Configure Output Logic - AUI
You can configure the active/inactive logic for each of the 16 digital outputs. Click the existing
Logic
bar
to display the applicable drop-down menu options. Some digital output default examples:
If the selected channel is
RF On/Off
, the drop-down options are:
Output Low When RF On
. Logic ‘0’ (low) indicates the output is true (RF is on); Logic ‘1’ (high)
indicates the output is false (RF is off).
Output Low When RF Off
. Logic ‘0’ (low) indicates the output is true (RF is off); Logic ‘1’ (high)
indicates the output is false (RF is on).
If the selected channel is
Local/Remote
, the drop-down options are:
Output Low When Local
. Logic ‘0’ (low) indicates the output is true (Local); Logic ‘1’ (high)
indicates the output is false (Remote).
Output Low When Remote
. Logic ‘0’ (low) indicates the output is true (Remote); Logic ‘1’ (high)
indicates the output is false (Local).
If the selected channel is
Active Exciter
, the drop-down options are:
Output Low When A
. Logic ‘0’ (low) indicates the output is true (A); Logic ‘1’ (high) indicates the
output is false (B).
Output Low When B
. Logic ‘0’ (low) indicates the output is true (B); Logic ‘1’ (high) indicates the
output is false (A).
if the selected channel is
Auto Changeover Enabled
, the drop-down options are:
Output Low When Enabled
. Logic ‘0’ (low) indicates the output is true (Enabled); Logic ‘1’ (high)
indicates the output is false (Disabled).
Output Low When Disabled
. Logic ‘0’ (low) indicates the output is true (Disabled); Logic ‘1’
(high) indicates the output is false (Enabled).
if the selected channel is
Preset: Preset 1
, the drop-down options are:
Output Low When Active
. Logic ‘0’ (low) indicates the output is true (Active); Logic ‘1’ (high)
indicates the output is false (Inactive).
Output Low When Inactive
. Logic ‘0’ (low) indicates the output is true (Inactive); Logic ‘1’ (high)
indicates the output is false (Active).
Click
Apply
to activate changes. Click
Cancel
to cancel changes.
Содержание NV30LT-N
Страница 2: ......
Страница 4: ......
Страница 8: ...NV30LT N OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 1 2015 03 01...
Страница 18: ...NV30LT N OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 10 VERSION 0 1 2015 03 01...
Страница 204: ...NV30LT N OPERATIONS MAINTENANCE MANUAL OPERATING THE TRANSMITTER PAGE 3 2 186 VERSION 0 1 2015 03 01...
Страница 222: ...NV30LT N OPERATIONS MAINTENANCE MANUAL NON STANDARD MAINTENANCE PAGE 3 4 8 VERSION 0 1 2015 03 01...
Страница 224: ...NV30LT N OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 1 2015 03 01...
Страница 225: ......