XR6/XR3 Pre-installation Manual
Cooling requirements
Issue 3.0 2009-07-15
Page 4-3
Calculating BTU cooling requirements
To determine the number of British thermal units (Btu) being generated per hour as waste heat,
multiply the average RF output power (in watts) by 0.19 (the heat factor at rated power) and then
multiply the product by 3.413.
Closed loop or forced air cooling systems
Closed loop or forced air cooling systems can be used, so long as the air is well filtered to prevent
dust and insects from entering the transmitter, and so long as a minimum of 200 cubic feet per
minute (CFM) at 0.5 pounds per square inch (PSI) is supplied to the intake duct.
Heating
The transmitter room must contain a heating system that will ensure the ambient air temperature
does not drop below 0°C (32°F).
Содержание XR6
Страница 2: ...blank...
Страница 4: ...blank...
Страница 8: ...XR6 XR3 Pre installation Manual Page viii Issue 3 0 2009 07 15...
Страница 12: ...XR6 XR3 Pre installation Manual Page xii Issue 3 0 2009 07 15...
Страница 20: ...XR6 XR3 Pre installation Manual Page xx Issue 3 0 2009 07 15...
Страница 24: ...XR6 XR3 Pre installation Manual Description Page 1 4 Issue 3 0 2009 07 15...
Страница 28: ...XR6 XR3 Pre installation Manual Pre installation tasks Page 2 4 Issue 3 0 2009 07 15...
Страница 34: ...XR6 XR3 Pre installation Manual Physical requirements Page 3 6 Issue 3 0 2009 07 15...
Страница 38: ...XR6 XR3 Pre installation Manual Cooling requirements Page 4 4 Issue 3 0 2009 07 15...
Страница 56: ...XR6 XR3 Pre installation Manual Control and monitoring Page 6 14 Issue 3 0 2009 07 15...
Страница 62: ...XR6 XR3 Pre installation Manual RF output requirements Page 8 4 Issue 3 0 2009 07 15...
Страница 66: ...XR6 XR3 Pre installation Manual Parts and tools Page 9 4 Issue 3 0 2009 07 15...
Страница 88: ...XR6 XR3 Pre installation Manual Page IX 6 Issue 3 0 2009 07 15...
Страница 89: ......