Digital inputs
Using the
Inputs
tab (see
, you can configure up to 24 digital inputs
that allow you to remotely control various operational characteristics of the transmitter.
Unless otherwise noted these inputs are only accepted by the transmitter if the remote/local
status is set to
Remote
. That setting can only be made by a local user using the front panel
AUI.
Nautel presets the digital inputs prior to shipping. See the
NV10/NV7.5 Installation Manual
for
a list of default inputs and outputs.
Select the desired digital input (1 through 24) from the list. The
Channel
and
Control
settings
for the selected input, as well as the current logic level (1 or 0), are displayed on the right-hand
side of the page. You can define the
Channel
and
Control
settings as follows:
Channel
You can configure digital inputs 1 through 24 for one of a variety of control inputs. Press the
existing
Channel
bar to display the
Select a Remote
window. From this window select one of
the following options and press
OK
to accept:
•
Not Assigned
. No effect on transmitter operation, regardless of logic level.
•
RF On/Off
. Same as pressing the
RF On
(telling the system to provide RF power, if pos-
sible) or the
RF Off
button on the local AUI. There are 2
inputs configured by default;
one for
Falling Edge, Turn On
and one for
Falling Edge, Turn Off
.
•
Reset
. Causes a system reset. Same as pressing
Reset
button on the local AUI.
•
Inc/Dec RF Power
. Activating these inputs will increment/decrement the preset power
level by a fixed amount (100W). Holding the selection will increment/decrement the
power level by 100W every 1/2 second. There are 2
inputs configured by default; one
for
Active Low, Increase
and one for
Active Low, Decrease.
•
Main Exciter
. Selects the main exciter to operate the transmitter. There are 2 inputs
configured by default; one for
Falling Edge, Set to A
and one for
Falling Edge, Set to B
.
•
Auto Changeover Enabled
. Sets the exciter changeover function to operate automati-
cally. There is only 1 input configured by default; each subsequent activation of the
input will toggle the state (enabled/disabled) e.g.
Falling Edge, Toggle
.
•
Watchdog Asserted.
Allows the user to assert a watchdog reset to the AUI, thus
rebooting the AUI via a hardware parallel remote input (controlled by a third party
remote control unit).
Содержание NV7.5
Страница 2: ......
Страница 4: ......
Страница 8: ...NV10 NV7 5 Operations and Maintenance Manual Page viii Issue 3 4 2016 08 03...
Страница 12: ...NV10 NV7 5 Operations and Maintenance Manual Page xii Issue 3 4 2016 08 03...
Страница 20: ...NV10 NV7 5 Operations and Maintenance Manual Page xx Issue 3 4 2016 08 03...
Страница 28: ...NV10 NV7 5 Operations and Maintenance Manual Description Page 1 8 Issue 3 4 2016 08 03...
Страница 32: ...NV10 NV7 5 Operations and Maintenance Manual Issue 3 4 2016 08 03 Page 1 12...
Страница 38: ...NV10 NV7 5 Operations and Maintenance Manual Operating the transmitter Page 2 6 Issue 3 4 2016 08 03...
Страница 40: ...Issue 3 4 2016 08 03 Page 2 7 Page 2 8 Blank...
Страница 164: ...NV10 NV7 5 Operations and Maintenance Manual Routine maintenance Page 3 10 Issue 3 4 2016 08 03...
Страница 181: ...NV10 NV7 5 Operations and Maintenance Manual List of terms Page 5 4 Issue 3 4 2016 08 03...
Страница 182: ......