LOW FREQUENCY 

 
Pure Sine Wave 
Inverter 

 

USER MANUAL 

 
 
 

MODEL: PM-0350L 

PM-0650L 

PM-1000L 

PM-1200L 

PM-1800L 

PM-3000L 

 

Содержание PM-0350L

Страница 1: ...ew Main Functions G Pre Installation Information H Electrical Requirements I Installation Requirements J Connection And Testing K Operation L Green Power Adjustment M Trouble shooting N Maintenance O Specifications LOW FREQUENCY Pure Sine Wave Inverter USER MANUAL MODEL PM 0350L PM 0650L PM 1000L PM 1200L PM 1800L PM 3000L ...

Страница 2: ...ssor based design with accurate and stable frequency Compact light weight rugged and vehicle rated 83 90 efficient Standard outputs adjustable 100 120V 200 240V 50 60Hz Standard specially designed AC and DC line filters Panel indicators for battery voltage load level Does not affect other equipment like TV radio etc Standard inputs 12V 24V 48V Custom design Aluminum chassis for harsh environments ...

Страница 3: ...ne powered machinery fuel tanks or joints fittings or other connections between components of the fuel system 3 Precautions When Working With Batteries If battery acid contacts skin or clothing wash immediately with soap and water If acid gets into eyes immediately flood eyes with running cold water for at least 20 minutes and get medical attention immediately z NEVER smoke or allow a spark or fla...

Страница 4: ...tlet Outlet sockets available North America GFCI North America Continental European Schuko Australia New Zealand United Kingdom Universal Socket A Rear view main functions 1 Ventilation window Do not obstruct allow at least 1 inch for airflow 2 Battery terminals Connect to 12V 24V 48V battery or other 12V 24V 48V power source is positive is negative WARNING Reverse polarity connection will blow in...

Страница 5: ...ere flammable fumes may exist such as fuel storage or engine compartments Ventilation Allow at least one inch of clearance around the inverter for airflow Ensure the ventilation openings on the rear and bottom of the unit are not obstructed The installation site should not be susceptible to temperatures in excess of 50 C Dust free Do not install the inverter in an environment where either dust woo...

Страница 6: ... inverter from its shipping container and inspect the unit for any obvious transit damage Report any concerns immediately to your supplier Mount the inverter to a suitable surface paying close attention to the mounting requirements previously mentioned in this manual 2 AC Wiring Important to satisfy warranty requirements and conditions a qualified electrician must perform all AC wiring 3 DC Wiring...

Страница 7: ...e with the electrical codes or regulations applicable to your installation Cables that are not an adequate gauge too narrow or are too long will cause decreased inverter performance such as poor surge capability frequent low input voltage warnings and shutdowns J Connection and Testing For a quick connection and performance check please follow these guidelines 1 Unpack and inspect the power invert...

Страница 8: ...s normal Plug the test load into the AC receptacle on the front panel of the inverter Leave the test load switch off 7 Set power inverter switch to the ON position and turn the test load on The inverter should supply power to the load If you plan to measure the output voltage of the inverter a meter such as FLUKE 45 BECKMAN or other Digital Volt meter must be used WARNING You may observe a spark w...

Страница 9: ...e power inverter has shut down because it has become overheated The power inverter may overheat because it has been operated at power levels above its rating or because it has been installed in a location which does not allow it to dissipate heat properly The power inverter will restart automatically once it has cooled off 5 Overload indicator The overload indicator indicates that the power invert...

Страница 10: ...verter by turning the Standby control slightly counter clockwise until the lamp shows steady green Increase the amount of AC load on the inverter Inverter shuts down due to Over Temperature Your inverter will safely provide the output power defined in the technical data section under the conditions specified If the inverter shuts down and indicates over temperature it may be that you have exceeded...

Страница 11: ...ymptoms Possible Cause Solution Low output voltage Using average reading Use true RMS 110V 95 105VAC Voltmeter and cable 220V 190 210VAC See page 7 Point 6 7 of manual Load LED flashes Overload Reduce load Remove Load Under Volt LED flash Low input voltage Recharge battery check connections and cable OVER TEMP flash Thermal shutdown Improve ventilation N Maintenance Very little maintenance is requ...

Страница 12: ...tions 0150 WATT 0350 WATT 0650 WATT 1000 WATT 1200 WATT 1800 WATT 3000 WATT DC TO AC INVERTER INPUT 12 VDC 24 VDC 48 VDC OUTPUT 1 110 V 2 220 V TYPE A N American B U K C Australia D Europe E Universal PM 0150L 12 1 E ...