background image

18

NBB Co  

Components  

GmbH

Accessories

Charger for charging NiMH rechargeable batteries (7.2 V)

 

Display of the charging procedure via a DUO-LED:

 

LED – continuously lights up green:   STANDBY. Charger is ready for operation.  

Insert the battery in the battery compartment.

 

LED – continuously lights up orange:   CHARGING. The battery is being charged.

 

LED – rapidly flashing orange: 

Charging complete.

 

LED – slowly flashing orange:  

 Battery is deeply discharged or ambient temperature  
for quick charging is too low. There is a regeneration or  
warm-up phase with reduced charging current before  
changing over to actual quick charging.

 
 

 Leaving the battery in the charger beyond the charging time is not a hazard.  
Only use the charger when it is dry!

 

Detection and evaluation of the following start states:

 

 Undervoltage: 

Pre-charging with reduced charging current 

Insufficient temperature:  Pre-charging with reduced charging current (warm up) 
Excessive voltage: 

No start of charging procedure 

  
Shutdown when permitted maximum temperature is reached.

Universal charger

2.250.1449 

Basic Universal-Charger (12 V/24 V DC)
without connecting cable for 7.2 V battery,  
black

    

2.250.1450

Universal-Charger (2.250.1449) (12 V/24 V DC)
for PNN battery 7.2 V, power supply Glob Tek Inc. (3.970.1448) 
with euro plug (3.970.1449), 2 m cabel (100/240 V AC / 12 V)

2.251.1450

Universal-Charger (2.250.1449) (12 V/24 V DC)
for PNN battery 7.2 V, power supply Glob Tek Inc. (3.970.1448) 
with 4 Adapter plug (3.970.1451), 2 m cabel (100/240 V AC / 12 V)

2.250.1452

Battery charger (12 V/24 V/DC)
for PNN battery 7.2 V, black, 2 m cabel connected  
with cigarette lighter plug (3.970.1451)

2.250.1453

Universal-Charger (2.250.1449) (12 V/24 V DC)
for battery 7.2 V, with charger Glob Tek (3.970.1455) + 4 plugs (3.970.1456)  
and cigarette lighter plug (3.970.1451) (100/240 V AC / 12 V)

Содержание Compact-V 9600 Baud

Страница 1: ...onents GmbH Flexibly designed complete solutions Radio Control Systems Cable Control Systems Infrared Control Systems Operating instructions Radio Control System MS Compact V 9600 Baud Transmitter Tra...

Страница 2: ...NBB Controls Components GmbH 2...

Страница 3: ...Contents 3 General information 4 Transmitter Nano L SMJ 7 2V 6 Receiver Compact V 9600 Baud 12 Accessories 16 Technical documents 20...

Страница 4: ...NBB radio control system must be shut down immediately in case of failures The transmitter must be switched off using the EMERGENCY STOP switch or STOP button The connection cable at the receiver must...

Страница 5: ...at the expense of the buyer Worn parts relays rechargeable batteries and batteries are excluded from the warranty The functional warranty does not cover damage accidental damage negligence improper u...

Страница 6: ...ter Nano L SMJ 7 2V Variations Nano L SMJ 7 2 V with 3 Joysticks Nano L SMJ 7 2 V with Display and 4 Joysticks Nano L SMJ 7 2 V with Display and 2 Joysticks Nano L SMJ 7 2 V with 2 Joysticks Nano L SM...

Страница 7: ...rvice life Safety equipment Safety equipment in the NBB radio control system EMERGENCY STOP or STOP function Zero position interlock Addressing each transmitter using a unique Binary bit code combinat...

Страница 8: ...position If necessary release the emergency stop pushbutton by turning clockwise To ensure faultless free operation please observe the following rules The system to be controlled provided the transmit...

Страница 9: ...time bring the unit into a safe position switch off the transmitter and replace the batteries with charged batteries Energy saving function If no buttons are pressed within a specified time the transm...

Страница 10: ...Surface Mounted Joystick see below Surface Mounted Joystick teach mode activation with pushbutton To activate teach mode the transmitter must be switched off 1 Press and hold the Frequency switching k...

Страница 11: ...ttons to enter and store min and max values for valves could differ from the description above In this case a separate supplemental information sheet will be attached to the operating instructions Tec...

Страница 12: ...12 NBB Controls Components GmbH Receiver Compact V 9600 Baud Variations Compact VC Compact VB Compact VD Compact VE Edition 12 15...

Страница 13: ...tronics cannot be supplied Please make sure that the operating voltage of the receiver corresponds with the connection plans of the system to be controlled The valid operating voltage is noted in the...

Страница 14: ...OP switch or STOP button at the transmitter until the switch engages Then observe if the unit to be controlled is switched off time to switch off according to the application Meaning of the LED displa...

Страница 15: ...on 16 million options Safety EMERGENCY STOP with self test Restart lockout in the event of a faulty EMERGENCY STOP relay Contact load of EMERGENCY STOP relay Max 4A 250V AC Contact load of relay Max 6...

Страница 16: ...16 NBB Controls Components GmbH Accessories Battery 7 2V and charger for 7 2V battery NiMH battery 7 2V Charger for charging NiMH rechargeable batteries 7 2 V Edition 11 15...

Страница 17: ...r subject it to strong impact Protect the battery from rain moisture and extreme temperatures Keep the contacts clean and make sure the battery does not come into contact with metal objects e g alumin...

Страница 18: ...tates Undervoltage Pre charging with reduced charging current Insufficient temperature Pre charging with reduced charging current warm up Excessive voltage No start of charging procedure Shutdown when...

Страница 19: ...integrated charger Quick charging approx 1h R16 R CAN Compact M Compact V Normal charging approx 3h PNN BUS 3 Technical data Power supply 9V 32V DC e g by 12V 24V on board electrical system Note the...

Страница 20: ...20 NBB Controls Components GmbH...

Страница 21: ...21 Technical documents...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ...GN 12 V DC X1 3 Power Supply 0 V AC 9 F2 4A T IN_X6 2 Common 2 K11 Emergency stop OUT_X6 1 EMERGENCY STOP 3 K1 K1A B OUT _X6 3 Hoist UP DOWN 4 2 2 4 4 POT1 IN _X7 1 Common 5 K2 K1A B OUT_X7 2 Hoist U...

Страница 27: ...mmon 29 K4 1 OUT_X10 K4 1 SW13 OUT_X11 Compressor OFF 30 IN_POT 5 Common 31 K5 1 OUT_X12 K5 1 SW09 OUT_X13 Spare ON on off 32 IN_POT 13 Common 33 K13 1 OUT_X17 K13 1 SW11 OUT_X18 Spare ON on off 34 IN...

Страница 28: ...v1_4_v2_12 txt 7 segment display 1 FREQUENCY BAND 1 3 300 1605 FACEPLATE 2 korean frequency Charger 2s FM yes Auto Off no Active Passive LBT Mode 1 S_9600120085_v1_0 scd switch adapter board black bla...

Страница 29: ...V013 E SW19A6 V1 3 BOARD 2 1 2 100 1270_V015 S AD06A0 V1 5 BOARD 1 1 2 100 1382_V013 E SW10A1 V1 3 silver printed FACEPLATE 1 3 820 1195 black LOWER PART 1 3 300 1503 PROGRAM 2 UPPER PART 1 2 250 1500...

Страница 30: ......

Страница 31: ......

Страница 32: ...ls Components GmbH Otto Hahn Stra e 3 5 75248 lbronn D rrn GERMANY Fon 49 7237 999 0 Fax 49 7237 999 199 sales nbb de www nbbcontrols de Edition 05 18 We reserve the right to alter specifications with...

Отзывы: