background image

Version 20/01 – State September 2020 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruction manual and data sheet 

Torque Sensor Series 4000 

 

 

 

 

Содержание 4000 Series

Страница 1: ...Version 20 01 State September 2020 Instruction manual and data sheet Torque Sensor Series 4000 ...

Страница 2: ... NCTE AG Torque Sensor Series 4000 Instruction Manual and Data Sheet This instruction manual is property of NCTE AG D 82041 Oberhaching Unauthorized duplication even in part is not permitted State September 2020 ...

Страница 3: ...hange 7 2 4 Training of the operating personnel 7 2 5 Transport and handling 7 3 Torque Sensor Series 4000 8 3 1 Short description 8 3 2 Assembly and disassembly 8 3 3 Interface description 8 3 4 Starting up 8 3 5 Operation during regular mode 9 3 6 Irregular operation actions in case of failures 9 3 7 Safety instructions 9 3 8 Shaft preservation 9 3 9 Service maintenance and repair 9 3 10 Disposa...

Страница 4: ...Facts 10 2 Torque ranges 10 3 Load characteristics 11 4 Technical characteristics 11 5 EMV Emission data 12 6 Dimensions 13 7 Wiring diagram 14 8 Sensor wiring 14 9 Angle sensor 14 10 Order options 15 11 Accessories 15 ...

Страница 5: ... try to maintain compatibility with previous versions All information without guarantee subject to technical changes For further questions we are of course also available after the purchase at any time Please use our contact address 1 1 Customer service address NCTE AG Raiffeisenalle 3 D 82041 Oberhaching Phone 49 0 89 665 619 0 Email sales ncte de Web https ncte com 1 2 Warranty The warranty peri...

Страница 6: ...4000 100 4000 250 round shaft 4000 1000 round shaft conforms to the requirements of the EMC Directive 2014 30 EU including its amendments in force at the time of this declaration The following harmonized standards were applied EN 61000 6 2 2019 11 EN 61000 6 4 2020 09 EN 61326 1 2013 07 EN 61326 1 2018 09 Draft The following national laws standards and specifications were applied Electromagnetic c...

Страница 7: ...e is considered improper The manufacturer is not liable for any damage resulting from such use 2 2 Duration of use A factory recalibration should be executed annually See corresponding label on the sensor 2 3 Structural change Unauthorized conversions or changes to the torque measuring system are prohibited for safety reasons and lead to the immediate expiration of the warranty claims 2 4 Training...

Страница 8: ... connection shafts onto the key adapter connections square connections of the sensor without any effort No force must be exerted on the housing in the axial direction during fastening The sensor can be secured against rotation by means of the flat surface optional sensor holder The cable length must not exceed 5m Using a cable other than the one supplied by NCTE or an identical cable with a differ...

Страница 9: ...not be loosened or tightened Only use power supplies safely disconnected from the mains voltage Regarding the electrical and mechanical load of the sensor the specifications according to the sensor specific nameplate and the table in Chapter 4 Technical characteristics must be observed The sensor is not to be used as support bearing The existing fastening options serve exclusively to secure the ho...

Страница 10: ...s measuring system Delivery including 5 m cable and calibration certificate Suitable accessories readout unit couplings 2 Torque ranges Model line Series 4000 Round shaft Nominal torque bidirectional Nm Limiting torque unidirectional Nm Limiting torque bidirectional Nm RPM rpm Ø 15 mm 50 65 65 10000 100 130 130 Ø 25 mm 250 325 325 8000 Ø 40 mm 1000 1300 1300 5000 Model line Series 4000 Square shaf...

Страница 11: ...ce is permissible 2 The accuracy class means that the linearity deviation as well as the circulation modulation individually are each less than or equal to the value specified as the accuracy class The accuracy class must not be confused with a classification according to DIN 51309 or EA 10 14 3 ME Related to the measuring range 4 Zero point can be set to 5 V using a tare button 5 The exact sensor...

Страница 12: ...ISPR 11 2009 A1 2010 Class B Limit values observed Radio interference field strength 30 1000 MHz CISPR 11 2009 A1 2010 Class B Limit values observed 6 Wiring connected 7 Based on the non contact measurement principle the torque sensor is quite insensitive to bending and shearing forces Self aligning couplings are recommended in case of dynamic loads 14 Signal drift over temperature within nominal ...

Страница 13: ...ions keystone mm Keystone DIN 6885 Keystone position Shaft Width Depth Length Height Length Amount Distance L Ø 15 mm 5N9 3 25 5 5 25 1 130 5 Ø 25 mm 8N9 4 50 5 7 50 2 165 5 Ø 40 mm 12N9 5 90 5 8 90 2 252 0 For high alternating loads torque transmission by positive and frictional locking via a suitable fit or coupling is recommended Dimensions square shaft mm A B C D E F G H I 50 Nm 130 93 18 5 3 ...

Страница 14: ... F Pink Angle Ch A 0V 5V G Blue Angle Ch I 0V 5V H Red Angle Ch B 0V 5V J Black K Purple For internal use only RX TTL Pegel L Grey Pink For internal use only RX TTL Pegel M Red Blue Digital GND 8 Sensor wiring 9 Angle sensor Parameter Min Typ Max Einheit High Level Output Voltage 2 4 5 V Low Level Output Voltage 0 0 4 V Parameter Description C One cycle of 360 CPR degrees P The duration of high st...

Страница 15: ...th further information about serial products in a personal contact under Phone 49 0 89 66 56 19 30 or by e mail sales ncte de 11 Accessories Readout unit A Order number 400010 ATS001 Art No 400010005 Sensor input Voltage output 0 5 V and 0 10 V 1 x angle encoder input A B USB interface Software Windows included SD card slot to use for data logging B Order number 400010 ATS002 Art No 400010006 Sens...

Страница 16: ...Your experts for magnetostrictive sensors ...

Отзывы: