NEO IP/GSM Technical Handbook
Document number: NE41 09002-02 v2.0
8.7.2
Internal
These alarms are also mentioned technical alarms due to their nature. The
checkbox indicates whether the alarm is activated or not.
Test alarm
If Test Alarm is checked, the NEO IP/GSM will periodically send an notification to
a selected receiver, e.g. an alarm central or a test alarm receiver. By default this
alarm is silent, i.e. the NEO IP/GSM does not dial in speaker nor is the speaker ac-
tivated during the communication. The receiver is determined on the
Sequences
tab - Test alarm
and the peridiocity is determined on the
Timers and Indica-
tions tab - Test Alarm Interval
.
Mains failure
Should the AC adaptor fail or accidentally be removed, the unit automatically
switches to the accumulator and the unit can send a Mains failure alarm.
NB! If power failure occurs in the building, this usually means the power for the
Internet connection is also lost. But, if the NEO IP/GSM is equipped with a GSM
module, the alarm is sent over the GSM network
Mains OK
When the AC power returns to the unit the unit can be set to send
Mains OK
.
Radio interference
NEO IP/GSM is monitoring the radio environment and detects if there is radio in-
terference and can send an alarm if this occurs. Radio inteferences lasting shorter
than 2 minutes does not trigger this alarm, i.e. shorter interferences may occur
but will not trig the alarm.
Radio out of range
By default an ATOM contacts its host, in this case the NEO IP/GSM, every 9 hour
to say “Here I am!”. If the transmission is successful (i.e. the NEO IP/GSM receives
the signal) the NEO IP/GSM resets a timer, expecting next transmission within 73
hours (default value is 73 hrs). Should no new transmission occur within these 73
hours, then the NEO IP/GSM can be set to send a
Radio out of range alarm
.
Radio within range
When the ATOM returns within radio range the NEO IP/GSM can be set to send a
Radio within range alarm
.
Accumulator
NEO IP/GSM constantly monitors the health and status of the accumulator.
Should any parameter deviate from a given specification then the NEO IP/GSM
can send an
Accumulator alarm
.
NEO IP Programmer software