VX150 TO VX2 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
VERSION 2.0 2023-04-20
PAGE 3.1.23
Low Ac Foldback
The AC Voltage meter is less than 185 VAC
and the output power setpoint in the active
preset is greater than 750W.
The presence of this alarm will cause a
reduction in output power to 750W.
This alarm is only present in VX1.5 and VX2
models.
The AC voltage meter is greater than 185
VAC.
This alarm will also clear if RF is OFF or if the
output power setpoint in the active preset is
reduced to below 750W.
The most likely cause for this alarm is a
phase failure or brownout on the AC
supply to the transmitter.
Check the AC supply voltage at the
transmitter connection.
If the Transmitter has been intentionally
connected to a 120 VAC supply, then
reduce the setpoint below 750W.
Low Ac Shutback
The AC Voltage meter is less than 90 VAC.
The presence of this alarm will temporarily
inhibit RF operation until cleared.
This alarm will automatically clear when the
AC Voltage meter is greater than 90 VAC.
The most likely cause for this alarm is a
brownout or other failure on the AC
supply to the transmitter.
Check the AC supply voltage at the
transmitter connection.
Low Ambient Temperature
Warning
The Ambient Temperature meter is less than
0
°
C.
No action is taken on this alarm.
This alarm will automatically clear when the
Ambient Temperature meter is greater than
5
°
C.
Check site heating or ventilation system.
Allow transmitter to warm above 0
°
C
before operating.
Low Forward Power
The Forward Power meter measures a value
less than the Low Forward Power Threshold
(User-Adjustable, default: 50% of the active
preset output power setpoint) for at least 1
second.
No action is taken on this alarm.
This alarm will automatically clear when the
Forward Power meter value is greater than
the Low Forward Power Threshold for at least
1 second.
Check for other transmitter alarms, this
alarm serves as a general indicator
resulting from any substantial reduction
of Transmitter Forward Power.
Low RF Drive
The RF Drive meter measures a value less than
the minimum expected drive level for the
given transmitter model when RF is ON and
uninhibited.
The RF Drive meter measures a value greater
than the minimum expected drive level for
the given transmitter model.
This alarm will automatically clear if RF is
turned OFF or RF is otherwise inhibited.
The most likely cause of this alarm is
either an IPA failure, an Exciter failure,
or a disconnection in-between.
Check the IPA connections, fuse, and
FET.
Check the signal level out of the Exciter
J10 using a spectrum analyzer or other RF
measurement device.
Alarm Name
Trigger Conditions
Clear Conditions
Troubleshooting
Содержание VX150
Страница 2: ......
Страница 4: ......
Страница 8: ...VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE VIII VERSION 2 0 2023 04 20...
Страница 42: ...RESPONDING TO ALARMS VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE 3 1 34 VERSION 2 0 2023 04 20...
Страница 132: ......
Страница 136: ...VX150 TO VX2 TROUBLESHOOTING MANUAL WIRING INFORMATION PAGE 3 3 4 VERSION 2 0 2023 04 20...
Страница 142: ...VX150 TO VX2 TROUBLESHOOTING MANUAL ELECTRICAL SCHEMATICS PAGE 3 4 6 VERSION 2 0 2023 04 20...
Страница 168: ...VERSION 2 0 2023 04 20 MD 6 Figure MD 6 NAPI189 Analog Audio PWB...
Страница 169: ...VERSION 2 0 2023 04 20 MD 7 Figure MD 7 NAPI187A System Interface PWB...
Страница 170: ...VERSION 2 0 2023 04 20 MD 8 Figure MD 8 NAPI188 01 Power Supply Interface PWB VX150 VX300 VX600...
Страница 171: ...VERSION 2 0 2023 04 20 MD 9 Figure MD 9 NAPI188 Power Supply Interface PWB VX1 VX1 5 VX2...
Страница 172: ...VERSION 2 0 2023 04 20 MD 10 Figure MD 10 NAPI193 Front Panel User Interface PWB...
Страница 173: ...VERSION 2 0 2023 04 20 MD 11 Figure MD 11 NAPA41 Pre Amp IPA PWB...
Страница 174: ...VERSION 2 0 2023 04 20 MD 12 Figure MD 12 NAPA40A Power Amplifier PWB...
Страница 175: ...VERSION 2 0 2023 04 20 MD 13 Figure MD 13 NAPF16A Low Pass Filter PWB...
Страница 176: ...VERSION 2 0 2023 04 20 MD 14 Figure MD 14 NAPP15A Directional Coupler Bottom PWB...
Страница 177: ...VERSION 2 0 2023 04 20 MD 15 Figure MD 15 NAPH15 2 Way Splitter PWB VX1 5 VX2...
Страница 178: ...VERSION 2 0 2023 04 20 MD 16 Figure MD 16 2 Way Combiner PWB Nautel Part PU03B VX1 5 VX2...
Страница 180: ...VX LP TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 3 6 2 VERSION 2 0 2023 04 20...
Страница 181: ......