NX50 Installation Manual
Connecting the station reference ground
Issue 6.1 2021-07-13
Page 4-1
Section 4:
Connecting the station
reference ground
To connect the station reference ground, perform the following steps:
1. Locate the station reference ground stud at the bottom right of the cabinet, as viewed
from the rear.
2. See
. Remove and retain the outer (exterior) nut (2), split washer
(4) and flat washer (3).
3. Attach a continuous, low impedance conductor (minimum four-inch copper strap, or
equivalent wire) between the site’s station reference ground and the transmitter’s
station reference ground stud (1). Ensure the reference ground conductor is at least 3
mm (1/8 in) from the cabinet’s exterior.
4. Reinstall flat washer (3), split washer (4) and nut (2) removed in step 2 on the
transmitter's station reference ground stud (1) and firmly tighten all hardware.
Note:
Proper grounding configuration is critical for protecting transmitter circuitry
from lightning strikes. See the Electrical Requirements section of the NX50 Pre-
Installation Manual or the Recommendations for Transmitter Site Preparation
Manual for information on proper grounding and lightning protection
recommendation. Failure to follow these guidelines may void your warranty.
Содержание NX50
Страница 1: ...NX50 Transmitter Installation Manual Document NHB NX50 INS Issue 6 1 2021 07 13 Status Standard...
Страница 2: ......
Страница 4: ......
Страница 8: ...NX50 Installation Manual Page viii Issue 6 1 2021 07 13...
Страница 12: ...NX50 Installation Manual Preparing for installation Page 1 4 Issue 6 1 2021 07 13...
Страница 24: ...NX50 Installation Manual Unpacking and positioning Page 2 12 Issue 6 1 2021 07 13...
Страница 36: ...NX50 Installation Manual Connecting ac power Page 5 2 Issue 6 1 2021 07 13...
Страница 40: ...NX50 Installation Manual Adjusting the spark gap Page 6 4 Issue 6 1 2021 07 13...
Страница 62: ...NX50 Installation Manual Parts and tools Page 10 4 Issue 6 1 2021 07 13...
Страница 73: ......