Note: 

It is recommended to connect one of the universal input (usually 

UIN1

) to the vehicle 

ignition line

 and make the 

appropriate setting in the configuration. However, such connection is not mandatory.  

In addition to the source of notifications about turning on and turning off events, the input is used in coordinate 

processing algorithms (for example, when they are averaged at parking lots), energy saving, when calculating engine hours 

and in some other device algorithms. 

Any input which configured for operation with a discrete sensor can be used as an ignition. 

 

14

7

13

6

12

5

11

4

10

3

9

8

2

1

Fuse

(1А)

+U

Ignition

switch

UIN1

Alarm

button

«GND»

«GND»

«+»

«-»

Car battery

 

 

Figure 26. Connection of the ignition lock and alarm button

 

 

Digital inputs are configured in the “Input lines” tab of the NTC Configurator program. 

 

 

2.4.3 Pulse frequency sensors connection 

 

Сonnecting  frequency  or  pulse  sensors,  it  is  necessary  to  consider  how  the  output  signal  is  generated  in  these 

sensors. Further setting of the input depends on this.  

It is necessary to set the threshold level of fixation correctly, in order the device correctly determine the frequency 

or calculate the pulses.  

Connecting pulse or frequency sensors, the output of which is implemented according to the “open collector” (OC) 

circuit with pull-up resistor, it is not necessary to turn on the Pull-UP circuit in the device by the setting.  

 

CPU_adc 

R

1

R

2

UIN

C

1

Q2

R

p

R

pu

CPU_pull-up

VDD

+U

 

 

Figure 27. Connection of sensors with an “OC” type output circuit with a pull-up resistor in the sensor 

 

When pulse flow meters with a reed sensor is connected, one contact of which is connected to the “ground”, it is 

necessary to include an internal pull-up resistor in the device setup. 

Содержание SMART S-2423

Страница 1: ...GPS GLONASS TRACKING EQUIPMENT SMART S 2423 Operations manual Installation and connection of the device v1 0 MOSCOW 2020...

Страница 2: ...terested in constantly improvement of the manufactured products quality Please contact our technical support by email address support navtelecom ru should you have any questions or problems with the d...

Страница 3: ...terface connector 11 2 DEVICE CONNECTION 12 2 1 Installation 12 2 2 SIM card installation and operation 13 2 3 Power connection 13 2 4 Universal inputs connection 14 2 4 1 Analog sensors connection 14...

Страница 4: ...senger s safety 1 3 Operational principles The device during its operation continuously monitors the status of the connected sensors vehicle battery voltage built in device battery voltage GSM modem s...

Страница 5: ...2 V voltage in operation mode on Average2 mA 80 Current consumption at 12 V voltage with turned off GLONASS and GSM modules is no more than mA 20 Maximum current consumption at 12 V voltage in the ope...

Страница 6: ...operating voltage is exceeded the power protection is activated The device continues to work but is powered by the battery 2 If GPRS operates in poor communications peak consumption 10 ms consumption...

Страница 7: ...iniUSB connector for connection with a computer SIM card holder slot with ejector yellow button In the upper part of the device unit figure3 there are three indicators system indicator SYS modem opera...

Страница 8: ...terface cable with MiniUSB connector 1 5 Passport 1 6 Package 1 Figure 4 14 pin connector of Microfit 14 Figure 5 Interface cable with MiniUSB connector Some cases may require connection of additional...

Страница 9: ...External LED Figure 9 Temperature sensor Figure 10 TouchMemory contact key reader The manufacturer reserves the right to complete the devices with equipment whose set appearance and characteristics di...

Страница 10: ...es 11 14 1 front cover 2 fixing hole 3 system LED indicator 4 GSM LED indicator 5 GLONASS GPS LED indicator 6 14 pin connector 7 MiniUSB connector 8 SIM card 1 ejector holder 9 SIM card holder 1 exter...

Страница 11: ...Figure 13 Figure 14...

Страница 12: ...ltage from 0 V to 31 V FLS impulse fuel consumption sensors DRL buttons or switches Attention It is prohibited to apply a voltage more than 50 V to the device universal inputs because it may lead to t...

Страница 13: ...perature more than 60 C for example near heating systems etc It is also prohibited to place the device in a sealed container without heat dissipation It is prohibited to install tracker in places with...

Страница 14: ...the power supply through a 1 A fuse not included in standard equipment set During installation the power supply should be connected the last turn when all the other equipment is already connected Conn...

Страница 15: ...The device allows to connect any type of sensors that have two steady states on activated and off normal The voltage thresholds at which the device fixes the sensor on activating or off switching to n...

Страница 16: ...ice via the UIN1 will differ from the scheme used to connect to the UIN2 and UIN3 Rpu CPU_adc R1 R2 UIN C1 CPU_pull up VDD Figure 20 Connection of normally open NO sensors to UIN2 UIN3 CPU_adc R1 R2 U...

Страница 17: ...crete NC and Discrete NO allow to work with sensors which when turned on or off close the input to supply voltage CPU_adc R1 R2 UIN C1 U Rpu CPU_pull up VDD Figure 24 Connection of normally open NO se...

Страница 18: ...the Input lines tab of the NTC Configurator program 2 4 3 Pulse frequency sensors connection onnecting frequency or pulse sensors it is necessary to consider how the output signal is generated in thes...

Страница 19: ...ccelerometer three axis acceleration sensor soft and strong impact sensors displacement sensor and tilt sensor in the device They can be used for alerts as well as external lines Accelerometer is also...

Страница 20: ...lt in generator can be connected to any output Connection diagrams for buzzer with build in generator and for buzzer without build in generator have no difference 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse...

Страница 21: ...ll connections must be made through the fuse Figure 33 Designation of the external relay contacts When voltage is applied to control contacts relay is activated and closes or opens the electrical circ...

Страница 22: ...te with DS1990 keys or key card readers that emulate DS1990 keys via interface 1 Wire Each DS1990 key is a chip with a unique identification number stitched into it at the manufacturing plant by which...

Страница 23: ...d of the bus that is opposite to the connected device it should be closed by the last plug in sensor 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse 1A GND Car battery Temperature sensors DS1820 Data Data Data...

Страница 24: ...uld be connected to the RS 485 line of the sensor usually designated as B The RS 485 interface specifications practically do not limit the length of cables on a land vehicle 100m or more since the int...

Страница 25: ...cond off There is a registration in the cellular network of the operator Weak signal 2 short flashes 1 second off There is a registration in the cellular network of the operator Medium quality signal...

Отзывы: