INKA, IOR, REPO & LINK
3.3 Wired Output: IOR, REPO and LINK
The wired output consists of a relay with two positions. In one position, the
ON
position, the relay
connects pin 3 and 4 in the output connector. In the other position, the
OFF
position, the relay
connects pin 3 and 5 in the output connector, see section 1.9.
The behavior of the output relay when a wired input is trigged or when a radio message is received is
here referred to as the
relay action
. The table below lists the 5 possible actions that the output relay
can perform when an input is trigged.
Relay Action
Description
None
The relay remains in its previous state
Relay on
The relay switches to the
ON
position
Relay off
The relay switches to the
OFF
position
Toggle relay
The relay changes state, from
OFF
to
ON
or from
ON
to
OFF
.
Pulse relay
The relay switches to the
ON
position, waits for a
pre-configured time and then switches to the
OFF
position.
3.3.1 Pulse Activation Time
The time that the relay remains in its ON position during the
Pulse relay
action is determined by the
Pulse activation time
parameter under the
preferences
tab in IOR Programmer.
IOR
REPO
LINK
Configure the output relay to stay in its
ON position during 5.5 seconds when the
Pulse relay
action is performed
Enter “5.5” in text box 309
3.3.2 Relay Action when Wired Input is Trigged
The relay action can be configured individually for each wired input.
IOR
Configure the output relay to remain
unchanged when input 1…5 is trigged
Select “None” in list box 211…215
IOR
Configure the output relay to switch to the
ON
position when input 1…5 is trigged
Select “Relay on” in list box 211…215
IOR
Configure the output relay to switch to the
OFF
position when input 1…5 is trigged
Select “Relay off” in list box 211…215
IOR
Configure the output relay to change state
when input 1…5 is trigged
Select “Toggle relay” in list box 211…215
IOR
Configure the output relay to switch
ON
,
and then
OFF
when input 1…5 is trigged
Select “Pulse relay” in list box 211…215
Technical Handbook for the IOR Family (firmware v20.x), document number NE41 06007-02 v1.0