540
/
838
Nations Technologies Inc.
Tel
:
+86-755-86309900
:
Address: Nations Tower, #109 Baoshen Road, Hi-tech Park North.
Nanshan District, Shenzhen, 518057, P.R.China
be extended or shortened in each bit. Its value can be programmed into 1 to 4 time units. The effective transition is
defined as the first transition from the dominant bit to the recessive bit when CAN itself does not send the recessive
bit.
Note: 1. The time characteristics and resynchronization mechanism of CAN bits are detailed in the ISO11898
standard.
2. In order to improve the CAN bit time accuracy, it is not recommended to use HSI as the clock source.
Figure 20-11 Bit sequence
SYNC_SEG
PHASE_SEG 1
PHASE_SEG 2
One-bit time
Sampling Point
PROP_SEG 1
1 x
t
q
t
BS1
t
BS2
Notes
:
t
PCLK
= time period of the APB1 clock,
t
q
= (CAN_BTIM.BRTP[9:0] + 1) x t
PCLK
,
t
BS1
= t
q
x (CAN_BTIM.TBS1[3:0] + 1),
t
BS2
= t
q
x (CAN_BTIM.TBS2[2:0] + 1),
One-bit time = 1 x t
q
+ t
BS1
+ t
BS2
One-bit time
1
BaudRate =