background image

 

 

1.8 Device interface connector 

14

7

13

6

12

5

11

4

10

3

9

8

2

1

NC

RS

485

A

(+

)

RS

485

B

(-

)

iB

U

T

NC

NC

O

U

T

2

O

U

T

1

U

IN

3

U

IN

2

U

IN

1

G

N

D

+

Ug

NC

 

Figure 15. System 14-pin interface connector 

 

1 - Power “Plus” (+ U

G

2 – “Ground” (GND) 
3 - Universal input 1 (UIN1) 

4 - Universal input 2 (UIN2) 

5 - Universal input 3 (UIN3) 

6 – Output 1 "open collector" (OUT1) 

7 – Output 2 "open collector" (OUT2) 

8 – Not used 
9 – Not used 

10 - 1-Wire Interface Line (iBUT) 

11 - RS-485 interface line (RS-485B (-)) 

12 - RS-485 interface line (RS-485A (+)) 

13 – Not used 

14 – Not used 

 

“Plus” of the main power U

should be connected via an external fuse. 

 

«Ground» GND

 is connected to the "ground" of the car. 

 

The universal inputs UIN1, UIN2 и UIN3

 can be set up as discrete, analog, counting or frequency. It allows to 

connect to them a wide range of different sensors, for example, frequency (frequency from 1 Hz to 2000 Hz) and analog 

(voltage from 0 V to 31 V) FLS, impulse fuel consumption sensors (DRL), buttons or switches. 

 

Attention! 

It is prohibited to apply a voltage more than 50 V to the device universal inputs, because it may lead to the failure 

of the device. 

 

Outputs OUT1 and OUT2

 «open collector» type are designed to control low-current loads up to 500 mA. When 

activated, a negative signal ("Ground")  is formed on these  lines. Connection of external  executive devices with a  load 

current higher than the maximum allowed should be made using additional switching relays. The relay type is selected 

based on the requirements for the value of the switched current, voltage, and also depending on the power of the connected 
device. 

 

The interface line 

1-Wire (iBUT)

 is used to connect the contact pads of TouchMemory keys, Proximity-card readers 

and digital heat-sensing device. 

 

The digital interface RS-485

 is designed for connection of various devices transmitting and receiving information 

on this interface, for example, fuel level sensors (up to 6 pcs.), CAN bus adapter, RFID. 

 

 

 

Содержание SMART S-2423

Страница 1: ...GPS GLONASS TRACKING EQUIPMENT SMART S 2423 Operations manual Installation and connection of the device v1 0 MOSCOW 2020...

Страница 2: ...terested in constantly improvement of the manufactured products quality Please contact our technical support by email address support navtelecom ru should you have any questions or problems with the d...

Страница 3: ...terface connector 11 2 DEVICE CONNECTION 12 2 1 Installation 12 2 2 SIM card installation and operation 13 2 3 Power connection 13 2 4 Universal inputs connection 14 2 4 1 Analog sensors connection 14...

Страница 4: ...senger s safety 1 3 Operational principles The device during its operation continuously monitors the status of the connected sensors vehicle battery voltage built in device battery voltage GSM modem s...

Страница 5: ...2 V voltage in operation mode on Average2 mA 80 Current consumption at 12 V voltage with turned off GLONASS and GSM modules is no more than mA 20 Maximum current consumption at 12 V voltage in the ope...

Страница 6: ...operating voltage is exceeded the power protection is activated The device continues to work but is powered by the battery 2 If GPRS operates in poor communications peak consumption 10 ms consumption...

Страница 7: ...iniUSB connector for connection with a computer SIM card holder slot with ejector yellow button In the upper part of the device unit figure3 there are three indicators system indicator SYS modem opera...

Страница 8: ...terface cable with MiniUSB connector 1 5 Passport 1 6 Package 1 Figure 4 14 pin connector of Microfit 14 Figure 5 Interface cable with MiniUSB connector Some cases may require connection of additional...

Страница 9: ...External LED Figure 9 Temperature sensor Figure 10 TouchMemory contact key reader The manufacturer reserves the right to complete the devices with equipment whose set appearance and characteristics di...

Страница 10: ...es 11 14 1 front cover 2 fixing hole 3 system LED indicator 4 GSM LED indicator 5 GLONASS GPS LED indicator 6 14 pin connector 7 MiniUSB connector 8 SIM card 1 ejector holder 9 SIM card holder 1 exter...

Страница 11: ...Figure 13 Figure 14...

Страница 12: ...ltage from 0 V to 31 V FLS impulse fuel consumption sensors DRL buttons or switches Attention It is prohibited to apply a voltage more than 50 V to the device universal inputs because it may lead to t...

Страница 13: ...perature more than 60 C for example near heating systems etc It is also prohibited to place the device in a sealed container without heat dissipation It is prohibited to install tracker in places with...

Страница 14: ...the power supply through a 1 A fuse not included in standard equipment set During installation the power supply should be connected the last turn when all the other equipment is already connected Conn...

Страница 15: ...The device allows to connect any type of sensors that have two steady states on activated and off normal The voltage thresholds at which the device fixes the sensor on activating or off switching to n...

Страница 16: ...ice via the UIN1 will differ from the scheme used to connect to the UIN2 and UIN3 Rpu CPU_adc R1 R2 UIN C1 CPU_pull up VDD Figure 20 Connection of normally open NO sensors to UIN2 UIN3 CPU_adc R1 R2 U...

Страница 17: ...crete NC and Discrete NO allow to work with sensors which when turned on or off close the input to supply voltage CPU_adc R1 R2 UIN C1 U Rpu CPU_pull up VDD Figure 24 Connection of normally open NO se...

Страница 18: ...the Input lines tab of the NTC Configurator program 2 4 3 Pulse frequency sensors connection onnecting frequency or pulse sensors it is necessary to consider how the output signal is generated in thes...

Страница 19: ...ccelerometer three axis acceleration sensor soft and strong impact sensors displacement sensor and tilt sensor in the device They can be used for alerts as well as external lines Accelerometer is also...

Страница 20: ...lt in generator can be connected to any output Connection diagrams for buzzer with build in generator and for buzzer without build in generator have no difference 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse...

Страница 21: ...ll connections must be made through the fuse Figure 33 Designation of the external relay contacts When voltage is applied to control contacts relay is activated and closes or opens the electrical circ...

Страница 22: ...te with DS1990 keys or key card readers that emulate DS1990 keys via interface 1 Wire Each DS1990 key is a chip with a unique identification number stitched into it at the manufacturing plant by which...

Страница 23: ...d of the bus that is opposite to the connected device it should be closed by the last plug in sensor 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse 1A GND Car battery Temperature sensors DS1820 Data Data Data...

Страница 24: ...uld be connected to the RS 485 line of the sensor usually designated as B The RS 485 interface specifications practically do not limit the length of cables on a land vehicle 100m or more since the int...

Страница 25: ...cond off There is a registration in the cellular network of the operator Weak signal 2 short flashes 1 second off There is a registration in the cellular network of the operator Medium quality signal...

Отзывы: