background image

 
 
NxLink 

ETHERNET INTERFACE MODULE 
 
 
Technical Instruction Manual 

 

 

 
Issue 2.0 .......... 23 August 2022 
 
 

Nautel Limited 

10089 Peggy's Cove Road, 
Hackett's Cove, NS, Canada B3Z 3J4 
T.877 6 nautel (628835) or +1.902.823.2233 
F.+1.902.823.3183 [email protected] 

 

U.S. customers please contact: 

Nautel Inc. 

201 Target Industrial Circle, Bangor ME 04401 
T.877 6 nautel (628835) or +1.207.947.8200 
F.+1.207.947.3693  [email protected] 
 
e-mail: [email protected] 

www.nautel.com 

 

 Copyright 2022 NAUTEL. All

 

rights reserved. 

Содержание NxLink

Страница 1: ...Cove NS Canada B3Z 3J4 T 877 6 nautel 628835 or 1 902 823 2233 F 1 902 823 3183 info nautel com U S customers please contact Nautel Inc 201 Target Industrial Circle Bangor ME 04401 T 877 6 nautel 6288...

Страница 2: ......

Страница 3: ...the buyers expense If the old module is not received after 30 days the customer will be invoiced The buyer is responsible for installing the replacement repaired module in the transmitter 5 In the ev...

Страница 4: ...arranty shall be between the Buyer and the third party provider 13 Nautel provides telephone and email support for its products for the life of the product at no charge After the warranty period parts...

Страница 5: ...itter experiences a failure Nautel can send out a factory rebuilt module to replace the faulty module Nautel s two locations Canada and the United States provide quick turn around times keeping our cu...

Страница 6: ......

Страница 7: ...1 2 2 1 NxLink Main Page 2 2 2 2 NxLink Main Page Logged In 2 3 2 3 Device Setup Page 2 4 2 4 Setup Equipment Page Configure 2 5 2 5 Setup Equipment Page Configure Customize 2 6 2 6 Device Setup Page...

Страница 8: ......

Страница 9: ...NxLink Technical Instruction Manual Aug 23 22 Release Control Record Issue Date Reason 2 0 23 August 2022 Supports new Netburner device hardware part number UB121 and NxLink SW 2 0 0 software...

Страница 10: ......

Страница 11: ...and event logs retrieval of event logs is not available for all Nautel products contact Nautel for more detail Configurable Email reporting of critical alarms Ability to Save or Email equipment statu...

Страница 12: ......

Страница 13: ...COM settings to Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow Control None NOTE For DHCP networks do not press A in step c After 20 s the DHCP defined IP address should appear on the...

Страница 14: ...e IP Address Enter 2 to set the IP Mask Enter 3 to set the IP Gateway Enter A to set the DNS server address Enter S to save Enter X to exit d Connect the PC to the LAN ensuring that the IP address and...

Страница 15: ...and can be used for initial setup NOTE For security purposes Nautel strongly recommends you change your password see Section 2 4 Users Link b Once logged in see Figure 2 2 the left hand side of the s...

Страница 16: ...rect type be selected You can check the equipment label on the back for equipment type or contact Nautel if you cannot identify your equipment Each piece of equipment that is added is assigned a tab i...

Страница 17: ...for link latency There are eight configurable information pages available for each device scroll down to see all pages and each page can contain up to 16 channels of equipment data Selecting the Custo...

Страница 18: ...ment data Some data are complex indicated in bold text in that they can be selected as a single type but will show as multiple data An example is Active Faults which will show all faults Click Submit...

Страница 19: ...when entering the Email Server fields SMTP Server can be an IP address email server port defaults to port 25 Return Address should be the email address used in the From line of the email received Note...

Страница 20: ...permission level can change their own password and email parameters User Administration Only level that can add remove and modify other users No site configuration or equipment control functions Site...

Страница 21: ...mail will be sent to the user whenever an event with the specified alert level occurs A Minimal email only contains the event type and time A Summary email contains event type and time plus a collecti...

Страница 22: ...hnical instruction manual Issue 2 0 Section 2 Configuration Figure 2 9 User Administration Page Registered User Settings Full NOTE The Email Address field in Change Email Settings supports only one em...

Страница 23: ...the right side of the page If you are not logged in or have insufficient privilege then the status information is shown but controls are not Figure 3 1 Device Status Page It is possible to customize...

Страница 24: ...logged data instead of live data The Event Log tab is not available for all transmitters When viewing log data another tab will appear labelled Live Status Clicking this tab will change the data in t...

Страница 25: ...ation Issue 2 0 Figure 3 3 Save Page Selecting About this equipment displays information about the device being monitored Information includes equipment type and software version s See Figure 3 4 Figu...

Страница 26: ......

Страница 27: ...nal settings are listed in 2 1 step b Follow the steps shown in the typical FTP session see Figure 4 1 use the IP address programmed into the NxLink Upload the file to the NxLink Close the FTP session...

Страница 28: ...Page 4 2 NxLink Technical Instruction Manual Issue 2 0 Section 4 Software Upgrade Figure 4 1 Typical FTP Session Figure 4 2 Ipswitch WSFTP Client...