background image

NCR — CONFIDENTIAL AND PROPRIETARY

Use pursuant to Company Instructions

NCR K150/F150 IMAGING 

MODULE

Programming Guide

B005-0000-2166
November 2012

Front Cover

Содержание K150

Страница 1: ...NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions NCR K150 F150 IMAGING MODULE Programming Guide B005 0000 2166 November 2012 Front Cover ...

Страница 2: ...easures Information to User This equipment must be installed and used in strict accordance with the manufacturer s instructions However there is no guarantee that interference to radio communications will not occur in a particular commercial installation If this equipment does cause interference whichcanbedeterminedbyturningtheequipmentoffandon theuser isencouragedtoconsultan NCRservice representa...

Страница 3: ...REVISION RECORD Date Revision Page Description of Change May 2011 A All Initial Release Conversion from third party document to IP standards ...

Страница 4: ...aintain the quality of NCR publications please send feedback on their accuracy clarity or usability to userfeedback exchange scotland ncr com For technical or sales queries please contact your local NCR support ...

Страница 5: ...PLAY 2 1 USB IBM SurePos 2 1 USB PC or Macintosh Keyboard 2 2 USB HID 2 2 USB Serial 2 3 CTS RTS Emulation 2 3 ACK NAK Mode 2 3 Datalogic Magellan Bi Optic Aux Port Configuration 2 4 NCR Bi Optic Aux Port Configuration 2 4 Chapter 3 Input and Output Settings MANUAL TRIGGER MODES 3 1 Normal Mode 3 1 Enhanced Mode 3 1 PRESENTATION MODE 3 2 Presentation LED Behavior after Decode 3 2 Presentation Sens...

Страница 6: ...AR 4 4 Codabar Start Stop Characters 4 4 Codabar Check Character 4 5 Codabar Concatenation 4 6 Codabar Message Length 4 7 CODE 39 4 8 Code 39 Start and Stop Characters 4 9 Code 39 Check Character 4 9 Code 39 Message Length 4 10 Code 39 Append 4 11 Code 32 Pharmaceutical PARAF 4 12 Full ASCII 4 13 Code 39 Code Page 4 14 INTERLEAVED 2 OF 5 4 15 Interleaved 2 of 5 Check Digit 4 15 Interleaved 2 of 5 ...

Страница 7: ...umber System 4 42 UPC E0 Addenda 4 43 UPC A Addenda Required 4 44 UPC E1 4 44 EAN JAN 13 4 45 EAN JAN 13 Check Digit 4 45 EAN JAN 13 Addenda 4 46 EAN JAN 13 Addenda Required 4 47 EAN JAN 13 Addenda Separator 4 47 ISBN Translate 4 48 EAN JAN 8 4 48 EAN JAN 8 Addenda 4 50 EAN JAN 8 Addenda Required 4 51 MSI 4 52 MSI Check Character 4 52 MSI Message Length 4 54 GS1 DATABAR OMNIDIRECTIONAL 4 54 GS1 DA...

Страница 8: ...LINEAR 4 87 China Post Hong Kong 2 of 5 4 87 China Post Hong Kong 2 of 5 Message Length 4 88 Korea Post 4 88 Korea Post Message Length 4 89 Korea Post Check Digit 4 89 Chapter 5 Imaging Commands INTRODUCTION 5 1 Single Use Basis 5 1 COMMAND SYNTAX 5 2 STEP 1 TAKING A PICTURE USING IMGSNP 5 3 Image Snap IMGSNP 5 3 IMGSNP Modifiers 5 3 P Imaging Style 5 3 B Beeper 5 3 T Wait for Trigger 5 4 L LED St...

Страница 9: ...put Image Height 5 25 D Pixel Depth 5 26 F File Format 5 26 H Height of Signature Capture Area 5 26 K Gamma Correction 5 27 R Resolution of Signature Capture Area 5 28 S Bar Code Aspect Ratio 5 28 W Width of Signature Capture Area 5 29 X Horizontal Bar Code Offset 5 29 Y Vertical Bar Code Offset 5 29 Chapter 6 Interface Keys KEYBOARD FUNCTION RELATIONSHIPS 6 1 SUPPORTED INTERFACE KEYS 6 3 SUPPORTE...

Страница 10: ...8 3 Concatenating Multiple Commands 8 3 Responses 8 4 Examples of Query Commands 8 4 TRIGGER COMMANDS 8 6 RESETTING THE CUSTOM DEFAULTS 8 6 MENU COMMANDS 8 7 Programming the Interfaces 8 7 Chapter 9 Maintenance REPAIRING 9 1 INSPECTING CORDS AND CONNECTORS 9 1 TROUBLESHOOTING 9 2 Chapter 10 Reference Charts SYMBOLOGY CHART 10 1 ASCII CONVERSION CHART CODE PAGE 1252 10 3 Non Printable Characters 10...

Страница 11: ...he following scanners NCR RealPOS Low Profile Bi Optic Scanner Scale 7874 NCR RealPOS High Performance Bi Optic Scanner Scale 7878 The Imaging Module is also available as a feature F150 for the NCR RealPOS Single Window Scanner 7884 This user guide provides demonstration installation and programming instructions for the NCR K150 F150 Imaging Module Specifications and dimensions information are als...

Страница 12: ...To connect the NCR K150 Imaging Module to the NCR 7874 Scanner refer to the NCR 7874 K150 Imaging Assembly Kit Instructions To connect the NCR K150 Imaging Module to the NCR 7878 Scanner refer to the NCR 7878 K150 Imaging Assembly Kit Instructions READING TECHNIQUES The NCR K150 F150 Imaging Module includes a view finder that projects a bright red aiming beam Follow the guidelines below to get a g...

Страница 13: ...anning numeric codes from the back cover then a Save code that entire sequence is saved to your custom defaults 3 Scan the Save Custom Defaults bar code below to save the commands for your custom defaults settings You can update or change a single command setting to your custom default setting Example To change the setting for Beeper Volume at Low to High 1 Scan the Set Custom Defaults bar code 2 ...

Страница 14: ...s the imaging module to the factory default settings Any settings not specified through the custom defaults is defaulted to the factory default settings RESETTING THE FACTORY DEFAULTS To erase all your settings reset the scanner to the original factory defaults and disable the plug ins follow the steps below 1 Scan the Remove Custom Defaults bar code below to erase your settings 2 Scan Activate De...

Страница 15: ... interface in effect USB IBM SurePos Scan one of the following Plug and Play codes to program the imaging module for an IBM SurePos USB handheld scanner or IBM SurePos USB tabletop scanner interface Note Power cycle the cash register after you scan one of these bar codes IBM SurePos USB Handheld Scanner IBM SurePos USB Tabletop Scanner Each bar code above also programs the following suffixes for e...

Страница 16: ...SB PC or Macintosh Keyboard Scan one of the following codes to program the imaging module for USB PC Keyboard or USB Macintosh Keyboard These codes also add a CR and LF USB Keyboard PC USB Keyboard Mac USB HID Scan the bar code below to program the imaging module for USB HID bar code scanners USB HID Bar Code Scanner ...

Страница 17: ...t Note If you are using a Microsoft Windows PC needs to be downloaded and installed The driver uses the next available COM Port number Note Apple Macintosh computers recognize the engine as a USB CDC class device and automatically uses a class driver USB Serial Note No extra configuration for example baud rate is necessary CTS RTS Emulation CTS RTS Emulation On CTS RTS Emulation Off ACK NAK Mode A...

Страница 18: ... Bi Optic Scanner This bar code programs the following baud rate and data format settings NCR Bi Optic Aux Port Configuration Scan the bar code below to program the imaging module for an NCR bi optic scanner auxiliary port configuration NCR Bi Optic Settings This bar code programs the following prefixes for each symbology Option Settings Baud Rate 9600 bps Data Format 8 data bits no parity 1 stop ...

Страница 19: ...d Two modes are available Normal and Enhanced Normal Mode Normal mode provides good scan speed and the longest working ranges depth of field Scan the bar code below to activate Normal mode Manual Trigger Normal Enhanced Mode Enhanced mode provides the highest possible scan speed but slightly less range than Normal mode Enhanced mode is best used when a very fast scan speed is required but a long w...

Страница 20: ...hen the LEDs become brighter to read the code If the light level in the room is not high enough Presentation Mode may not work properly Scan the bar code below to activate the Presentation Mode Presentation Mode Presentation LED Behavior after Decode When the scanner is in presentation mode the LEDs dim a few seconds after a barcode is decoded Scan the LEDs Off barcode below to dim the LEDs immedi...

Страница 21: ...r in this book scan the digit bar codes from 0 to 20 to set the sensitivity Note 0 is the most sensitive setting and 20 is the least sensitive The default sensitivity setting is 1 3 Refer to the Programming Chart section in the Samples and Programming Chart chapter in this book scan the Save bar code to save the new settings STREAMING PRESENTATION MODE In Streaming Presentation mode scan illuminat...

Страница 22: ...peed is required but a long working range is not required Streaming Presentation Mode Enhanced Note When using Preferred Symbology a lower priority symbol must be centered on the aiming pattern to be read in Streaming Presentation Mode Refer to the Preferred Symbology section in this chapter for further information Note The scanner cannot capture images when in Streaming Presentation Mode To take ...

Страница 23: ...o turn off Mobile Phone Read Mode scan a Manual Mode bar code IMAGE SNAP AND SHIP This mode permits the engine to take a picture rather than read a bar code when the trigger is pressed The imaging module ships the snapped picture to the host system as a jpeg file by default Scan the bar code below to activate the Image Snap and Ship mode Image Snap and Ship Note To revert to bar code reading chang...

Страница 24: ...ing Chart section in the Samples and Programming Chart chapter in this book scan the digit bar codes to set the time out duration Note The time out duration can be set from 0 to 300 000 milliseconds The time out default configuration is 5 000 ms 3 Refer to the Programming Chart section in the Samples and Programming Chart chapter in this book scan the Save bar code to save the new setting REREAD D...

Страница 25: ...ecific reread time delay 1 Scan the bar code below User Specified Reread Delay 2 Refer to the Programming Chart section in the Samples and Programming Chart chapter in this book scan the digit bar codes to set the time delay Note The reread delay ranges from 0 to 30 000 milliseconds 3 Refer to the Programming Chart section in the Samples and Programming Chart chapter in this book scan the Save bar...

Страница 26: ...ht The Aimer Mode sets the aiming light refer to the Aimer Mode section in this chapter for more information Lights On Lights Off AIMER DELAY This feature permits a time delay for the operator to aim the engine before a picture is taken Scan a bar code below to set the time duration between when the trigger is pulled and when the picture is taken Note During the time delay the aiming light appears...

Страница 27: ...y duration Note The aimer delay ranges from 0 to 4 000 ms 3 Refer to the Programming Chart section in the Samples and Programming Chart chapter in this book scan the Save bar code to save the new settings SCANNER TIME OUT This feature powers down the imaging module after the unit has been idle for a specified time 1 Scan the Scanner Time Out bar code below Scanner Time Out 2 Refer to the Programmi...

Страница 28: ...tructions 3 Refer to the Programming Chart section in the Samples and Programming Chart chapter in this book scan the Save bar code to save the new settings AIMER MODE This feature permits you to turn the aimer on or off The Interlaced bar code interlaces the aimer with the illumination LEDs Interlaced Off ...

Страница 29: ...near laser bar code scanners In the example below the gray area is the full imaging module field of view and the white area is the centering window The imaging module reads Bar Code 2 but does not read Bar code 1 The default centering window is a 169x128 pixel area in the center of the engine s field of view The following diagram illustrates the default top bottom left and right pixel positions me...

Страница 30: ...ature Centering On 2 Scan one of the following bar codes to change the top bottom left or right of the centering window Top of Centering Window Left of Centering Window Right of Centering Window Bottom of Centering Window 3 Refer to the Programming Chart section in the Samples and Programming Chart chapter in this book scan the digit bar codes to adjust the percent you want to shift the centering ...

Страница 31: ...e a Code 39 symbol as well as the PDF417 symbol you can use Preferred Symbology to specify that the PDF417 symbol be read instead of the Code 39 Preferred Symbology classifies each symbology as high priority low priority or an unspecified type When a low priority symbology is presented the imaging module ignores it for a set period of time while it searches for the high priority symbology If a hig...

Страница 32: ... Scan the Save bar code to save the selection Note There is no default selection for a High Priority Symbology Low Priority Symbology Follow the procedures below to specify a Low Priority Symbology 1 Scan the Low Priority Symbology bar code below Low Priority Symbology 2 Refer to the Symbology Chart section in the Reference Chart chapter in this book find the symbology to be set as low priority an...

Страница 33: ...bar code has been encountered Follow the procedures below to set the Preferred Symbology Time Out feature 1 Scan the Preferred Symbology Time Out bar code below Preferred Symbology Time Out 2 Refer to the Programming Chart section in the Samples and Programming Chart chapter in this book scan the digit bar codes to set the time delay before the feature times out Note The delay for the Preferred Sy...

Страница 34: ...the Alphanumeric symbols inside back cover to read these options Follow the procedures below to set the Output Sequence Editor 1 Scan the Enter Sequence bar code below Enter Sequence 2 Refer to the Symbology Chart section in the Reference Chart chapter in this book locate the desired symbology to be included in the output sequence format and take note of its 2 digit Hex value 3 Refer to the Progra...

Страница 35: ...uence 8 Once the sequence is complete you can perform the following Scan the Save bar code to save your selections or Scan the Discard bar code to exit without saving any Output Sequence changes Refer to the Programming Chart section in the Samples and Programming Chart chapter in this book for the Save and Discard bar codes 9 Scan the Default Sequence bar code below to program the imaging module ...

Страница 36: ... code identifier for Code 93 9999 code length that must match for Code 93 9999 all lengths 43 start character match for Code 93 43h C FF termination string for third code To program the previous example with specific lengths count any programmed prefixes suffixes or formatted characters as part of the length The sequence editor is set with the following command line SEQBLK62001241FF6A001342FF69001...

Страница 37: ...rd partial sequences Discard Partial Sequence or Scan the Transmit Partial Sequence bar code below to transmit partial sequences Transmit Partial Sequence Note The imaging module skips any fields in the sequence where no data match occurs Require Output Sequence Once the output sequence editor you can perform the following Scan the Required bar code below to require the output to follow a certain ...

Страница 38: ...ction is turned on Multiple Symbols This selection permits you to read multiple symbols with a single pull of the trigger If the scanner is aimed at a series of bar codes and trigger is pressed and held the imaging module reads unique symbols once and beeps if turned on for each read The imaging module attempts to find and decode new symbols as long as the trigger is pulled Scan a bar code below t...

Страница 39: ...ad feature On Off Note If you want a different notation than NR for example Error or Bad Code you can edit the output message refer to the Data Formatting chapter of this book The hex code for the No Read symbol is 9C VIDEO REVERSE This selection permits the imaging module to read bar codes that are inverted The Video Reverse Off bar code below is an example of this type of bar code The imaging mo...

Страница 40: ...ard Bar Code Scan the Video Reverse Off bar code below to turn off the video reverse feature and read only standard bar codes Video Reverse Off Note Once the Video Reverse Only bar code is scanned the imaging module can not read the menu bar codes Scan Video Reverse Off or Video Reverse and Standard Bar Codes in order to read the menu bar codes Note Images downloaded from the unit are not reversed...

Страница 41: ...Matrix 2 of 5 Chinese Sensible Han Xin Code Maxi Code Codabar MicroPDF 417 Codablock A MSI Codablock F NEC 2 of 5 Code 11 Postal Codes 2D Code 128 Postal Codes Linear Code 32 Pharmaceutical PARAF PDF417 Code 39 GSI DataBar International Code 93 QR Code Data Matrix Straight 2 of 5IATA two bar start stop EAN JAN 13 Straight 2 of 5 Industrial three bar start stop EAN JAN 18 TCIF Linked Code 39 TLC 39...

Страница 42: ...e imaging module to decode all the allowable symbologies All Symbologies On To decode a particular symbology scan the All Symbologies Off bar code below followed by the bar code that enables that particular symbology Note The All Symbologies On bar code does not enable 2D Postal Codes 2D Postal Codes are enabled separately All Symbologies Off ...

Страница 43: ...y those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 Follow the steps below to set a specific message value 1 Scan the appropriate bar code for a particular symbology 2 Refer to the Programming Chart section in the Samples and Programming Chart chapter in this book scan the digit ...

Страница 44: ...ar code below to enable all default settings for the Codabar symbology Default All Codabar Settings Codabar Start Stop Characters Start Stop characters identify the leading and trailing ends of the bar code The imaging module either transmit or not transmit Start Stop characters Scan the appropriate bar code below to permit the engine to transmit or not transmit Start Stop Characters Default Don t...

Страница 45: ...k Character This selection permits the imaging to read and transmit bar code data with or without a check character No Check Character Validate and Transmit This selection permits the imaging module to read only Codabar bar codes printed with a check character and transmit this character at the end of the scanned data Validate Modulo 16 and Transmit Validate but Don t Transmit This selection permi...

Страница 46: ...nt to a symbol having a D stop character In this case the imaging module omits the D characters and concatenates the two messages into one Scan a bar code below to turn on or off the Codebar Concatenation symbology Default Off On Off The Require bar code below prevents the imaging module from decoding a single D character Codabar symbol without its companion Require Note This selection has no effe...

Страница 47: ... Codabar Message Length Scan the appropriate bar code below to change the message length Note Refer to Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Minimum Message Length Maximum Message Length ...

Страница 48: ...RIETARY Use pursuant to Company Instructions CODE 39 Scan the Default All Code 39 settings below to program all the default settings for Code 39 Default All Code 39 Scan the appropriate bar code below to turn On or Off the Code 39 symbology Default On On Off ...

Страница 49: ...it or not transmit Code 39 Start and Stop Characters Default Don t Transmit Transmit Don t Transmit Code 39 Check Character The following are settings applicable for the Code 39 Check Character Default No Check Character No Check Character This selection permits the imaging to read and transmit bar code data with or without a check character No Check Character Validate and Transmit This selection ...

Страница 50: ...ith a check character but not transmit the check character with the scanned data Validate but Don t Transmit Code 39 Message Length Scan the appropriate bar code below to change the message length Note Refer to the Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 0 48 Minimum Default 0 Maximum Default 48 Minimum Message Length Maximum M...

Страница 51: ...bar codes that start with a space excluding the start and stop symbols and does not immediately transmit the data It deletes the first space from each data and stores the data in the order in which the bar codes are read The imaging module transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space Scan the appropriate bar code below to enable or di...

Страница 52: ...tical PARAF Italian pharmacies use the Code 32 Pharmaceutical which is a form of the Code 39 symbology This symbology is also known as PARAF Note Trioptic Code must be turned off while scanning Code 32 Pharmaceutical codes Scan the appropriate bar code below to enable or disable Code 32 Pharmaceutical Default Off On Off ...

Страница 53: ...od respectively Character pairs P through Y decode as 0 through 9 Scan the appropriate bar code below to enable or disable Full ASCII feature Default Full ASCII Off Full ASCII On Full ASCII Off NUL U DLE P SP SPACE 0 0 V PP W p P SOH A DC1 Q A 1 1 A A QQ a A q Q STX B DC2 R B 2 2 B B RR b B r R ETX C DC3 S C 3 3 C C SS c C s S EOT D DC4 T D 4 4 D D TT d D t T ENQ E NAK U E 5 5 E E UU e E u U ACK F...

Страница 54: ... Follow the steps below to select the appropriate code page 1 Scan the bar code below Code 39 Code Page 2 Refer to the Code Page Mapping of Printed Bar Codes section of Appendix A select the code page with which the bar codes were created 3 Refer to the Programming Chart section in the Samples and Programming Chart chapter in this book scan the value corresponding to appropriate bar code 4 Refer t...

Страница 55: ...the appropriate bar code below to enable or disable the Interleaved 2 of 5 symbology Default Interleaved 2 of 5 On Interleaved 2 of 5 Off Interleaved 2 of 5 On Interleaved 2 of 5 Check Digit The following are settings applicable for the Interleaved 2 of 5 Check Character Default No Check Digit No Check Digit This selection permits the imaging to read and transmit bar code data with or without a ch...

Страница 56: ...idate but Don t Transmit This selection permits the imaging module to read only Interleaved 2 of 5 bar codes printed with a check digit but not transmit the check digit with the scanned data Validate but Don t Transmit Interleaved 2 of 5 Message Length Scan the appropriate bar code below to change the message length Note Refer to Message Length Description on page for additional information Note M...

Страница 57: ...ult All NEC 2 of 5 Settings Scan the appropriate bar code below to turn on or off the NEC 2 of 5 symbology Default NEC 2 of 5 On NEC 2 of 5 Off NEC 2 of 5 On NEC 2 of 5 Check Digit The following are settings applicable for the NEC 2 of 5 Check Character Default No Check Digit No Check Digit This selection permits the imaging to read and transmit bar code data with or without a check digit No Check...

Страница 58: ...idate but Don t Transmit This selection permits the imaging module to read only Interleaved 2 of 5 bar codes printed with a check digit but not transmit the check digit with the scanned data Validate but Don t Transmit NEC 2 of 5 Message Length Scan the appropriate bar code below to change the message length Note Refer to Message Length Description on page for additional information Note Minimum a...

Страница 59: ...Y Use pursuant to Company Instructions CODE 93 Scan the bar code below to program all the default settings for Code 39 Default Code 93 On Default All Code 93 Settings Scan the appropriate bar code below to turn on or off the Code 93 symbology Code 93 Off Code 93 On ...

Страница 60: ...aracters it may be because the bar code being scanned was created using a code page that is different from the one the host program expects Follow the steps below to select the appropriate code page 1 Scan the bar code below Code 93 Code Page 2 Refer to the Symbology Chart section in the Reference Chart chapter in this book select the code page with which the bar codes were created 3 Refer to the ...

Страница 61: ... START STOP Scan the bar code below to program all the default settings for 2 of 5 Industrial settings Default All Straight 2 of 5 Industrial Settings Scan the appropriate bar code below to enable or disable Straight 2 of 5 Industrial Codes Default Straight 2 of 5 Industrial Off Straight 2 of 5 Industrial On Straight 2 of 5 Industrial Off ...

Страница 62: ...Straight 2 of 5 Industrial Message Length Scan the appropriate bar code below to change the message length Note Refer to Message Length Description on page for additional information Note Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Minimum Message Length Maximum Message Length ...

Страница 63: ...TRAIGHT 2 OF 5 IATA TWO BAR START STOP Scan the bar code below to program all the default settings for Straight 2 of 5 IATA codes Default All Straight 2 of 5 IATA Settings Scan the appropriate bar code below to enable or disable Straight 2 of 5 IATA codes Straight 2 of 5 IATA On Straight 2 of 5 IATA Off ...

Страница 64: ...ght 2 of 5 IATA Message Length Scan the appropriate bar code below to change the message length Note Refer to Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Minimum Message Length Maximum Message Length ...

Страница 65: ... Scan the bar code below to enable or disable Matrix 2 of 5 codes Default Matrix 2 of 5 Matrix 2 of 5 On Matrix 2 of 5 Off Matrix 2 of 5 Message Length Scan the appropriate bar code below to change the message length Note Refer to Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Minimum Message ...

Страница 66: ... for Code 11 Default All Code 11 Settings Scan the appropriate bar code below to enable or disable Code 11 Default Code11 Off Code 11 On Code 11 Off Check Digits Required This selection sets whether 1 or 2 check digits are required with Code 11 bar codes Scan a bar code below to set the number of required digits Default Two Check Digits One Check Digit Two Check Digits ...

Страница 67: ...tions Code 11 Message Length Scan the appropriate bar code below to change the message length Note Refer to Message Length Description of this chapter for additional information Note Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Страница 68: ...nternational Society of Blood Transfusion ISBT ratified a standard for communicating critical blood information in a uniform manner The use of ISBT formats requires a paid license The ISBT 128 Application Specification contains the following standards 1 The critical data elements for labeling blood products 2 The current recommendation to use Code 128 due to its high degree of security and its spa...

Страница 69: ...tion on or off Default 128 Concatenation Off 128 Concatenation On 128 Concatenation Off Code 128 Message Length Scan the appropriate bar code below to change the message length Note Refer to Message Length Description on page for additional information Note Minimum and Maximum lengths 0 90 Minimum Default 0 Maximum Default 90 Minimum Message Length Maximum Message Length ...

Страница 70: ...e Scan the appropriate bar code below to enable or disable the Code 39 Append feature Default Code 128 Append Off Code 128 Append On Code 128 Append Off Code 128 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from th...

Страница 71: ...nd Programming Chart chapter in this book scan the Save bar code to save the changes The data characters should then appear properly GS1 128 Scan the bar code below to program all the default settings for GS1 128 codes Default All GS1 128 Settings Scan the appropriate bar code below to enable or disable GS1 128 codes Default GS1 128 On GS1 128 On GS1 128 Off ...

Страница 72: ...GS1 128 Message Length Scan the appropriate bar code below to change the message length Note Refer to the Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Страница 73: ... All Telelpen Settings Scan the appropriate bar code below to enable or disable Telepen codes Default Telepen Off Telepen On Telepen Off Telepen Output The following are options applicable for the Telepen Output selection AIM Telepen Output This selection permits the engine to reads symbols with start stop pattern 1 and decode them as standard full ASCII start stop pattern 1 AIM Telepen Output ...

Страница 74: ...ern 1 and decode them as compressed numeric with optional full ASCII start stop pattern 2 Original Telepen Output Telepen Message Length Scan the appropriate bar code below to change the message length Note Refer to Message Length Description of this chapter for additional information Note Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 Minimum Message Length Maximum Message ...

Страница 75: ... UPC A Default All UPC A Settings Scan the appropriate bar code below to enable or disable UPC A codes UPC A On UPC A Off UPC A Check Digit This selection specifies whether the imaging module transmits the check digit at the end of the scanned data or not Scan the appropriate bar code below to permit the imaging module to transmit the check digit or not Default On On Off ...

Страница 76: ...stem digit is transmitted at the beginning of the scanned data Scan the appropriate bar code below to transmit or not transmit the UPC A numeric system digit Default On On Off UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data Scan the appropriate bar code below to add 2 or 5 digits to the end of all scanned UPC A data Default 2 Digit Addenda Off Digit Addenda Off...

Страница 77: ... UPC A Addenda Required This selection permits the engine to only read UPC A bar codes that have addenda Scan the appropriate bar code below to enable or disable UPC Addenda required Note Specify a 2 or 5 digit addenda once you enable this feature Refer to the UPC A Addenda section in this chapter Default Not Required Required Not Required ...

Страница 78: ... UPC A Addenda Separator This selection adds a space between the bar code data and the addenda data If this selection is disabled then there will be no space between the bar code data and addenda data Scan the appropriate bar code below to enable or disable the UPC A Addenda Separator Default On On Off ...

Страница 79: ...nd Extended Coupon Codes as single bar codes Off Allow Concatenation This selection permits the imaging module to transmit coupon codes and extended coupon codes as separate symbologies when it reads the codes in a single scan Otherwise the engine transmits the first coupon code it reads Allow Concatenation Require Concatenation This selection requires the engine to read the coupon code and extend...

Страница 80: ... P C bar codes lead with the 0 number system Scan the appropriate bar code below to read UPC E0 codes Default UPC E0 On UPC E0 On UPC E0 Off Note If you need to read codes that lead with the 1 number system refer to UPC E1 on page in this chapter UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default UPC E0 Off Scan the appropriate bar code below to enable or disabl...

Страница 81: ... Scan the appropriate bar code below to enable or disable UPC E0 Addenda Required Default Not Required Required Not Required UPC E0 Addenda Separator This selection adds a space between the bar code data and the addenda data If this selection is disabled then there will be no space between the bar code data and addenda data Scan the appropriate bar code below to enable or disable the UPC E0 Addend...

Страница 82: ...n the appropriate bar code below to permit the imaging module to transmit the check digit or not Default On On Off UPC E0 Number System This selection permits the imaging module to transmit or not transmit the numeric system digit of a UPC symbol Note The numeric system digit is transmitted at the beginning of the scanned data Scan the appropriate bar code below to transmit or not transmit the UPC...

Страница 83: ...PC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Scan the appropriate bar code below to add 2 or 5 digits to the end of all scanned UPC E data Default 2 Digit Addenda Off 5 Digit Addenda Off 2 digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off ...

Страница 84: ...code below to enable or disable UPC Addenda required Default Not Required Note Specify a 2 or 5 digit addenda once you enable this feature refer to the UPC A Addenda section of this chapter Required Not Required UPC E1 Scan the appropriate bar code below to enable or disable UPC E1 codes Default UPC E1 On Note Most UPC codes lead with the 0 number system For these codes refer to UPC E0 on page of ...

Страница 85: ...l EAN JAN Setting Scan the appropriate bar code below to enable or disable EAN JAN 13 codes Default EAN JAN 13 On EAN JAN 13 On EAN JAN 13 Off EAN JAN 13 Check Digit This selection specifies whether the imaging module transmits the check digit at the end of the scanned data or not Scan the appropriate bar code below to permit the imaging module to transmit the check digit or not Default On On Off ...

Страница 86: ... 13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Scan the appropriate bar code below to add 2 or 5 digits to the end of all scanned EAN JAN 13 data Default 2 Digit Addend Off 5 Digit Addenda Off 2 digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off ...

Страница 87: ...ed Default Not Required Required Not Required EAN JAN 13 Addenda Separator This selection adds a space between the bar code data and the addenda data If this selection is disabled then there will be no space between the bar code data and addenda data Scan the appropriate bar code below to enable or disable the EAN JAN 13 Addenda Separator Default On On Off Note If you want to enable or disable EAN...

Страница 88: ...13 Bookland symbols into their equivalent ISBN number format Scan a bar code below to enable or disable ISBN Translate Default Off On Off EAN JAN 8 Scan the bar code below to program all default settings for EAN JAN 8 EAN JAN 8 Scan the appropriate bar code below to enable or disable EAN JAN 8 codes Default EAN JAN 8 On EAN JAN 8 On EAN JAN 8 Off ...

Страница 89: ...ant to Company Instructions EAN JAN 8 Check Digit This selection permits the imaging module to transmit the check digit at the end of the scanned data or not Scan the appropriate bar code below to permit the imaging module to transmit the check digit or not Default On On Off ...

Страница 90: ...N 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Scan the appropriate bar code below to add 2 or 5 digits to the end of all scanned EAN JAN 8 data Default 2 Digit Addenda Off 5 Digit Addend Off 2 digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off ...

Страница 91: ...propriate bar code below to enable or disable EAN JAN 8 addenda required Default Not Required Required Not Required EAN JAN 8 Addenda Separator This selection adds a space between the bar code data and the addenda data If this selection is disabled then there will be no space between the bar code data and addenda data Scan the appropriate bar code below to enable or disable the EAN JAN 8 Addenda S...

Страница 92: ...I Off MSI Check Character MSI bar codes use different types of check characters The imaging module can be programmed to read MSI bar codes with Type 10 only or Type 10 and 11 check characters The following are settings applicable for MSI Check Character Validate Type 10 11 and Transmit This selection permits the imaging module to only read MSI bar codes printed with the specified type check charac...

Страница 93: ...ansmit This selection permits the engine to only read MSI bar codes printed with the specified type check character s but does not transmit the check character s with the scanned data Validate Type 10 but Don t Transmit Validate 2 Type 10 Characters but Don t Transmit Validate Type 10 then Type 11 Characters but Don t Transmit Disable MSI Check Characters This selection disables MSI check characte...

Страница 94: ...l information Note Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Minimum Message Length Maximum Message Length GS1 DATABAR OMNIDIRECTIONAL Scan the bar code below to program all the defaults settings for GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings Scan the appropriate bar code below to enable or disable GS1 DataBar Omnidirectional Codes Defa...

Страница 95: ...idirectional Off GS1 DATABAR LIMITED Scan the bar code below to program all default settings for GS1 DataBar Limited Default All GS1 DataBar Limited Settings Scan the appropriate bar code below to enable or disable GS1 DataBar Limited codes Default GS1 DataBar Limited On GS1 DataBar Limited On GS1 DataBar Limited Off ...

Страница 96: ...1 DATABAR EXPANDED Scan the bar code below to program all default settings for GS1 DataBar Expanded Default All GS1 DataBar Expanded Settings Scan the appropriate bar code below to enable or disable GS1 DataBar Expanded codes Default GS1 DataBar Expanded On GS1 DataBar Expanded On GS1 DataBar Expanded Off ...

Страница 97: ...n section of this chapter for additional information Note Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 Minimum Message Length Maximum Message Length TRIOPTIC CODE Use Trioptic Code for labeling magnetic storage media Note If you scan Code 32 Pharmaceutical codes disable Trioptic Code first Scan the appropriate bar code below to enable or disable Trioptic codes Default Trio...

Страница 98: ...uant to Company Instructions CODABLOCK A Scan the bar code below to program all default settings for Codablock A Default All Codablock A Settings Scan the appropriate bar code below to enable or disable Codablock A codes Default Codablock A Off Codablock A On Codablock A Off ...

Страница 99: ...ablock A Message Length Scan the appropriate bar code below to change the message length Note Refer to the Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 1 600 Minimum Default 1 Maximum Default 600 Minimum Message Length Maximum Message Length ...

Страница 100: ...uant to Company Instructions CODABLOCK F Scan the bar code below to program all default settings for Codablock F Default All Codablock F Settings Scan the appropriate bar code below to enable or disable Codablock F codes Default Codablock F Off Codablock F On Codablock F Off ...

Страница 101: ...block F Message Length Scan the appropriate bar code below to change the message length Note Refer to the Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 Minimum Message Length Maximum Message Length ...

Страница 102: ...OPRIETARY Use pursuant to Company Instructions PDF417 Scan the bar code below to program all default settings for PDF417 Default All PDF417 Settings Scan the appropriate bar code below to enable or disable PDF417 codes Default PDF417 On PDF417 On PDF417 Off ...

Страница 103: ...s PDF417 Message Length Scan the appropriate bar code below to change the message length Note Refer to the Message Length Description of this chapter for additional information Note Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 Minimum Message Length Maximum Message Length ...

Страница 104: ...uant to Company Instructions MICROPDF417 Scan the bar code below to program all default settings for MicroPDF417 Default All MicroPDF417 Settings Scan the appropriate bar code below to enable or disable MicroPDF417 codes Default MicroPDF417 Off MicroPDF417 On MicroPDF417 Off ...

Страница 105: ...roPDF417 Message Length Scan the appropriate bar code below to change the message length Note Refer to the Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 Minimum Message Length Maximum Message Length ...

Страница 106: ...s already in use Scan the appropriate bar code below to enable or disable GS1 Composite codes Default GS1 Composite Off GS1 Composite On GS1 Composite Off UPC EAN Version This selection decodes GS1 Composite symbols that have a U P C or an EAN linear component Note This does not affect GS1 Composite symbols with a GS1 128 or GS1 linear component Scan the appropriate bar code below to enable or dis...

Страница 107: ...osite Code Message Length Scan the appropriate bar code below to change the message length Note Refer to the Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 1 2435 Minimum Default 1 Maximum Default 2435 Minimum Message Length Maximum Message Length ...

Страница 108: ...can be simplified since it only needs to recognize one data carrier type The GS1 Emulation feature provides the following settings GS1 128 Emulation This selection expands all retail codes U P C UPC E EAN8 EAN13 to 16 digits If the AIM ID is enabled the value becomes the GS1 128 AIM ID C1 Refer to the Symbology Chart section in the Reference Chart chapter in this book GS1 128 Emulation GS1 DataBar...

Страница 109: ...and settings to control UPC E expansion If the AIM ID is enabled the value becomes the GS1 128 AIM ID C1 Refer to the Symbology Chart section in the Reference Chart chapter in this book GSI Code Expansion Off EAN8 to EAN13 Conversion This selection converts all EAN8 bar codes to EAN13 format EAN8 to EAN13 Conversion GS1Emulation Off This selection disable the GS1 Emulation settings GS1 Emulation O...

Страница 110: ...inear component and a MicroPDF417 stacked code component All scanners are capable of reading the Code 39 linear component however the scanners can only decode he MicroPDF417 component if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Scan the appropriate bar code below to enable or disable TCIF Linked Code 39 Default TLC39 Off TLC39 On TLC39 Off ...

Страница 111: ...y Instructions QR CODE Scan the bar code below to program all default settings for QR Code Default All QR Code Settings Scan the appropriate bar code below to enable or disable QR Code Default QR Code On Note This selection applies to both QR Code and Micro QR Code QR Code On QR Code Off ...

Страница 112: ... Code Message Length Scan the appropriate bar code below to change the message length Note Refer to the Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 1 7089 Minimum Default 1 Maximum Default 7089 Minimum Message Length Maximum Message Length ...

Страница 113: ...uant to Company Instructions DATA MATRIX Scan the bar code below to program all default settings for Data Matrix Default All Data Matrix Settings Scan the appropriate bar code below to enable or disable Data Matrix codes Default Data Matrix On Data Matrix On Data Matrix Off ...

Страница 114: ... the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program expects Follow the steps below to select the appropriate code page 1 Scan the bar code below Data Matrix Code Page 2 Refer to the Symbology Chart section in the Reference Chart chapter in this book select the code page with which the bar codes were creat...

Страница 115: ...ETARY Use pursuant to Company Instructions MAXICODE Scan the bar code below to program all default settings for MaxiCode Default All MaxiCode Settings Scan the appropriate bar code below to enable or disable MaxiCode Default MaxiCode On MaxiCode On MaxiCode Off ...

Страница 116: ...xiCode Message Length Scan the appropriate bar code below to change the message length Note Refer to the Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 Minimum Message Length Maximum Message Length ...

Страница 117: ...se pursuant to Company Instructions AZTEC CODE Scan the bar code below to program all default settings for Aztec Code Default All Aztec Code Settings Scan the appropriate bar code below to enable or disable Aztec Code Default Aztec Code On Aztec Code On Aztec Code Off ...

Страница 118: ... proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program expects Follow the steps below to select the appropriate code page 1 Scan the bar code below Data Matrix Code Page 2 Refer to the Symbology Chart section in the Reference Chart chapter in this book select the code page with which the bar codes were created 3...

Страница 119: ... Instructions CHINESE SENSIBLE HAN XIN CODE Scan the bar code below to program all default settings for Chinese Sensible HAN XIN Code Default All Han Xin Settings Scan the appropriate bar code below to enable or disable Han Xin Code Default Han Xin Code Off Han Xin Code On Han Xin Code Off ...

Страница 120: ...in Code Message Length Scan the appropriate bar code below to change the message length Note Refer to the Message Length Description section of this chapter for additional information Note Minimum and Maximum lengths 1 7883 Minimum Default 1 Maximum Default 7883 Minimum Message Length Maximum Message Length ...

Страница 121: ...lists the possible 2D postal codes and 2D postal code combinations that are permitted Only one 2D postal code selection can be active at a time A second scan of a 2D postal code selection overwrites the first selection Scan the 2D Postal Codes Off bar code below to disable Postal Codes Default 2D Postal Codes Off 2D Postal Codes Off ...

Страница 122: ... CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions Single 2D Postal Codes Australian Post On Britsh Post On Canadian Post On Intelligent Mail Bar Code On Japanese Post On KIX Post On Planet Code On Postal 4i On Postnet On ...

Страница 123: ...any Instructions Combination 2D Postal Codes Infomail and British Post On Intelligent Mail Bar Code and Postnet with B and B Fields On Postnet and Postal 4i On Postnet and Intelligent Mail Bar Code On Postal 4i and Intelligent Mail Bar Code On Postnet with B and B Fields On InfoMail On ...

Страница 124: ...nstructions Postal 4i and Postnet with B and B Fields On Planet Code and Postnet On Planet Code and Postnet with B and B Fields On Planet Code and Postal 4i On Planet Code and Intelligent Mail Bar Code On Planet Code Postnet and Postal 4i Planet Code Postnet and Intelligent Mail Bar Code On ...

Страница 125: ...and Intelligent Mail Bar Code On Planet Code Postal 4i and Postnet with B and B Fields On Planet Code Intellligent Mail Bar Code and Postnet with B and B Fields On Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On Planet Code Postal 4i Intelligent Mail Bar Code and Postnet Planet Code Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On ...

Страница 126: ... below to permit the imaging module to transmit the check digit or not Default Don t Transmit Check Digit Transmit Check Digit Don t Transmit Check Digit Postnet Check Digit This selection specifies whether the imaging module transmits the check digit at the end of the scanned data or not Scan the appropriate bar code below to permit the imaging module to transmit the check digit or not Default Do...

Страница 127: ...ar postal code selections can be active at a time Default China Post Hong Kong 2 of 5 Off China Post Hong Kong 2 of 5 Scan the bar code below to program all default settings for China Post Hong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings Scan the appropriate bar code below to enable or disable Hong Kong 2 of 5 Code China Post Hong Kong 2 of 5 On China Post Hong Kong 2 of 5 Off ...

Страница 128: ...age Length Description section of this chapter for additional information Note Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Minimum Message Length Maximum Message Length Korea Post Scan the bar code below to program all default settings for Korea Post Default All Korea Post Settings Scan the appropriate bar code below to enable or disable Korea Post codes Default Korea Pos...

Страница 129: ...dditional information Note Minimum and Maximum lengths 2 80 Minimum Default 2 Maximum Default 48 Minimum Message Length Maximum Message Length Korea Post Check Digit This selection specifies whether the imaging module transmits the check digit at the end of the scanned data or not Scan the appropriate bar code below to permit the imaging module to transmit the check digit or not Default Don t Tran...

Страница 130: ...Symbologies 4 90 B005 0000 2166 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions ...

Страница 131: ...aging module performs these functions Single Use Basis Imaging Commands with their modifiers send instructions to the imaging module on a single use basis and take effect for a single image capture Once that capture is complete the imaging module reverts to its imaging default settings To permanently change a setting use the serial default commands refer to the Serial Programming Commands section ...

Страница 132: ...o a sequence is separated with a semicolon Example To add the Image Ship command to the above sequence enter IMGSNP1P1T IMGSHP The following are the imaging commands for the imaging module Image Snap IMGSNP Image Ship IMGSHP Intelligent Signature Capture IMGBOX The modifiers for each of these commands follow the command description Note The images included with each command description are example...

Страница 133: ... The following command snaps an image increases the gain and permits the beeper to sound once the snap is complete IMGSNP2G1B IMGSNP Modifiers P Imaging Style This modifier sets the Image Snap style 0P Decoding Style This style permits a few frames to be taken until the exposure parameters are met The last frame is then available for further use 1P Photo Style default This style mimics a simple di...

Страница 134: ...ault Use this state for pictures of color documents such as ID cards especially when the scanner is in a stand 1L LED Illumination LEDs On Use this state when the scanner is handheld Note LED State is not available when Decoding Style 0P is used E Exposure This modifier sets the exposure time similar to a shutter speed setting on a camera The exposure time determines how long the imaging module ta...

Страница 135: ... CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions The following are examples of images captured at a set exposure time Exposure time set at 7874E with flourescent lighting Exposure time set at 100E with flourescent lighting ...

Страница 136: ... captured images The Exposure setting affects the results when Gain is used As the gain increases the noise in an image is also amplified 1G No gain default 2G Medium gain 4G Heavy gain 8G Maximum gain Note Gain is only available in Manual Style 2P The following are examples of images set at a specific Gain Gain at 1G Gain at 4G Gain at 8G ...

Страница 137: ... result in longer exposure times and brighter images but if the setting is too high the image may be overexposed Default 125 Note Target White Value is only available when using Photo Style 1P nW Range n is 0 to 255 The following are examples of images captured at a specific White Value White Value at 75W White Value at 125W White Value at 200W D Delta for Acceptance This modifier sets the allowab...

Страница 138: ...er sets the target point for the light and dark values in the captured image A setting of 75 means 75 of the pixels are at or below the target white value and 25 of the pixels are above the target white value Altering this setting from the default is not recommended under normal circumstances To alter grayscale values use W Target White Value Default 50 n Range n is 1 to 99 The following are examp...

Страница 139: ...lways begin with a number and end with a letter which is case insensitive Any number of modifiers may be appended to the IMGSHP command Example The following command snaps and ships a bitmap image with gamma correction and document image filtering IMGSNP IMGSHP8F75K26U IMGSHP Modifiers A Infinity Filter This modifier enhances pictures captured from very long distances greater than 10 feet or 3m No...

Страница 140: ...umination across the image 0C Compensation disabled default 1C Compensation enabled The following images compares the output between Compensation is enabled and disabled Compensation Disabled Compensation Enabled D Pixel Depth This modifier indicates the number of bits per pixel in the transmitted image KIM or BMP format only 8D 8 bits per pixel grayscale image default 1D 1 bit per pixel black and...

Страница 141: ... be entered from 1 to 24 Entering a 23E gives the sharpest edges but also increases noise in the image 0E Doesn t sharpen image default 14E Applies edge sharpen for typical image nE Range n is 1 to 24 The following images compare an output without Edge Sharpen and with a set Edge Sharpen Edge Sharpen at 0E Edge Sharpen at 24E F File Format This modifier ndicates the desired format for the image 0F...

Страница 142: ...F TIFF color compressed image 11F TIFF color uncompressed image 12F JPEG color image 14F BMP color format 15F BMP Uncompressed raw image H Histogram Stretch This modifier increases the contrast of the transmitted image Note This modifier is not available with some image formats 0H No stretch default 1H Histogram stretch The following images compare an output with Histogram Stretch disabled and ena...

Страница 143: ...uctions I Invert Image This modifier rotates the image around the X or Y axis 1ix Invert around the X axis flips picture upside down 1iy Invert around the Y axis flips picture left to right The following images are examples of an output being inverted Original Image Invert off Invert Image set to 1ix ...

Страница 144: ...rt Image Set to 1iy IF Noise Reduction This modifier reduces the salt and pepper noise in an image 0if No salt and pepper noise reduction default 1if Salt and pepper noise reduction The following images compare the output when Noise Reduction is disabled and enabled Noise Reduction Off 0if Noise Reduction On 1if ...

Страница 145: ... Rotate 0ir Image as snapped right side up default 1ir Rotate image 90 degrees to the right 2ir Rotate image 180 degrees upside down 3ir Rotate image 90 degrees to the left The following images are examples of output set to Image Rotate settings Image Rotate set to 0ir Image Rotate set to 1ir Image Rotate set to 2ir ...

Страница 146: ...ller files Default 50 0J worst quality smallest file 100J best quality largest file nJ Image is compressed as much as possible while preserving quality factor of n n 0 to100 K Gamma Correction Gamma measures the brightness of midtone values produced by the image Gamma Correction brightens or darkens an image A higher gamma correction yields an overall brighter image The lower the setting the darke...

Страница 147: ... 17 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions The following images compare output with a specified Gamma Correction Setting Gamma correction set to 0K Gamma Correction set to 50K Gamma Correction Set to 225K ...

Страница 148: ...on of this chapter nL The left edge of the shipped image corresponds to column n of the image in memory Range n 000 to 640 Default 0 nR The right edge of the shipped image corresponds to column n 1 of the image in memory Range n 000 to 640 Default all columns nT The top edge of the shipped image corresponds to row n of the image in memory Range n 000 to 480 Default 0 nB The bottom edge of the ship...

Страница 149: ...f the image data being sent to the host It addresses the protocol used to send the data Hmodem which is an Xmodem 1K variant that has additional header information and the format of the image data that is sent 0P None raw data 2P None default for USB 3P Hmodem compressed default for RS232 4P Hmodem S Pixel Ship This modifier sizes an image in proportion to its original size It decimates the image ...

Страница 150: ...tion refer to the K Gamma Correction section of this chapter With the scanner in a stand Image captured using the command IMGSNP1P0L168W90 32D This filter typically provides better JPEG compression than the standard E Edge Sharpen command This filter also works well when shipping pure black and white images 1 bit per pixel The optimal setting is 26U 0U Document image filter off default 26 UApply d...

Страница 151: ...ument Image Filter setting Document Image Filter set to 0U Document Filter set to 26U V Blur Image This modifier smooths transitions by averaging the pixels next to the hard edges of defined lines and shaded areas in an image 0V Don t blur default 1V Blur The following images compare outputs with Blur Image enabled and disabled Blur Image off 0V Blur Image On 1V ...

Страница 152: ...he highlights and an average key image has detail concentrated in the midtones This modifier ships the histogram for an image 0W Don t ship histogram default 1W Ship histogram The following is an example of a Histogram of taken from an image Histogram of image below Image used for the histogram Image Size Compatibility If you have applications that expect an image ship to return exactly 640x480 pi...

Страница 153: ...rea is from the bar code vertically and horizontally You can also set the resolution and file format for the final output of the signature capture image Only the following are the types of bar codes that can trigger IMGBOX commands PDF417 Code 39 Code 128 Aztec Codabar Interleaved 2 of 5 Once one of these symbologies has been read the imaging module retains the image for a possible IMGBOX command ...

Страница 154: ...an image to the host IMGBOX command IMGBOX245w37h55y Note Case is not important in the command string It is used here only for clarity 5 The engine captures the following image Use the different modifiers of the image ship commands have many different to change the quality of the image output Intelligent signature capture modifiers affect the image that is transmitted but do not affect the image i...

Страница 155: ...s used set the resolution R to zero The following are examples of images with a specified Image Width setting Image Width set to 200A Image Width set to 600A B Output Image Height This modifier adjusts the size of the image vertically If this modifier is used set the resolution R to zero The following are examples of images with a specified Output Image Height setting Image Height set to 50B Image...

Страница 156: ... Format This option indicates the type of file format in which to save the image 0F KIM format 1F TIFF binary 2F TIFF binary group 4 compressed 3F TIFF grayscale 4F Uncompressed Binary 5F Uncompressed grayscale 6F JPEG image default 7F Outlined image 8F BMP format H Height of Signature Capture Area The height of the signature capture area must be measured in inches divided by 01 In the example see...

Страница 157: ...higher gamma correction yields an overall brighter image The lower the setting the darker the image The optimal setting for text images is 50K 0K Gamma correction off default 50K Apply gamma correction for brightening typical document image nK Apply gamma correction factor n n 0 1000 The following are examples of images with a specified Gamma Correction setting Gamma Correction set to 0K Gamma Cor...

Страница 158: ... a resolution of 2 5 Note Set this modifier to zero when using the A and B modifiers Refer to the A Output Image Width and B Output Image Height sections of this chapter The following are examples of images with a specified Resolution value Resolution set to 0R Resolution set to 1000R Resolution set to 2000R S Bar Code Aspect Ratio All dimensions used in IMGBOX are measured as multiples of the min...

Страница 159: ...nter of the signature capture area Positive values move the horizontal center to the right and negative values to the left Measurements are in multiples of the minimum bar width The following are examples of images with a specified Horizontal Offset setting Horizontal Offset set to 75X Horizontal Offset set to 75X Y Vertical Bar Code Offset This modifier offsets the vertical center of the signatur...

Страница 160: ...Imaging Commands 5 30 B005 0000 2166 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions ...

Страница 161: ...ction Code Hex ASCII Value and Full ASCII CTRL relationships apply to all terminals that can be used with the engine Function Code HEX ASCII Value Full ASCII CTRL NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1...

Страница 162: ... CTRL column 6 apply to US only The following chart indicates the equivalents of these five characters for different countries GS 1D RS 1E US 1F _ Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany à 6 Italy 6 Switzerland 6 United Kingdom 6 Denmark 8 9 6 Norway 8 9 6 Spain 6 Function Code HEX ASCII Value Full ASCII CTRL ...

Страница 163: ...break Reserved F15 BEL 07 CR Enter CR Enter New Line BS 08 Reserved Reserved F16 HT 09 Tab Tab F17 LF 0A Reserved Reserved F18 VT 0B Tab Tab Tab Field Forward FF 0C Delete Delete Delete CR 0D CR Enter CR Enter Field Exit New Line SO 0E Insert Insert Insert SI 0F Escape Escape F19 DLE 10 F11 Reserved Error Reset DC1 11 Home Home Home DC2 12 Print Print F20 DC3 13 Back Space Back Space Back Space DC...

Страница 164: ...ld Forward HT 09 F17 Field Forward LF 0A F18 Reserved VT 0B Tab Field Forward Field Forward FF 0C Delete Delete CR 0D Field Exit New Line SO 0E Insert Insert SI 0F Clear Erase DLE 10 Error Reset Error Reset DC1 11 Home Reserved DC2 12 Print Print DC3 13 Back Space Back Space DC4 14 Back Tab Back Field NAK 15 F19 Reserved SYN 16 F1 PF1 ETB 17 F2 PF2 CAN 18 F3 PF3 EM 19 F4 PF4 SUB 1A F5 PF5 ESC 1B F...

Страница 165: ...N A ENQ 05 N A N A N A ACK 06 N A N A N A BEL 07 New Line New Line New Line BS 08 N A N A N A HT 09 Tab Tab Tab LF 0A N A N A N A VT 0B Tab Tab Tab FF 0C N A N A Delete CR 0D New Line New Line New Line SO 0E N A N A Insert SI 0F Escape Escape Escape DLE 10 F11 F11 F11 DC1 11 Insert Insert Home DC2 12 F13 F13 Print DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Back Tab NAK 15 F12...

Страница 166: ...d Enter STX 02 CAPS ETX 03 ALT make EOT 04 ALT break ENQ 05 CNTRL make ACK 06 CNTRL break BEL 07 RETURN BS 08 APPLE make HT 09 TAB LF 0A APPLE break VT 0B TAB FF 0C Del CR 0D RETURN SO 0E Ins Help SI 0F ESC DLE 10 F11 DC1 11 Home DC2 12 Prnt Scrn DC3 13 BACKSPACE DC4 14 LSHIFT TAB NAK 15 F12 SYN 16 F1 ETB 17 F2 CAN 18 F3 EM 19 F4 SUB 1A F5 ESC 1B F6 FS 1C F7 GS 1D F8 RS 1E F9 US 1F F10 DEL 7F BACK...

Страница 167: ...ology Refer to the Symbology Chart section in the Reference Chart chapter in this book for the single character code that identifies each symbology This action first clears all current prefixes then programs a Code I D prefix for all symbologies This is a temporary setting that will be removed when the unit is power cycled Add Code I D Prefix to All Symbologies SHOW DECODER REVISION Scan the bar c...

Страница 168: ... capture Scan the bar code below to output the scan driver revision Show Scan Driver Revision SHOW SOFTWARE REVISION Scan the bar code below to output the current software revision unit serial number and other product information for the engine Show Revision SHOW DATA FORMAT Scan the bar code below to show current data format settings Data Format Settings ...

Страница 169: ...he programming function still occurs but in addition the content of that programming code is output to the terminal Note Do not use this feature during normal engine operation Scan the appropriate bar code below to enable or disable Test Menu Default Off Test Menu On Test Menu Off TOTALFREEDOM TotalFreedom is an open system architecture that provides the possibility to create applications that res...

Страница 170: ...d Applications are stored in groups Decoding and Formatting Scan the group s bar code below to enable or disable the applications in that group Default Apps On Formatting Apps On Decoding Apps On Decoding Apps Off Formatting Apps On Formatting Apps Off Scan the bar code below to generate a list of all the applications List Apps Note Reset the device in order for the application settings to take ef...

Страница 171: ...ay the bar code data in a window Scan Data sends serial commands to the engine and receive a response that is seen in the Scan Data window The data displayed in the Scan Data window is either saved in a file or printed Configure Configure displays the programming and configuration data of the engine The engine s programming and configuration data is grouped into different categories Each category ...

Страница 172: ...Under the Resources tab select Software 3 On the drop down menu for Select Product Number select Xenon 4 Select the listing for EZConfig 5 When prompted select Save File and save the files to the c windows temp directory 6 Once you have finished downloading the file exit the web site 7 Using Explorer go to c windows temp file 8 Double click on the Setup exe file 9 Follow the screen prompts to inst...

Страница 173: ...nd examples of each serial programming command refer to the corresponding programming bar code in this manual The device must be set to an RS232 interface The following commands are sent via a PC COM port using terminal emulation software Conventions The following conventions are used for menu and query command descriptions parameter A label representing the actual value you should send as part of...

Страница 174: ... are identified with a Tag of 232 SubTag A 3 character case insensitive field that identifies the desired menu command within the tag group For example the SubTag for the RS 232 baud rate is BAD Data The new value for a menu setting identified by the Tag and SubTag Storage A single character that specifies the storage table to which the command is applied An exclamation point performs the command ...

Страница 175: ...the command In this case do not use the SubTag and Data fields because they are ignored by the device Using SubTag Field When a query is used in place of a SubTag field the query applies only to the subset of commands available that match the Tag field In this case do not use the Data field because it is ignored by the device Using Data Field When a query is used in place of the Data field the que...

Страница 176: ...nserted directly before each of the following punctuation marks in the command Period Exclamation point Comma Semicolon Examples of Query Commands In the following examples a bracketed notation depicts a non displayable response Example What is the range of possible values for Codabar Coding Enable Select cbrena Response CBRENA0 1 ACK This response indicates that Codabar Coding Enable CBRENA has a...

Страница 177: ... ACK CK20 ACK CCT1 ACK MIN2 ACK MAX60 ACK DFT ACK This response indicates the following settings Codabar Coding Enable CBRENA is set to 1 or on Start Stop Character SSX is set to 0 or Don t Transmit Check Character CK2 is set to 0 or Not Required Concatenation CCT is set to 1 or Enabled Minimum Message Length MIN is set to 2 characters Maximum Message Length MAX is set to 60 characters Default set...

Страница 178: ...gine reads a bar code The engine receives the deactivate command The engine reaches the serial time out has been Refer to the Time Out section of Chapter 3 RESETTING THE CUSTOM DEFAULTS This selection resets the engine to the custom default settings If there are no custom defaults it resets the engine to the factory default settings Any settings that have not been specified through the custom defa...

Страница 179: ...tom Defaults DEFOVR 1 4 Activate Defaults DEFALT 1 4 Programming the Interface Plug and Play Codes IBM SurePos USB IBM SurePos Handheld PAPSPH 2 1 USB IBM SurePos Tabletop PAPSPT 2 1 Plug and Play Codes USB USB Keyboard PC PAP124 2 2 USB Keyboard Mac PAP125 2 2 USB HID PAP131 2 2 CTS RTS Emulation On USBCTS1 2 3 CTS RTS Emulation Off USBCTS0 2 3 ACK NAK Mode On USBACK1 2 3 ACK NAK Mode Off USBACK0...

Страница 180: ...age Snap and Ship Image Snap and Ship TRGMOD6 3 5 Hands Free Time Out Range 0 300 000 ms TRGPTO 3 6 Reread Delay Short 500 ms DLYRRD500 3 6 Medium 750 ms DLYRRD750 3 7 Long 1000 ms DLYRRD1000 3 7 Extra Long 2000 ms DLYRRD2000 3 7 User Specified Reread Delay Range 0 30 000 ms DLYRRD 3 7 Illumination Lights Lights On SCNLED1 3 8 Lights Off SCNLED0 3 8 Aimer Delay 200 milliseconds SCNDLY200 3 8 400 m...

Страница 181: ... 14 Preferred Symbology Timeout 500 Range 100 3000 PRFPTO 3 15 Preferred Symbology Default PRFDFT 3 15 Output Sequence Editor Enter Sequence SEQBLK 3 16 Default Sequence SEQDFT 3 17 Partial Sequence Transmit Partial Sequence SEQTTS1 3 19 Discard Partial Sequence SEQTTS0 3 19 Require Output Sequence Required SEQ_EN2 3 19 On and Not Required SEQ_EN1 3 20 Off SEQ_EN0 3 20 Multiple Symbols On SHOTGN1 ...

Страница 182: ...bar Concatenation Off CBRCCT0 4 6 On CBRCCT1 4 6 Require CBRCCT2 4 6 Codabar Message Length Minimum 2 60 4 CBRMIN 4 7 Maximum 2 60 60 CBRMAX 4 7 Code 39 Default All Code 39 Settings C39DFT 4 8 Off C39ENA0 4 8 On C39ENA1 4 8 Code 39 Start Stop Char Don t Transmit C39SSX0 4 9 Transmit C39SSX1 4 9 Code 39 Check Char No Check Char C39CK20 4 9 Validate But Don t Transmit C39CK21 4 9 Validate and Transm...

Страница 183: ... 2 80 80 I25MAX 4 16 NEC 2 of 5 Default All NEC 2 of 5 Settings N25DFT 4 17 Off N25ENA0 4 17 On N25ENA1 4 17 NEC 2 of 5 Check Digit No Check Char N25CK20 4 17 Validate But Don t Transmit N25CK21 4 18 Validate and Transmit N25CK22 4 18 NEC 2 of 5 Message Length Minimum 2 80 4 N25MIN 4 18 Maximum 2 80 80 N25MAX 4 18 Code 93 Default All Code 93 Settings C93DFT 4 19 Off C93ENA0 4 19 On C93ENA1 4 19 Co...

Страница 184: ...5ENA0 4 25 On X25ENA1 4 25 Matrix 2 of 5 Message Length Minimum 1 80 4 X25MIN 4 25 Maximum 1 80 80 X25MAX 4 25 Code 11 Default All Code 11 Settings C11DFT 4 26 Off C11ENA0 4 26 On C11ENA1 4 26 Code 11 Check Digits Required 1 Check Digit C11CK20 4 26 2 Check Digits C11CK21 4 26 Code 11 Message Length Minimum 1 80 4 C11MIN 4 27 Maximum 1 80 80 C11MAX 4 27 Code 128 Default All Code 128 Settings 128DF...

Страница 185: ...LMAX 4 34 UPC A Default All UPC A Settings UPADFT 4 35 Off UPAENA0 4 35 On UPAENA1 4 35 UPC A Check Digit Off UPACKX0 4 35 On UPACKX1 4 35 UPC A Number System Off UPANSX0 4 36 On UPANSX1 4 36 UPC A 2 Digit Addenda Off UPAAD20 4 36 On UPAAD21 4 36 UPC A 5 Digit Addenda Off UPAAD50 4 37 On UPAAD51 4 37 UPC A Addenda Required Not Required UPAARQ0 4 37 Required UPAARQ1 4 37 UPC A Addenda Separator Off...

Страница 186: ... UPC E1 Off UPEEN10 4 44 On UPEEN11 4 44 EAN JAN 13 Default All EAN JAN Settings E13DFT 4 45 Off E13ENA0 4 45 On E13ENA1 4 45 EAN JAN 13 Check Digit Off E13CKX0 4 45 On E13CKX1 4 45 EAN JAN 13 2 Digit Addenda 2 Digit Addenda On E13AD21 4 46 2 Digit Addenda Off E13AD20 4 46 5 Digit Addenda On E13AD51 4 46 5 Digit Addenda Off E13AD50 4 46 EAN JAN 13 Addenda Required Not Required E13ARQ0 4 47 Require...

Страница 187: ...4 52 MSI Check Character Validate Type 10 but Don t Transmit MSICHK0 4 53 Validate Type 10 and Transmit MSICHK1 4 52 Validate 2 Type 10 Chars but Don t Transmit MSICHK2 4 53 Validate 2 Type 10 Chars and Transmit MSICHK3 4 53 Validate Type 10 then Type 11 Char but Don t Transmit MSICHK4 4 53 Validate Type 10 then Type 11 Char and Transmit MSICHK5 4 53 Disable MSI Check Characters MSICHK6 4 53 MSI M...

Страница 188: ...block A Default All Codablock A Settings CBADFT 4 58 Off CBAENA0 4 58 On CBAENA1 4 58 Codablock A Msg Length Minimum 1 600 1 CBAMIN 4 59 Maximum 1 600 600 CBAMAX 4 59 Codablock F Default All Codablock F Settings CBFDFT 4 60 Off CBFENA0 4 60 On CBFENA1 4 60 Codablock F Msg Length Minimum 1 2048 1 CBFMIN 4 61 Maximum 1 2048 2048 CBFMAX 4 61 PDF417 Default All PDF417 Settings PDFDFT 4 62 On PDFENA1 4...

Страница 189: ... EANEMU3 4 69 EAN8 to EAN13 Conversion EANEMU4 4 69 GS1 Emulation Off EANEMU0 4 69 TCIF Linked Code 39 On T39ENA1 4 70 Off T39ENA0 4 70 QR Code Default All QR Code Settings QRCDFT 4 71 On QRCENA1 4 71 Off QRCENA0 4 71 QR Code Msg Length Minimum 1 7089 1 QRCMIN 4 72 Maximum 1 7089 7089 QRCMAX 4 72 Data Matrix Default All Data Matrix Settings IDMDFT 4 73 On IDMENA1 4 73 Off IDMENA0 4 73 Data Matrix ...

Страница 190: ...an Xin Code Settings HX_DFT 4 79 On HX_ENA1 4 79 Off HX_ENA0 4 79 Chinese Sensible Han Xin Code Msg Length Minimum 1 7833 1 HX_MIN 4 80 Maximum 1 7833 7833 HX_MAX 4 80 Postal Codes 2D 2D Postal Codes Off POSTAL0 4 81 Single 2D Postal Codes Australian Post On POSTAL1 4 82 British Post On POSTAL7 4 82 Canadian Post On POSTAL30 4 82 Intelligent Mail Bar Code On POSTAL10 4 82 Japanese Post On POSTAL3 ...

Страница 191: ...nfoMail and British Post On POSTAL8 4 83 Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL20 4 83 Postnet and Postal 4i On POSTAL14 4 83 Postnet and Intelligent Mail Bar Code On POSTAL16 4 83 Postal 4i and Intelligent Mail Bar Code On POSTAL17 4 83 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Страница 192: ...POSTAL22 4 84 Planet Postal 4i and Intelligent Mail Bar Code On POSTAL23 4 85 Postnet Postal 4i and Intelligent Mail Bar Code On POSTAL24 4 85 Planet Postal 4i and Postnet with B and B Fields On POSTAL25 4 85 Planet Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL26 4 85 Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL27 4 85 Planet Postal 4i Intelli...

Страница 193: ...7 Off CPCENA0 4 87 On CPCENA1 4 87 China Post Hong Kong 2 of 5 Msg Length Minimum 2 80 4 CPCMIN 4 88 Maximum 2 80 80 CPCMAX 4 88 Korea Post Default All Korea Post Settings KPCDFT 4 88 Off KPCENA0 4 88 On KPCENA1 4 88 Korea Post Msg Length Minimum 2 80 4 KPCMIN 4 89 Maximum 2 80 48 KPCMAX 4 89 Korea Post Check Digit Transmit Check Digit KPCCHK1 4 89 Don t Transmit Check Digit KPCCHK0 4 89 Imaging D...

Страница 194: ...Wait for Trigger Off SNPTRG0 5 4 Wait for Trigger On SNPTRG1 5 4 LED State Off SNPLED0 5 4 LED State On SNPLED1 5 4 Exposure 1 7874 microseconds SNPEXP 5 4 Gain None SNPGAN1 5 6 Gain Medium SNPGAN2 5 6 Gain Heavy SNPGAN4 5 6 Gain Maximum SNPGAN8 5 6 Image Snap Continued Target White Value 0 255 125 SNPWHT 5 7 Delta for Acceptance 0 255 25 SNPDEL 5 7 Update Tries 0 10 6 SNPTRY 5 8 Target Set Point ...

Страница 195: ...le Format JPEG IMGFMT6 5 11 File Format KIM IMGFMT0 5 11 File Format TIFF binary IMGFMT1 5 11 File Format TIFF binary group 4 compressed IMGFMT2 5 11 File Format TIFF grayscale IMGFMT3 5 11 File Format Uncompressed binary IMGFMT4 5 11 File Format Uncompressed grayscale IMGFMT5 5 12 File Format BMP IMGFMT8 5 12 Histogram Stretch Off IMGHIS0 5 12 Histogram Stretch On IMGHIS1 5 12 Noise Reduction Off...

Страница 196: ...Image Crop Top 0 480 0 IMGWNT 5 18 Image Crop Bottom 0 480 479 IMGWNB 5 18 Image Crop Margin 1 238 0 IMGMAR 5 18 Protocol None raw IMGXFR0 5 19 Protocol None default USB IMGXFR2 5 19 Protocol Hmodem Compressed IMGXFR3 5 19 Protocol Hmodem IMGXFR4 5 19 Ship Every Pixel IMGSUB1 5 19 Ship Every 2nd Pixel IMGSUB2 5 19 Ship Every 3rd Pixel IMGSUB3 5 19 Document Image Filter Off IMGUSH0 5 20 Document Im...

Страница 197: ...166 8 25 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions Intelligent Signature Capture Optimize On DECBND1 5 23 Optimize Off DECBND0 5 23 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Страница 198: ...Serial Programming Commands 8 26 B005 0000 2166 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions ...

Страница 199: ...r upgrades on this product Only authorized service centers perform these services Contact NCR Support for technical assistance INSPECTING CORDS AND CONNECTORS Inspect the engine s interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector interferes with engine operation Contact NCR Support for information about cable replacement ...

Страница 200: ... displayed on the host device correctly but a key still needs to be pressed to enter it for example the Enter or Return key or the Tab key A suffix needs to be programmed Programming a suffix enables the engine to output the bar code data plus the key needed such as CR to enter the data into the application Note Refer to Prefix Suffix Overview section of Chapter 4 for further information Does the ...

Страница 201: ...code is readable 3 Verify that your bar code symbology is enabled Refer to the Symbologies chapter of this book 4 If the engine still can t read the sample bar codes scan All Symbologies bar code Refer to the All Symbologies section of Chapter 6 If you are not sure what programming option are set in the engine or if you want the factory default settings restored scan the Activate Defaults bar code...

Страница 202: ...Maintenance 9 4 B005 0000 2166 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions ...

Страница 203: ...e Sensible Code Han Xin Code X0 H 0x48 Codabar Fm 0 1 a 0x61 Codablock A O6 0 1 4 5 6 V 0x56 Codablock F Om 0 1 4 5 6 q 0x71 Code 11 H3 h 0x68 Code 128 Cm 0 1 2 4 j 0x6A GS1 128 C1 I 0x49 Code 32 Pharmaceutical PARAF X0 0x3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 0x62 Code 49 Tm 0 1 2 4 l 0x6C Code 93 and 93i Gm 0 9 A Z a m i 0x69 Data Matrix dm 0 6 w 0x77 EAN 13 including Bookland EAN ...

Страница 204: ...s Post X0 K 0x4B Korea Post X0 0x3F Matrix 2 of 5 X0 m 0x6D MaxiCode Um 0 3 x 0x7 8 MicroPDF417 Lm 3 5 R 0x52 MSI Mm 0 g 0x67 NEC 2 of 5 X0 Y 0x59 OCR MICR E 13 B o3 O 0x4F OCR SEMI Font o3 O 0x4F OCR A o1 O 0x4F OCR B o2 O 0x4F PDF417 Lm 0 2 r 0x72 Planet Code X0 L 0x4C Postal 4i X0 N 0x4E Postnet X0 P 0x50 QR Code and Micro QR Code Qm 0 6 s 0x73 Straight 2 of 5 IATA Rm 0 1 3 f 0x66 Straight 2 of...

Страница 205: ...8 12 DEVICE CONTROL 2 DC2 3 3 END OF TEXT ETX 19 13 DEVICE CONTROL 3 DC3 4 4 END OF TRANSMISSION EOT 20 14 DEVICE CONTROL 4 DC4 5 5 END OF QUERY ENQ 21 15 NEGATIVE ACKNOWLEDGEMENT NAK 6 6 ACKNOWLEDGE ACK 22 16 SYNCHRONIZE SYN 7 7 BEEP BEL 23 17 END OF TRANSMISSION BLOCK ETB 8 8 BACKSPACE BS 24 18 CANCEL CAN 9 9 HORIZONTAL TAB HT 25 19 END OF MEDIUM EM 10 A LINE FEED LF 26 1A SUBSTITUTE SUB 11 B VE...

Страница 206: ...7 g 40 28 72 48 H 104 68 h 41 29 73 49 I 105 69 i 42 2A 74 4A J 106 6A j 43 2B 75 4B K 107 6B k 44 2C 76 4C L 108 6C l 45 2D 77 4D M 109 6D m 46 2E 78 4E N 110 6E n 47 2F 79 4F O 111 6F o 48 30 0 80 50 P 112 70 p 49 31 1 81 51 Q 113 71 q 50 32 2 82 52 R 114 72 r 51 33 3 83 53 S 115 73 s 52 34 4 84 54 T 116 74 t 53 35 5 85 55 U 117 75 u 54 36 6 86 56 V 118 76 v 55 37 7 87 57 W 119 77 w 56 38 8 88 5...

Страница 207: ... 140 8C Œ 183 B7 226 E2 â 141 8D 184 B8 227 E3 ã 142 8E Ž 185 B9 228 E4 ä 143 8F 186 BA º 229 E5 å 144 90 187 BB 230 E6 æ 145 91 188 BC 231 E7 ç 146 92 189 BD 232 E8 è 147 93 190 BE 233 E9 é 148 94 191 BF 234 EA ê 149 95 192 C0 À 235 EB ë 150 96 193 C1 Á 236 EC ì 151 97 194 C2  237 ED í 152 98 195 C3 à 238 EE î 153 99 196 C4 Ä 239 EF ï 154 9A š 197 C5 Å 240 F0 ð 155 9B 198 C6 Æ 241 F1 ñ 156 9C œ ...

Страница 208: ... ISO 2022 Automatic National Replacement Characters 3 CP Binary 51 ISO 8859 1 51 Western European Replacement Characters 82 ISO 2022 11 Swe Swedish Replacement Characters 83 ISO 2022 69 Fra French Belgium Replacement Characters 81 ISO 2022 25 Fra French Belgium Replacement Characters 84 ISO 2022 11 Ger German Replacement Characters 85 ISO 2022 11 Ita Italian Replacement Characters 86 ISO 2022 11 S...

Страница 209: ...166 11 1 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions Table of Contents Chapter 11 Samples and Programming Chart SAMPLE SYMBOLS UPC A Interleaved 2 of 5 Code 128 Ean 13 0 123456 7890 1234567890 Code 128 9 780330 290951 ...

Страница 210: ...ing Chart 11 2 B005 0000 2166 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions Code 39 CodaBar Code 93 Straight 2 of 5 Industrial Matrix 2 of 5 GS1 DataBar BC321 A13579B 123456 9 123456 6543210 123456 ...

Страница 211: ...ONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions PDF 417 Postnet Data Matrix QR Code 4 CB 4 State Customer Bar Code ID Tag UPU 4 State Car Registration Zip Code Test Symbol Numbers 01 234 567894 987654321 01234567891 J18CUSA856N062315014880T ...

Страница 212: ...Samples and Programming Chart 11 4 B005 0000 2166 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions Aztec MicroPDF 417 Maxi Code Package Label Test Messenger Test Message ...

Страница 213: ...Samples and Programming Chart B005 0000 2166 11 5 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions PROGRAMMING CHART 0 1 2 3 4 5 6 7 ...

Страница 214: ...Samples and Programming Chart 11 6 B005 0000 2166 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions 8 9 A B C D E F Save ...

Страница 215: ...PRIETARY Use pursuant to Company Instructions If an error is made while scanning the letters or digits before the Save bar code is scanned perform the following steps 1 Scan the Discard bar code above 2 Scan the correct letters or digits 3 Scan the Save bar code Discard Reset ...

Страница 216: ...Samples and Programming Chart 11 8 B005 0000 2166 NCR CONFIDENTIAL AND PROPRIETARY Use pursuant to Company Instructions ...

Отзывы: