![Nautel NV30LT-N Скачать руководство пользователя страница 131](http://html1.mh-extra.com/html/nautel/nv30lt-n/nv30lt-n_operation-and-maintenance-manual_3545794131.webp)
NV30LT-N OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.1 2015-03-01
PAGE 3.2.113
Setting Pilot Sample Level
NOTE
: Setting the pilot sample is only available using the front panel display.
From the front panel UI, you can set the level of the pilot sample that is applied to the
PILOT SAMPLE
OUT (A1J4A)
BNC connector on the rear of the controller (A4). To view the
Pilot Sample
screen, select
User Settings -> Pilot Sample
from the
Main Menu
(see
Figure 3.2.94: Pilot Sample Screen
Use the up and down buttons to edit the pilot sample level between 0 and 2.70 V peak-to-peak (in
0.01 V increments). Press the accept (checkmark) button to save the change. Press cancel (
X
) to discard
changes and return to the previous menu.