for maintenance and OS installation purpose Automatic System Recovery of Windows Server 2003 operating system and Disaster Recovery Option of backup software are available for both FDD 2003 R2 R2x64 EL4 EL4x64 2003 R2 R2x64 EL4 EL4x64 1 CD RW DVD ROM combo drive standa...

Страница 11: ...nit is supplied as standard To configure hot plug Redundant Power Supply in the 120Rh 1 except non redundant models N8100 1401F 1402F 1405F use an optional power supply unit N8181 50F 2 Power Unit Empty slot N8181 50F Power Unit Fans Rack mount option N8143 70 Cable Arm The Cable arm N8143 70 is used to bundle cables at rear The dimension with the Cable arm N8143 70 is 485Wx890Dx43Hmm including fr...

Страница 12: ...N8150 220 146 5GB HDD 10 000rpm N8150 228 36 3GB HDD 15 000rpm N8150 240 73 2GB HDD 15 000rpm N8150 241 HDDs 2 5 inch SAS HDD HDD Configuration HDD Configuration Allows up to six HDDs Supports RAID0 1 To configure RAID 5 and 6 a RAID Upgrade Kit N8103 119 is required HDD Configuration 2 2 5 inch hard disk model model SAS RAID0 1 5 6 Hot Plug 2003 R2 R2x64 EL4 EL4x64 2003 R2 R2x64 EL4 EL4x64 Disk b...

Страница 13: ...D 7 200rpm N8150 207A 160GB HDD 7 200rpm N8150 208A 250GB HDD 7 200rpm N8150 209A 500GB HDD 7 200rpm N8150 229 750GB HDD 7 200rpm N8150 237 HDDs 3 5 inch SATA HDD Allows up to three HDDs Supports RAID0 1 LSI Logic Embedded MegaRAID 2003 R2 R2x64 Internal Serial ATA I F Serial ATAII 300 HDD Configuration 4 3 5 inch hard disk model SATA RAID 0 1 Hot Plug 2003 R2 R2x64 ...

Страница 14: ...Insert into PCIe slot RAID controller N8103 116 PCIe x8 RAID 0 1 128MB cache Internal SAS I F Additional DAC battery RAID Battery Backup Unit N8103 120 HDDs 3 5 inch SAS HDD 36 3GB HDD 15 000rpm N8150 199 73 2GB HDD 15 000rpm N8150 200 146 5GB HDD 15 000rpm N8150 201 300GB HDD 15 000rpm N8150 226 HDD Configuration 6 3 5 inch hard disk model SAS SATA RAID 0 1 5 Hot Plug 2003 R2 R2x64 Insert into PC...

Страница 15: ... Ultra320 SCSI SCSI controller N8103 107 Ultra320 SCSI You cannot use N8103 75 and N8103 107 at the same time 2003 R2 R2x64 EL4 EL4x64 2003 R2 R2x64 2003 R2 R2x64 EL4 EL4x64 PCI slot N8103 104 SAS controller SATA SAS Disk Array Unit 2003 R2 R2x64 N8190 120 Fibre channel controller Fibre Channel Disk Array Unit 1ch 2Gbps optical N8190 127 Fibre channel controller NEC Storage S Series Fibre Channel ...

Страница 16: ...e 2 with Remote KVM and Media License N8115 03 DianaScope x CUI screen OS console x Panic screen Boot screen Remote console via COM port LAN x HW err Boot err and OS panic by SNMP E Mail via LAN Alerting Monitor booting BIOS POST stall OS stall shutdown Collecting hardware event log Monitor temperature voltage FAN degeneration CPU memory x Stole monitoring Automatic reboot x x Monitoring server No...

Страница 17: ...press x4 10GbE adapter 1 port PVI Express x8 1000BASE SX adapter 64bit 133MHz PCI X 1000BASE T adapter PCIe PCI Express x1 100BASE TX adapter 32bit 33MHz PCI 1000BASE T 2 port 64bit 133MHz PCI X 1000BASE T adapter 2 port PCI Express x4 RAID controller RAID 0 1 5 6 128MB PCI EXPRESS x8 Product name SCSI controller 64bit 66MHz PCI RAID controller RAID 0 1 128MB PCI EXPRESS x8 SAS controller PCI EXPR...

Страница 18: ...x8 SAS controller PCI EXPRESS x8 SCSI controller PCI EXPRESS x1 Fibre channel controller 2ch 4GbFC LP PCI Express x4 10GbEadapter 1 port PVI Express x8 1000BASE T adapter PCIe PCI Express x1 1000BASE T adapter 2 port PCI Express x4 Optional Boards and Adaptable Expansion Slots 2 5 inch hard disk drive models N8100 1388F 1389F 1390F 1391F 1438F 1392F Note You cannot create an AFT or ALB team across...

Страница 19: ... drive models 2 3 5 inch hard disk drive models with the optional RAID Controller N8103 116 3 5 Hard Disk Drive SATA ID 0 3 5 Hard Disk Drive SATA ID 1 3 5 Hard Disk Drive SATA ID 2 3 5 Hard Disk Drive SAS SATA ID 0 3 5 Hard Disk Drive SAS SATA ID 1 3 5 Hard Disk Drive SAS SATA ID 2 ...

Страница 20: ...1 4 20 120Rh 1 3 Standard Configuration of the 2 5 inch Hard Disk Drive Models RAID Controller Standard 2 5 Hard Disk Drive SAS ID 0 1 2 5 Hard Disk Drive SAS ID 2 3 2 5 Hard Disk Drive SATA ID 4 5 ...

Отзывы: