1-Wire interface 

yes 

Number  of  outputs  of  the  “open  collector”  type  for  the  external  devices 

control 

Maximum switching current by the control outputs, mA 

 

500 

Maximum switching voltage by the control outputs, V 

48 

Built-in 3-axis accelerometer 

yes 

Maximum impact loading measured by the device, g 

Performance specifications 

Enclosure protection level 

IP54 

Maximum allowable overload during impacts, g 

24 

Storage temperature with the battery

5

 ,

o

0 … +40 

Storage temperature without the battery, 

o

-40 … +85 

Operating temperature with the battery, 

o

-20 … +60 

Operating temperature without the battery, 

o

-40 … +85 

Temperature at which the battery is possible to charge, 

o

0 … +50 

Maximum allowable humidity level at 35 

o

C, % 

95 

Device dimensions with connectors, mm 

102х57х22 

Device weight, kg 

0,086 

 

1.

 

If maximum operating voltage is exceeded the power protection is activated. The device continues to work, but is 

powered by the battery.  

2.

 

If GPRS operates in poor communications, peak consumption (10 ms), consumption of the device can accede 500 mA. 

3.

 

Attention!

 

Lithium  polymer  battery  (Li-Po)  is  used  in  the  device.  The  following  rules  must  be  observed  during  its 

operation: not to heat, keep away from sources of heat, not to throw the battery into the fire, not to expose to direct 

sunlight. The device, for power of which Li-Po battery is used, cannot be used in high humidity, high and low ambient 

temperatures. Operation is permitted under the conditions specified by the manufacturer. Not to hit, not to deform, 

not to disassemble, not to close contacts.  

4.

 

Protection against battery charge while it is overcooled or overheated.  

5.

 

When the device is stored and used outside the specified temperatures, it is recommended to turn it off and remove 

the battery from the device to avoid damage to the battery and to the device. 

 

 

 

 

Содержание SMART S-2423

Страница 1: ...GPS GLONASS TRACKING EQUIPMENT SMART S 2423 Operations manual Installation and connection of the device v1 0 MOSCOW 2020...

Страница 2: ...terested in constantly improvement of the manufactured products quality Please contact our technical support by email address support navtelecom ru should you have any questions or problems with the d...

Страница 3: ...terface connector 11 2 DEVICE CONNECTION 12 2 1 Installation 12 2 2 SIM card installation and operation 13 2 3 Power connection 13 2 4 Universal inputs connection 14 2 4 1 Analog sensors connection 14...

Страница 4: ...senger s safety 1 3 Operational principles The device during its operation continuously monitors the status of the connected sensors vehicle battery voltage built in device battery voltage GSM modem s...

Страница 5: ...2 V voltage in operation mode on Average2 mA 80 Current consumption at 12 V voltage with turned off GLONASS and GSM modules is no more than mA 20 Maximum current consumption at 12 V voltage in the ope...

Страница 6: ...operating voltage is exceeded the power protection is activated The device continues to work but is powered by the battery 2 If GPRS operates in poor communications peak consumption 10 ms consumption...

Страница 7: ...iniUSB connector for connection with a computer SIM card holder slot with ejector yellow button In the upper part of the device unit figure3 there are three indicators system indicator SYS modem opera...

Страница 8: ...terface cable with MiniUSB connector 1 5 Passport 1 6 Package 1 Figure 4 14 pin connector of Microfit 14 Figure 5 Interface cable with MiniUSB connector Some cases may require connection of additional...

Страница 9: ...External LED Figure 9 Temperature sensor Figure 10 TouchMemory contact key reader The manufacturer reserves the right to complete the devices with equipment whose set appearance and characteristics di...

Страница 10: ...es 11 14 1 front cover 2 fixing hole 3 system LED indicator 4 GSM LED indicator 5 GLONASS GPS LED indicator 6 14 pin connector 7 MiniUSB connector 8 SIM card 1 ejector holder 9 SIM card holder 1 exter...

Страница 11: ...Figure 13 Figure 14...

Страница 12: ...ltage from 0 V to 31 V FLS impulse fuel consumption sensors DRL buttons or switches Attention It is prohibited to apply a voltage more than 50 V to the device universal inputs because it may lead to t...

Страница 13: ...perature more than 60 C for example near heating systems etc It is also prohibited to place the device in a sealed container without heat dissipation It is prohibited to install tracker in places with...

Страница 14: ...the power supply through a 1 A fuse not included in standard equipment set During installation the power supply should be connected the last turn when all the other equipment is already connected Conn...

Страница 15: ...The device allows to connect any type of sensors that have two steady states on activated and off normal The voltage thresholds at which the device fixes the sensor on activating or off switching to n...

Страница 16: ...ice via the UIN1 will differ from the scheme used to connect to the UIN2 and UIN3 Rpu CPU_adc R1 R2 UIN C1 CPU_pull up VDD Figure 20 Connection of normally open NO sensors to UIN2 UIN3 CPU_adc R1 R2 U...

Страница 17: ...crete NC and Discrete NO allow to work with sensors which when turned on or off close the input to supply voltage CPU_adc R1 R2 UIN C1 U Rpu CPU_pull up VDD Figure 24 Connection of normally open NO se...

Страница 18: ...the Input lines tab of the NTC Configurator program 2 4 3 Pulse frequency sensors connection onnecting frequency or pulse sensors it is necessary to consider how the output signal is generated in thes...

Страница 19: ...ccelerometer three axis acceleration sensor soft and strong impact sensors displacement sensor and tilt sensor in the device They can be used for alerts as well as external lines Accelerometer is also...

Страница 20: ...lt in generator can be connected to any output Connection diagrams for buzzer with build in generator and for buzzer without build in generator have no difference 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse...

Страница 21: ...ll connections must be made through the fuse Figure 33 Designation of the external relay contacts When voltage is applied to control contacts relay is activated and closes or opens the electrical circ...

Страница 22: ...te with DS1990 keys or key card readers that emulate DS1990 keys via interface 1 Wire Each DS1990 key is a chip with a unique identification number stitched into it at the manufacturing plant by which...

Страница 23: ...d of the bus that is opposite to the connected device it should be closed by the last plug in sensor 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse 1A GND Car battery Temperature sensors DS1820 Data Data Data...

Страница 24: ...uld be connected to the RS 485 line of the sensor usually designated as B The RS 485 interface specifications practically do not limit the length of cables on a land vehicle 100m or more since the int...

Страница 25: ...cond off There is a registration in the cellular network of the operator Weak signal 2 short flashes 1 second off There is a registration in the cellular network of the operator Medium quality signal...

Отзывы: