RESPONDING TO ALARMS
VX150 TO VX2 TROUBLESHOOTING MANUAL
PAGE 3.1.26
VERSION 2.0 2023-04-20
No Exciter Comms
The System Interface PWB is not receiving
valid communication packets from the Exciter.
The System Interface PWB receives a valid
communication packet from the Exciter.
This alarm is most likely caused by
temporary comms interruptions during
software upgrades or Exciter reboots. If
the alarm is occurring outside of those
cases check the connection between the
Exciter and System Interface Board.
No Nameplate License
The License.json file loaded from the SD card
at boot is corrupted or missing.
When present, this alarm may limit the output
power of the transmitter. If the Transmitter
model is a VX1 it’s likely you will observe PA2
failures.
This alarm requires an AC cycle or Exciter
reboot to clear.
To remain cleared, the system must boot with
a valid license file.
The most likely cause of this alarm is
installation of a new generic SD card
after replacement. By default, the SD
does not contain any license file as this
file is unique to each transmitter. It is
also possible that the license file has
become unreadable due to corruption.
Contact Nautel customer support for your
transmitter’s license key and instructions
on how to re-load the key.
On Audio Backup
This alarm will trigger when the Transmitter
switches to operating on a backup audio
source as configured in the active preset.
This alarm will clear immediately when the
main audio source returns.
Performing an alarm reset will clear this
alarm.
This alarm should always be present with
a low audio alarm. It serves as an
additional indicator that a switch to the
backup audio source has occurred.
PA 1 Bias Fail
The Autobias routine was unable to reach the
150mA target bias current for PA 1 within the
timeout of 3 minutes or within the allowable
minimum and maximum bias voltages.
This alarm is cleared by starting the Autobias
routine.
Performing an alarm reset will clear this
alarm.
Check PA 1 connections, fuse, and FET.
The most likely cause of this alarm is a
bad connection or failed PA.
Attempt to re-run the Autobias routine.
Check the System Interface Board (See
SD-9) TP5 & TP6 voltage matches the PA
(1) Bias meter when RF is ON and
operating.
Consider replacing PA 1. See
Amplifier PWB Replacement on
page 3.1.60
.
Alarm Name
Trigger Conditions
Clear Conditions
Troubleshooting
Содержание VX150
Страница 2: ......
Страница 4: ......
Страница 8: ...VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE VIII VERSION 2 0 2023 04 20...
Страница 42: ...RESPONDING TO ALARMS VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE 3 1 34 VERSION 2 0 2023 04 20...
Страница 132: ......
Страница 136: ...VX150 TO VX2 TROUBLESHOOTING MANUAL WIRING INFORMATION PAGE 3 3 4 VERSION 2 0 2023 04 20...
Страница 142: ...VX150 TO VX2 TROUBLESHOOTING MANUAL ELECTRICAL SCHEMATICS PAGE 3 4 6 VERSION 2 0 2023 04 20...
Страница 168: ...VERSION 2 0 2023 04 20 MD 6 Figure MD 6 NAPI189 Analog Audio PWB...
Страница 169: ...VERSION 2 0 2023 04 20 MD 7 Figure MD 7 NAPI187A System Interface PWB...
Страница 170: ...VERSION 2 0 2023 04 20 MD 8 Figure MD 8 NAPI188 01 Power Supply Interface PWB VX150 VX300 VX600...
Страница 171: ...VERSION 2 0 2023 04 20 MD 9 Figure MD 9 NAPI188 Power Supply Interface PWB VX1 VX1 5 VX2...
Страница 172: ...VERSION 2 0 2023 04 20 MD 10 Figure MD 10 NAPI193 Front Panel User Interface PWB...
Страница 173: ...VERSION 2 0 2023 04 20 MD 11 Figure MD 11 NAPA41 Pre Amp IPA PWB...
Страница 174: ...VERSION 2 0 2023 04 20 MD 12 Figure MD 12 NAPA40A Power Amplifier PWB...
Страница 175: ...VERSION 2 0 2023 04 20 MD 13 Figure MD 13 NAPF16A Low Pass Filter PWB...
Страница 176: ...VERSION 2 0 2023 04 20 MD 14 Figure MD 14 NAPP15A Directional Coupler Bottom PWB...
Страница 177: ...VERSION 2 0 2023 04 20 MD 15 Figure MD 15 NAPH15 2 Way Splitter PWB VX1 5 VX2...
Страница 178: ...VERSION 2 0 2023 04 20 MD 16 Figure MD 16 2 Way Combiner PWB Nautel Part PU03B VX1 5 VX2...
Страница 180: ...VX LP TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 3 6 2 VERSION 2 0 2023 04 20...
Страница 181: ......