background image

ScaleOR™

Video Scaling System

USER MANUAL

ENGLISH

Содержание ScaleOR

Страница 1: ...ScaleOR Video Scaling System USER MANUAL ENGLISH ...

Страница 2: ......

Страница 3: ...e without notice NDS provides this information as reference only Reference to products from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDS All trademarks are the property of the...

Страница 4: ......

Страница 5: ...d Installation 6 Tab 4 System Configuration Example 7 Tab 5 Startup 8 Tab 6 Control 9 Menu Overview 9 ScaleOR Setup 10 DVI and SDI Picture Menu 10 VGA RGBS YPbPr and SOG Menu 11 Color Menu 12 Setup Menu 13 Modes Menu 14 Output Modes Table 15 Restoring Factory Defaults 15 Tab 7 Serial Port Setup and Test 16 Tab 8 Troubleshooting and Test Section 17 Tab 9 Drawing and Dimensions 18 Tab 10 Connectors ...

Страница 6: ... symbol denotes the manufacturer This symbol denotes the manufacturer s European Community representative To prevent fire or shock hazards do not expose this unit to rain or moisture Also do not use this unit s polarized plug with an extension cord receptacle or other outlets unless the prongs can be fully inserted The product is designed to meet the medical safety requirements for a patient vicin...

Страница 7: ...appropriate they reserve all patent copyright and other proprietary rights to this document including all design manufacturing reproduction use and sales rights thereto except to the extent said rights are expressly granted to others FCC and Council Directives of European Standards This device complies with Part 15 of FCC rules and 93 42 EEC of the Council Directives of European Standards Directiv...

Страница 8: ...y video and graphic images Contraindications This device may not be used in the presence of flammable anesthetics mixture with air oxygen or nitrous oxide Also it is not intended for life support applications No part of this product may come in contact with a patient Never touch the product and a patient at the same time Warning Because invisible laser radiation may be emitted from the aperture of...

Страница 9: ...tional feature Control Options The ScaleOR may be controlled from 1 The keypad on the front of the ScaleOR Using the keypad requires that the ScaleOR be connected to a display 2 A PC via the ND OS port See Serial Port Setup and Test on page 16 The NDS Unified Serial Commands P N 60A0156 document contains a complete set of serial commands for the ScaleOR Please contact your NDS sales representative...

Страница 10: ... 6 The ND OS connector allows the ScaleOR to be controlled remotely via serial commands It is also used to install BIOS upgrades SDI and DVI video outputs Power Switch The Power Switch symbol is shown to the left The power switch is push on push off and is shown below the Power Switch symbol When the switch is off the ring around the center portion is white When the switch is on the center portion...

Страница 11: ... O F O O F O 19 1920x1080 59 94P 1920x1080 59 94P O F O O F F 20 1920x1080 60 00P 1920x1080 60 00P O F O F O O 21 640x480 60 VGA N A O F O F O F 22 640x480 75 VGA N A O F O F F O 23 640x480 85 01 VGA N A O F O F F F 24 800x600 60 32 SVGA N A O F F O O O 25 800x600 75 SVGA N A O F F O O F 26 800x600 85 06 SVGA N A O F F O F O 27 1024x768 60 XGA N A O F F O F F 28 1024x768 75 03 XGA N A O F F F O O ...

Страница 12: ...e as shown Press and hold the button labeled PUSH Twist the adapter 1 8 turn toward the OPEN arrow and lift it off the power supply Select one of the provided wall adapters Align the tabs on the bottom of the adapter with the notches on the power supply and place the adapter on the power supply Press the adapter down and twist it toward the LOCK arrow until it clicks into place ...

Страница 13: ...rews located on the left and right sides of the module s mounting plate When the screws are clear of the chassis remove the module by gripping the screws and pulling the module out Installation Slide the new module into the chassis until it contacts the connector then push gently until the module seats The module is correctly seated when its mounting plate is flush with the chassis s back panel Th...

Страница 14: ...4 System Configuration Example 7 DVI Out SDI Out SDI DVI VGA or S Video Composite Source Optional PC control ...

Страница 15: ... not detected the ring continues flashing The NDS logo is displayed on the monitor until the ScaleOR s initialization is complete At which time the illuminated ring stops flashing if a video signal is detected and becomes steady blue At this time an image of the video signal connected to the ScaleOR s input is displayed on the monitor If the ScaleOR has been turned on for more than 15 seconds and ...

Страница 16: ...nt to work with then press the SCROLL button to select the parameter Press the fi or fl button to set the parameter to the desired value Press the MENU button to save your changes and close the OSM Notes 1 Grayed out parameters are not currently accessible Control A 4 button keypad located below and to the right of the ScaleOR logo allows the user to make adjustments to various ScaleOR parameters ...

Страница 17: ... and right 1 1 Displays the video data in its native size and aspect ratio Image may be displayed with black bars on the top and bottom and on the left and right Select using fi or fl buttons Zoom Video This parameter is enabled when the input is 16 9 480P 576P or interlaced 0 The image is displayed at a size that fills the screen without losing any video information The image presented to the dis...

Страница 18: ...with black bars on the top and bottom and on the left and right Select using fi or fl buttons Zoom Video This parameter is enabled when the input is 16 9 480P 576P or interlaced 0 The image is displayed at a size that fills the screen without losing any video information The image presented to the display may include black bars top and bottom or left and right 1 2 3 4 5 or 6 The image is linearly ...

Страница 19: ...to increase or decrease the intensity of the selected color Saturation Video This parameter is enabled only when the input is 16 9 480P 576P or interlaced Press fi or fl to set the saturation color intensity of the image Hue Video This parameter is enabled only when the input is 16 9 480P 576P or interlaced Press fi or fl to set the hue color tint of the image 12 ...

Страница 20: ...er allows the user compensate for input signals whose timing parameters may differ from those stored in the ScaleOR Press the fi or fl button to select one of the tolerance parameters The Alternative Mode Tolerance options are available with BIOS 58J0079 Rev D and later Menu Position Places the menu in 1 of 9 predefined screen positions Press the fi or fl button to select any of the 9 screen posit...

Страница 21: ...of modes 0 15 16 31 or 32 47 that contains the output mode that you want to use Press the SCROLL button to highlight the pair of modes that contains the mode to be used This message appears on the bottom of the OSM Press the fi or fl button to select the new output mode The following message appears on bottom of the OSM Press this button to confirm the new output mode The following message is show...

Страница 22: ... Only 1280x960 60Hz 0003 DVI SDI 1280x720p 24Hz 0019 DVI SDI 1920x1080p 59Hz 0035 DVI Only 1280x960 75Hz 0004 DVI SDI 1280x720p 25Hz 0020 DVI SDI 1920x1080p 60Hz 0036 DVI Only 1280x960 85Hz 0005 DVI SDI 1280x720p 29Hz 0021 DVI Only 640x480 60Hz 0037 DVI Only 1280x1024 60Hz 0006 DVI SDI 1280x720p 30Hz 0022 DVI Only 640x480 75Hz 0038 DVI Only 1280x1024 75Hz 0007 DVI SDI 1280x720p 50Hz 0023 DVI Only ...

Страница 23: ...OM Properties menu Set Bits per second to 19200 Set Data bits to 8 Set Parity to None Set Stop bits to 1 Set Flow control to None Click OK Click File click Properties then select ASCII Setup from the Properties menu In the ASCII Setup menu select Echo typed characters locally Click OK to exit ASCII Setup Click OK to exit configuration Click File and select Save to save the configuration Serial Por...

Страница 24: ... the video cable If video appears then the cable is bad If video does not appear then connect the unit to a different video source If video appears then the previous video source is turned off or defective If video still does not appear then the ScaleOR s Input module may be defective or not properly seated Try reseating the input module If that doesn t clear the problem then the input module is d...

Страница 25: ...Drawing and Dimensions 9 18 ...

Страница 26: ...d C 3 Y Intensity Luminance 4 C Color Chrominance Input Connectors Pin Name Description 1 VCC 5 VDC 2 D Data 3 D Data X ID N C 4 GND Ground USB Connector Data Connector Pin Name Description Input Input Serial Video Data Fiber Optic Output Connector Compliant with DVI 1 0 PIN SIGNAL PIN SIGNAL 1 T M D S DATA 2 16 HOT PLUG DETECT 2 T M D S DATA 2 17 T M D S DATA 0 3 T M D S DATA 2 4 SHIELD 18 T M D ...

Страница 27: ...Resolution User selectable See Output Modes Table on page 15 HD SDI Input signal level 8 to 2 0 V p p DC Power Consumption 22W AC Power Consumption 30W System Weight 0 59 kg 1 3lbs Environmental Operating Temperature 0 to 350 C 32 to 950 F Operating Humidity 20 to 85 RH Storage Temperature 20 to 500 C 4 to 1220 F Storage Humidity 5 to 85 RH Operating Altitude 2 000 m 6 600 ft Storage Altitude 10 0...

Страница 28: ...1280 720p 24 1920 1080p 29 97 640 480 85 01 1280 720p 25 1920 1080i 25 720 400 70 1280 720p 30 1920 1080i 29 97 720 400 85 04 1280 720p 50 1920 1080p 50 800 600 56 25 1280 720p 59 94 1920 1080p 59 94 800 600 60 32 1280 960i 29 97 1920 1200 30 800 600 60 38 1280 960 59 94 1920 1200 50 800 600 72 19 1280 960 60 800 600 75 1280 960 75 800 600 85 06 1280 960 85 The DVI D input can automatically detect...

Страница 29: ...s with a lint free cloth dampened with 80 Ethyl Alcohol Allow the unit to air dry Cautions Do not allow liquids to enter the interior of the unit and do not permit exterior surfaces to come into contact with unacceptable solvents such as those listed below as severe damage to the unit may result Acceptable Cleaning Materials Vinegar distilled white vinegar 5 acidity Ammonia based glass cleaner Acc...

Страница 30: ...on provided in this manual and verification of all medical devices in simultaneous operation are required to ensure the electromagnetic compatibility and co existence of all other medical devices prior to a surgical procedure The EMC tables on next three pages are provided for your reference Electromagnetic Compatibility EMC Tables 23 ...

Страница 31: ...evel Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burst IEC 61000 4 4 2 kV for power supply lines 2 kV for power supply lines Mains power quality should be tha...

Страница 32: ...by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects...

Страница 33: ...er Separation distance in meters according to frequency of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transm...

Страница 34: ......

Страница 35: ......

Страница 36: ...many 49 89 31 707 100 info novanta europe novanta com Asia Pacific Novanta Japan East Square Omori 6 20 14 Minamioi Shinagawa ku Tokyo 140 0013 Japan 81 3 5753 2466 info ndssi jp Oriental Media Center Suite 2302 Tower C No 4 Guang Hua Road Chao Yang District Beijing 100026 China 86 10 8559 7859 info ndssi com cn NDS Quality System ISO 9001 2008 and ISO 13485 2003 FDA Registration 2954921 ...

Отзывы: