Environmental Specifications 

Certain components of a PM controller may run at temperatures exceeding 120

°

 

Degrees Fahrenheit.  This is normal for a PM controller and does not indicate a defect. 

The recommended operating temperature for all PM controllers is -25 to +85

°

 C.  This 

temperature rating is based on temperature specifications of the components used to 

build a PM controller and is not based on actual testing.  We have speculated that PM 
controllers may be able to withstand lower temperatures due to the fact that PM 

controllers tend to have hot components in critical areas of the design. 

Break-Away Tabs 

Physically, most MirC controllers are actually 2 sizes.  When you receive your 
MirC, the unusual shape and size ensures the MirC can fit into a standard 

enclosure.  Optionally, you can make the controller smaller by breaking away the 
out tabs.  Break Away tabs are useful in applications where space may be a 

concern.  This allows your MirC to offer the same functionality in the smallest 
possible profile.  Break Away tabs are unique to the NCD product line and are a 

standard option for most devices released in 2010 and later. 

Before breaking the tabs on your controller, please be advised that your MirC 
controller will not be returnable for refund or credit if the Break Away Tabs have 

been removed. 

To break away the tabs, gently but firmly grab each break-away tab with a pair of 

pliers and bend the tab back and forth until it breads away from the main circuit 
board.  This will NOT damage the controller in any way. 

Breaking the Tabs from a controller DOES NOT VOID the warranty.  Please see 

the 

NCD return policy if you would like more information on the policies that 

apply to Surface Mount devices. 

 

 

 

Содержание PR60-12 MIRCC8 WIFI

Страница 1: ...NATIONAL CONTROL DEVICES Push Notification WiFi Quick Start Guide...

Страница 2: ...V I C E S Push Notification WiFi Quick Start Guide National Control Devices LLC PO Box 455 Osceola MO 64776 Phone 417 646 5644 Fax 866 562 0406 Copyright 2013 All Rights Reserved Notice Portions of th...

Страница 3: ...Getting Started 2 WiFi Module Configuration 2 WiFi Network Setup 2 TCP Notification Setup 4 UDP Notification Setup 4 Initial Testing 5 Hardware Reference 6 Compatible Sensors Understanding Inputs 6 P...

Страница 4: ...Advanced Configuration 10 Input Configuration 10 User Definable Transmitted Bytes 11 Troubleshooting 12 Technical Support 13 Contact Information 14 Notice 14...

Страница 5: ...5 managers Android devices informing them a customer has entered the building A notification could be sent to a small local server such as the WiNet which can in turn send an email notification when t...

Страница 6: ...ation Software Things you will need Push Notification series controller with included WiFi module WiFi configuration kit Zigmo configuration board and USB cable A windows based computer XP 7 or 8 WiFi...

Страница 7: ...cting to the module and reading its input s status if needed We recommend that you leave the Join Network On Power Up box checked this means as soon as the module powers up it will associate with the...

Страница 8: ...d between Base Station and the WiFi module in the Log window At the end you should see Associated and then farther down a line that says IP the address next to this line will be the IP address of your...

Страница 9: ...ter later Click the Chain icon button in the upper left corner of Com operator to open a new connection If you set the module up for UDP broadcast click the UDP tab enter the port number specified as...

Страница 10: ...pecifications PM controllers require a 12VAC or 12VDC power supply to power the logic and relays of the controller The PWR12 is our stock power supply suitable for use with ALL PM Series controllers W...

Страница 11: ...standard enclosure Optionally you can make the controller smaller by breaking away the out tabs Break Away tabs are useful in applications where space may be a concern This allows your MirC to offer t...

Страница 12: ...00 would indicate v1 0 Bytes 4 9 indicate the WiFi module s Mac address Convert these bytes to Hexadecimal bytes for Mac format Bytes 10 17 are user definable This can be used for any purpose require...

Страница 13: ...tripped its value will be 0 When the input is tripped it will be pulled high and its status will be 255 It is recommended that you assume any input above 200 is tripped with a contact Reads the 8 Bit...

Страница 14: ...to the controller and display a window with control software options Select AD8 Relay Activator Event Generator Step 3 The AD8 Relay Activator Event Generator window will now be displayed You will not...

Страница 15: ...module in the IP address text field Enter the Port defined as the TCP Listener port I the WiFi module by default this is set to 2101 Then click the OK button below Step 2 Base Station will communicate...

Страница 16: ...r is not received on server computer Fix Make sure you do not have any type of antivirus software which could block TCP UDP sockets McAfee is known for this Windows firewall can also sometimes block t...

Страница 17: ...iott our technical engineer If you feel that you have discovered a bug in the firmware of our controllers contact Ryan Sheldon our hardware developer If you have programming related questions or have...

Страница 18: ...ct Information National Control Devices LLC PO Box 455 Osceola MO 64776 417 646 5644 phone 866 562 0406 fax Open 9 a m 4 p m CST All orders must be placed online at our website www controlanything com...

Отзывы: