3
System setup
3.1
Preface
The following examples are common scenarios where a D-SERVER can be success-
fully used.
There are many more scenarios not covered in this chapter, but the intention is to get
you started. The examples can easily be modified to support your requirements.
3.2 Scenario I
1
2
3
5
4
6
neat
Picture 38.
Scenario I with a D-BOX and D-TECTS
This scenario will cover how-to configure a D-Server with D-TREX 2G alarm receivers.
A D-BOX together with two D-TECT’s will be used as transceivers. The D-TECT’s will
communicate with the D-Server over a RS-485 bus. The end user will be equipped
with a SMILE-STD button.
• Up to 30 D-TECT’s can be installed.
• Max cable length per bus is limited to 1000 meters.
• The router is mandatory because of the DHCP server funcionality.
3.2.1 Hardware requirements
#
System component
Quantity
1
Router
1
2
D-SERVER
1
3
D-BOX
1
4
SMILE STD
1
5
D-TREX2G
1
6
D-TECT
2
Table 23.
Required scenario components