When the battery is being charged at temperatures
below 0°C, the cell heating system (for models with an
"F") is activated. The system uses the charger's energy
to power itself and, once the ideal charging
temperature is reached, the heating is switched off and
charging begins.
If, during charging, the temperature is higher than the
permissible range, the internal manager will limit the
charge to preserve battery life.
15.DISCHARGE
The
BMS Smart
(inside the battery), the electronic
system for protecting and managing the lithium cells,
supports a continuous current of 135A. However, it is
possible to use higher currents for a limited time, in
accordance with the following values.
19
Model
Min. Charging
temperature
Max. Charging
temperature
TLB 100
-10°C
+45°C
TLB 100F
-30°C
+45°C
TLB 120
-10°C
+45°C
TLB 120F
-30°C
+45°C
TLB 150
-10°C
+45°C
TLB 150F
-30°C
+45°C
Max. Discharging time
Discharging
current
TLB 150 | TLB 150 F TLB 120 | TLB 120 F TLB 100 | TLB 150 F
150A
25 minutes
20 minutes
15 minutes
180A
5 minutes
3 minutes
2 minutes
200A
150 seconds
60 seconds
60 seconds