Getting Started with MAXserver Access Servers
0038
34
The following screen displays:
Xyplex>> MONITOR PARAMETER SERVER
MX1620 V6.0.4S18 Rom 470000 HW 00.00.00 Lat Protocol V5.2 Uptime: 13 18:11:56
Address: 88-00-87-23-33-6B Name: X03346B Number: 0
21 Dec 1998 10:24:45
Check Timer: 30 Parameter Server Limit: 4
Retransmit Timer: 5 Parameter Servers: 4
Retransmit Limit: 3 Rejected Servers: 39
Bad Parameter Messages: 0
Path:
Last Update Version: 102C5 Storage State: Idle
Last Update Date: 07 Dec 1998 Loaded From: 08-00-87-03-34-6B
Last Update Time: 16:12:53 X03346B
Name Address Version Date Status Reason
Local MemCard 88-00-87-23-33-6B 102C5 07 Dec 1998 16:12 Current
Local NVS 88-00-87-23-33-6B 102C5 07 Dec 1998 16:12 Current
Figure 9 - Monitor Parameter Server Display
The storage process is completed when the “Status” column on this display
says “Current” for all parameter servers, and the “Storage State” field says
“Idle.” When these conditions are met, you can turn the unit off.You can
reset the MAXserver to force it to run a self test or to re-initialize the unit.
Before resetting the server, check the port lights to make sure that no
connections are in progress. All connections are terminated when the server
is reset.
To reset the MAXserver, follow these steps:
1.
Make a simple "tool" from an ordinary paper clip by bending one end
outward. You need this tool to press the RESET button located behind
the MAXserver front panel.
2.
Look for the small hole between the CONSOLE light and the light
labeled '1’ (see Figure 10).