XR6/XR3 Troubleshooting Manual
Detailed Circuit Descriptions
Page 2-24
Issue 3.0 2009-07-15
U7A's output will switch to a current-sink-to-ground. A ground potential will be applied to the
junction of DS3/CR35 through CR34. The 15 V current source will be removed from J3-11. The PA
input/output PWB's RF amplifier fault detector circuit will be reset if it was activated. Its fault
detection capability will be inhibited as long as the junction of DS3/CR35 is a ground potential (see
“RF amplifier failure detector” on page 2-27
Modulator short circuit detector
There are four identical modulator short circuit detectors, one for each power block. Since they are all
identical, only the circuit for power block A is described.
Comparator U10A and its associated components form the modulator short circuit detector. A
+15 V reference voltage is applied to U10A's non-inverting input. The
PA Volts (A)
input (J1-5) is a
dc voltage that is representative of the PDM1 signal. A portion of the
PA Volts (A)
input is applied to
U10A's inverting input by dual voltage divider R51/R56/R57.
During normal operation, the PA voltage sample applied to U10A's inverting input will be less
positive than the reference voltage applied to its non-inverting input. U10A's output will be open
collector.
When a modulator malfunction occurs, which results in the PA voltage being the same as the B+
voltage (i.e., a shorted FET in the modulator), the PA voltage sample applied to U10A's inverting
input will be more positive than the reference voltage applied to its non-inverting input. U10A's
output will switch to a current-sink-to-ground, causing the
MOD SHORT
LED (DS9) to turn on.
Reset pulse generator
Transistor Q1 and inverter U3A are connected as a one shot pulse generator. When a momentary
ground potential is applied to J4-10 as a logic true
Reset PM
command, Q1 will turn on. 5 V will be
applied to the input of U3A and cause its output to switch to a current-sink-to-ground while Q1 is
on. This current-sink-to-ground will:
•
Remove the 24 V pull-up voltage from the junction of R16/R17 and effectively clamp U3C's
input to ground potential. U3C's output will be clamped to its open collector state for the
reset pulse period. If U2B was latched in its high temp fault state, U3C's open collector state
will unlatch U2B and reset the high temp detector.
•
Remove the 24 V pull-up voltage from the junction of R16/R15 and effectively clamp U2D's
output to ground potential for the reset pulse period. If U2D was latched in its low RF drive
fault state, the removal of the 24 V pull-up voltage will unlatch it. The latching low RF drive
detector will be reset.
Содержание XR6
Страница 2: ......
Страница 4: ......
Страница 8: ...XR6 XR3 Troubleshooting Manual Table of contents Page viii Issue 3 0 2009 07 15...
Страница 12: ...XR6 XR3 Troubleshooting Manual Page xii Issue 3 0 2009 07 15...
Страница 20: ...XR6 XR3 Troubleshooting Manual Page xx Issue 3 0 2009 07 15...
Страница 68: ...XR6 XR3 Troubleshooting Manual Responding to alarms Page 1 48 Issue 3 0 2009 07 15...
Страница 212: ...XR6 XR3 Troubleshooting Manual Wiring connector lists Page 4 18 Issue 3 0 2009 07 15...
Страница 218: ...XR6 XR3 Troubleshooting Manual Reading Electrical Schematics Page 5 6 Issue 3 0 2009 07 15...
Страница 228: ...Issue 3 1 2014 05 07 SD 9 Figure SD 9 NAPX05E 02 Dynamic Carrier Control PWB Sheet 1of 2...
Страница 229: ...Issue 3 1 2014 05 07 SD 10 Figure SD 10 NAPX05E 02 Dynamic Carrier Control PWB Sheet 2 of 2...
Страница 238: ...Issue 3 1 2014 05 07 SD 19 Figure SD 19 NAP34A RF Power Module Overall Sheet 1 of 2...
Страница 239: ...Issue 3 1 2014 05 07 SD 20 Figure SD 20 NAP34A RF Power Module Modulator Stage Sheet 2 of 2...
Страница 240: ...Issue 3 1 2014 05 07 SD 21 Figure SD 21 NAPC150A RF Drive Control PWB Sheet 1 of 3...
Страница 241: ...Issue 3 1 2014 05 07 SD 22 Figure SD 22 NAPC150A RF Drive Control PWB Sheet 2 of 3...
Страница 242: ...Issue 3 1 2014 05 07 SD 23 Figure SD 23 NAPC150A RF Drive Control PWB Sheet 3 of 3...
Страница 243: ...Issue 3 1 2014 05 07 SD 24 Figure SD 24 NASM07H Modulator Assembly...
Страница 244: ...Issue 3 1 2014 05 07 SD 25 Figure SD 25 NAA51A 03 RF Amplifier Assembly...
Страница 247: ...Issue 3 1 2014 05 07 SD 28 Figure SD 28 Not Used...
Страница 251: ...Issue 3 1 2014 05 07 SD 31 Figure SD 31 NAPS10B RF Drive Power Supply PWB...
Страница 254: ...Issue 3 0 2009 07 15 MD 1A Figure MD 1A XR6 XR3 Transmitter 3 Phase Ac...
Страница 255: ...Issue 3 0 2009 07 15 MD 1B Figure MD 1B XR6 XR3 Transmitter 1 Phase Ac...
Страница 256: ...Issue 3 0 2009 07 15 MD 2 Figure MD 2 NAC115A Control Panel Rear View A1 Control Display PWB A2 DCC PWB optional...
Страница 258: ...Issue 3 0 2009 07 15 MD 4 Figure MD 4 NAPX05E 02 Dynamic Carrier Control PWB optional NAPX05E 01 shown NAPX05E 02...
Страница 264: ...Issue 3 0 2009 07 15 MD 10 Figure MD 10 NAPP02 02 RF Current Probe PWB...
Страница 266: ...Issue 3 0 2009 07 15 MD 12 Figure MD 12 NAFP103 05 Forward Reflected Power Probe A1 DETAIL...
Страница 270: ...Issue 3 0 2009 07 15 MD 16 Figure MD 16 NAPC150A RF Drive Control PWB...
Страница 272: ...Issue 3 0 2009 07 15 MD 18 Figure MD 18 NASM07H Modulator Assembly...
Страница 273: ...Issue 3 0 2009 07 15 MD 19 Figure MD 19 PA Input Output PWB 176 1065 04 and 05...
Страница 274: ...Issue 3 0 2009 07 15 MD 20 Figure MD 20 NAA51A 03 RF Amplifier Assembly...
Страница 275: ...Issue 3 0 2009 07 15 MD 21 Figure MD 21 NAPI47B Modulator Input Output PWB...
Страница 278: ...Issue 3 0 2009 07 15 MD 24 Figure MD 24 Relay Assy 202 7019 01...
Страница 279: ...Issue 3 0 2009 07 15 MD 25 Figure MD 25 Fan Tray 202 7020 J1 B1 B2...
Страница 280: ...Issue 3 0 2009 07 15 MD 26 Figure MD 26 NAPS10C RF Drive Power Supply 62 V...
Страница 283: ...Issue 3 0 2009 07 15 MD 28A Figure MD 28A Rectifier Assembly 3 Phase Ac 202 7017...
Страница 284: ...Issue 3 0 2009 07 15 MD 28B Figure MD 28B Rectifier Assembly 1 Phase Ac 202 7220...
Страница 290: ......