background image

 

 

Содержание 17906

Страница 1: ...1...

Страница 2: ...em through the innovative designs of our products We strive to achieve a high level of user friendliness by allowing stress free installation and easy operation of all important functions of the camer...

Страница 3: ...ntents 6 Precautions 7 Specifications 9 Identification of Parts 10 Opening and Locking the Housing 12 Preparation of the Housing 14 Installing the Monitor 20 Connecting to the Camera Housing 22 Care a...

Страница 4: ...om the day that the product is shipped from our facility This warranty only applies to products purchased from authorised NAUTICAM dealers and does not extend beyond the original retail purchaser To r...

Страница 5: ...h and or placed within our products NAUTICAM accepts no liability for any loss of captured images or the inability to capture images even if it is due to the malfunctioning of our products Unauthorise...

Страница 6: ...emover CR2032 battery Lubricant Set of Allen keys Instruction manual For 17906 NA 502H 1 HDMI A D cable in 750mm length pre installed 2 M16 HDMI bulkhead 3 HDMI D C cable in 130mm length 4 HDMI D C ca...

Страница 7: ...nt provided by NAUTICAM Discontinue use immediately should you notice any leakage Store the housing in a robust shock proof container during transportation avoid transporting with any equipment such a...

Страница 8: ...e the product in an environment of high humidity Do not leave the housing and the monitor in direct sunlight for prolonged periods Keep out of reach of children failure to do so could result in injury...

Страница 9: ...struction Housing body Aluminium alloy Surface treatment Hard anodised Display window Abrasion resistant polycarbonate Dimensions Width 222mm Height 118mm Depth 67mm Weight Approx 1 39kg Buoyancy Dept...

Страница 10: ...tion button M22 accessory port Moisture alarm window Monitor on off button Center button Left selection button Right selection button Down selection button Back button M16 vacuum valve Capture button...

Страница 11: ...11 Housing lock safety button Ball mount Sacrificial zinc anode M16 accessory port Housing lock HDMI cable SDI cable Cable cap...

Страница 12: ...12 OPENING AND LOCKING THE HOUSING To open the housing 1 Press the housing lock safety button 2 Turn the housing lock anti clockwise for 270 until the lock reaches the Open position as shown...

Страница 13: ...lose the housing while the housing lock is in the Open position 4 Turn the housing lock clockwise for 270 until the lock reaches the lock position as shown Confirm that the white indicator line on the...

Страница 14: ...in the front part of the housing is free from any foreign material the groove can be cleaned with the aid of a microfiber cloth 3 Place the main O ring into the groove first at the corners then the w...

Страница 15: ...es into flashing blue light standby mode 3 Test the alarm by connecting the two wires near the bottom of the housing with a damp cotton bud the alarm should start giving out a repeating beep sound alo...

Страница 16: ...eady green light Attention After the target vacuum is reached i e steady green light attach the cap back to the vacuum valve 4 It is recommended to leave the housing for at least 20mins to ensure it i...

Страница 17: ...of the camera and lens Attention Although the vacuum indicator is designed to compensate for a certain amount of temperature variation it is recommended to conduct the vacuum test in an environment wh...

Страница 18: ...cates a 2nd generation PCB Steady Blue light Battery is normal goes into flashing Blue light standby mode after 5 seconds Blue and Red lights alternating Battery low Replace battery as soon as possibl...

Страница 19: ...eeping sound Moisture is detected Flashing Yellow light Some vacuum is detected target vacuum level is not reached Steady Green light Target vacuum level is reached Rapidly flash Yellow light Vacuum i...

Страница 20: ...stall the monitor into to the housing 1 Turn the two locking levers in the direction as shown 2 Connect the HDMI cable with L connector to the monitor s HDMI in socket as shown above or HD SDI cable t...

Страница 21: ...21 3 Place the monitor inside the housing and secure the monitor by turning the two locking levers towards the monitor as shown...

Страница 22: ...CTING TO THE CAMERA HOUSING For installing the standard HDMI bulkhead with M16 thread or M16 SDI bulkhead 3 Unscrew the M16 plug from the threaded hole with a coin 2 Tighten the HDMI or HD SDI bulkhea...

Страница 23: ...23 3 Connect the HDMI HD SDI cable to the HDMI HD SDI bulkhead 4 Connect the HDMI HD SDI cable to the camera s HDMI HD SDI socket...

Страница 24: ...24 For installing the custom HDMI bulkhead to use with extension 1 Unscrew the M16 plug from the accessory port with a coin 2 Tighten the socket extension to the camera housing with a spanner...

Страница 25: ...25 3 Insert the HDMI cable through the threaded hole from inside of the housing 4 Connect the HDMI cable to the HDMI bulkhead...

Страница 26: ...26 5 Tighten the HDMI bulkhead by turning the threaded ring on the socket extension 6 Connect the HDMI cable to the camera s HDMI connector...

Страница 27: ...27 To connect the monitor housing to HDMI SDI bulkhead 1 Unscrew the cap off the HDMI SDI bulkhead 2 Unscrew the cap off the HDMI HD SDI cable...

Страница 28: ...28 3 Align and plug the HDMI HD SDI cable in the HDMI HD SDI bulkhead Tighten the connection by turning the threaded ring on the HDMI HD SDI cable...

Страница 29: ...deo signal to be sent topside to a director s monitor Note Extra HD SDI bulkhead 25058 and cables 25060 for internal connection 25064 15m HD SDI Surface Feed Cable or 25065 45m HD SDI Surface Feed Cab...

Страница 30: ...30 2 Tighten the HD SDI bulkhead with a spanner 3 Connect the HD SDI cable to the HD SDI bulkhead and to the monitor SDI out socket...

Страница 31: ...31 4 Remove the cap of both HD SDI bulkhead and HD SDI Surface Feed Cable then plug the cable to the bulkhead 5 Tighten the connection by turning the threaded ring on the HD SDI cable...

Страница 32: ...oved from its groove with the O ring remover and inspected for damage Also check that the O ring retains its original circular shape never stretch the O ring excessively or remove it with a sharp obje...

Страница 33: ...I bulkhead P N 25060 SDI cable in 0 4m length P N 25063 SDI cable in 30m length for connection between SDI Bulkheads P N 25064 25065 SDI surface monitor cable in 15m 45m length for connection from SDI...

Страница 34: ...34...

Отзывы: