![Nautilus Hyosung MX5300CE Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/nautilus-hyosung/mx5300ce/mx5300ce_service-manual_3515387031.webp)
Chapter3. User Handling Unit Service Manual
3-10
© 2012
Nautilus Hyosung, Inc.
All Rights Reserved.
Troubleshooting Procedure
▶
The screen is blank.
1. “No signal” message is displayed on the LCD.
-> Check whether the DVI cable is properly connected to OPL Assy or VGA card.
-> Check if the main board is in hang-up state or powered off.
-> Check if the display setting of the VGA card is active (using SPL.)
* If the system was booted with the video cable (DVI or RGB) being disconnected,
reconnecting the cable may not solve the problem.
Tip) CTRL+ALT+F1: Activates DVI display.
▶
The LCD is black.
1. Backlight of the LCD panel is off.
-> Check the power cable connection status of OPL assembly. (Check +24V input.)
-> Check the LED color of the OSD board.
- LED OFF: The AD board is in off state. Press OSD Power On/Off button.
- Green ON: The AD board is in normal state.
*Check or replace the inverter cable or inverter board.
-> If the trouble persists, replace the AD board.
-> If the trouble persists even after the AD board is replaced, replace the LCD
assembly.
2. Backlight of the LCD panel is on.
-> Connect/Disconnect the power line of OPL assembly.
-> If “Nautilus HYOSUNG” logo is not displayed on the OPL screen, replace the AD
board.
▶
The LCD is displayed white.
▶
The LCD is displayed white.
-> Check the installation status of the LVDS cable inside the assembly.
-> If the trouble persists even when the installation status is normal, replace the cable.
-> If the trouble persists even after the cable is replaced, replace the AD board.
-> IF the trouble persists even after the AD board is replaced, replace OPL assy.
▶
When the screen is in red or other colors (when the color display is normal)
-> Check the connection status of the video cable. (Connect again.)
-> Check whether the video cable has not been damaged using spare video cable.
-> Check the connection status of the LVDS cable. (Connect again.)
-> If the trouble persists, replace the LVDS cable.
-> If the trouble persists even after LVDS cable is replaced, replace the AD board.
▶
The screen does not provide visible display.
-> Replace the LVDS cable.
-> If the trouble persists, replace the AD board.
Содержание MX5300CE
Страница 1: ...Service Manual MX5300CE System V01 00 03 2013 05 30 Nautilus Hyosung Inc All Rights Reserved...
Страница 59: ...Chapter4 Control Electronics Service Manual 4 8 Nautilus Hyosung Inc All Rights Reserved...
Страница 84: ...Chapter6 Safe Unit Service Manual 6 6 Nautilus Hyosung Inc All Rights Reserved Changing Batteries...
Страница 85: ...Service Manual Chapter6 Safe Unit Nautilus Hyosung Inc All Rights Reserved 6 7 Changing Batteries Option...