DC (Analog) MODE
Press ENTER to turn DC operation mode off, press 1 to turn DC mode on. We
recommend leaving DC mode off for most layouts. This is to prevent all your
locomotives from taking off at once in case of a failure in your power station or
someone accidentally connecting the track to a DC power supply (it happens
more often than you might think).
DC MODE 02:00PM
DC MODE 02:00PM
DC MODE 02:00PM
DC MODE 02:00PM
DC MODE 02:00PM
ENTER=NO 1=YES_
ENTER=NO 1=YES_
ENTER=NO 1=YES_
ENTER=NO 1=YES_
ENTER=NO 1=YES_
ADVANCED ACKNOWLEDGE
Press ENTER to turn Advanced Acknowledge mode off, press 1 to turn Advanced
Acknowledge mode on.
ADV ACK? 02:00PM
ADV ACK? 02:00PM
ADV ACK? 02:00PM
ADV ACK? 02:00PM
ADV ACK? 02:00PM
ENTER=NO 1=YES _
ENTER=NO 1=YES _
ENTER=NO 1=YES _
ENTER=NO 1=YES _
ENTER=NO 1=YES _
NOTE: advanced acknowledgment is not operational in any decoders at this time
as the NMRA has not defined how it is to work.
SPEED TABLE SELECTION
If the Standard Speed Table is to be used, press ENTER. If the Alternate
(uploadable) Speed Table in the decoder is to be used, press 1.
SPEEDTBL 02:00PM
SPEEDTBL 02:00PM
SPEEDTBL 02:00PM
SPEEDTBL 02:00PM
SPEEDTBL 02:00PM
ENTER=STD 1=ALT_
ENTER=STD 1=ALT_
ENTER=STD 1=ALT_
ENTER=STD 1=ALT_
ENTER=STD 1=ALT_
ENABLE LONG OR SHORT ADDRESS
The short address is used when operating on DCC systems that do not use long
addresses.
ADDRESS 02:00PM
ADDRESS 02:00PM
ADDRESS 02:00PM
ADDRESS 02:00PM
ADDRESS 02:00PM
ENTER=S 1=LONG:_
ENTER=S 1=LONG:_
ENTER=S 1=LONG:_
ENTER=S 1=LONG:_
ENTER=S 1=LONG:_
SET MOTOR CONTROL PARAMETERS (Option 4)
This option can be used to setup the various locomotive motor speed control
parameters. You can skip adjusting any of these parameters (CVs) by pressing
ENTER without entering The first adjustment is:
START VOLTAGE (CV2)
Start voltage is the amount of voltage the decoder sends to the motor when a
speed step 1 command is sent to the locomotive. This is some extra voltage to
help get the motor running. You can put in any value from 0-255. If you put in a
value of 10 then 10/255 (about 4%) of the full motor voltage will be applied to the
motor at speed step 1.
OPS PROG 11:22AM
OPS PROG 11:22AM
OPS PROG 11:22AM
OPS PROG 11:22AM
OPS PROG 11:22AM
START VOLTS: _
START VOLTS: _
START VOLTS: _
START VOLTS: _
START VOLTS: _
In most decoders the start voltage is added to each speed step. A good way to
setup the Start Voltage is to first set your throttle to speed 1 then go into this Start
Voltage programming and try different values until you get the desired starting
speed. This approach can be used with most of the motor speed adjustments. You
may exit programming at any time by pressing PROG/ESC.