1

Calibrating the Magnetic Resistance Sensor  

on the Schwinn

 IC4 / IC8 

and Bowflex

 

C6 Bikes

Skill Level: I

8025408.011520.A

Replacement Procedure

NOTICE:  

This document provides instructions to calibrate the Magnetic Resistance Sensor on the Schwinn

 IC4 / IC8 and Bowflex

 C6 Bikes. This procedure may be useful if:

    -the Resistance Knob can be rotated, and the Level value on the Console never changes from 0%. 

    -the Resistance Knob can be fully rotated counter-clockwise, and the Level value never reaches 0%.

    -the Resistance Knob is fully rotated clockwise, and the Level value never reaches 100%.

Note: 

Be sure to confirm that all cable connections are secure before performing the calibration. Due to product limitations, the Magnetic Resistance Sensor can only be cali

-

brated three times.

If you need assistance, please call 

Nautilus

 Customer Service (if purchased in US/Canada) or your local distributor (if purchased out-

side US/Canada). To find your local distributor, go to: www.nautilusinternational.com

This icon means a potentially hazardous situation which, if not avoided, could result in death or serious injury. Read and understand 

all Warnings on this machine.

Important Safety Instructions - Before servicing or using this equipment, obey the following warnings:

This icon means a potentially hazardous situation which, if not avoided, could result in death or serious injury. Read and understand 

all Warnings on this machine.

• Read and understand the Part Replacement Procedure before working on the machine. Failure to obey the instructions and safety warnings could cause 

injury to the service technician or bystanders. 

• Keep bystanders and children away from the product being serviced at all times. 

• 

Disconnect all power to the machine before you service it.

• Make sure that the repair is done in an appropriate work space away from foot traffic and exposure to bystanders.

 

• Some components of the equipment can be heavy or awkward. Enlist the service of a second person when you do maintenance steps involving these 

components. Do not try to do heavy or awkward steps on your own. 

• 

Use only replacement parts and hardware that are supplied or approved by Nautilus. Failure to use Nautilus-approved replacement parts can adversely 

affect the safety and functionality of the equipment creating a risk to users and will void the warranty.

• 

Be sure that all warning stickers and instructional placards applied to the product stay present and in good condition when doing maintenance or 

replacing components.  If at any time the Warning labels become loose, unreadable or dislodged, replace the labels. If purchased in US/Canada, contact 

Customer Service for replacement labels. If purchased outside US/Canada, contact your local distributor for them.

• Do not try to change the design or functionality of the machine being serviced as this can adversely affect user safety. 

• Do not use the machine until all shrouds, instructions, warning labels and correct functionality have been verified and tested for correct performance.