Reset value
:
0x0000
Bit field
Name
Description
15:7
Reserved
Reserved, the reset value must be maintained
6:4
MMSEL[2:0]
Master Mode Selection
These 3 bits (TIMx_CTRL2. MMSEL [2:0]) are used to select the synchronization information
(TRGO) sent to the slave timer in the master mode. Possible combinations are as follows:
000: Reset –When the TIMx_EVTGEN.UDGN is set or a reset is generated by the slave mode
controller, a TRGO pulse occurs. And in the latter case, the signal on TRGO is delayed compared
to the actual reset.
001: Enable - The TIMx_CTRL1.CNTEN bit is used as the trigger output (TRGO). Sometimes you
need to start multiple timers at the same time or enable slave timer for a period of time.
The counter enable signal is set when TIMx_CTRL1.CNTEN bit is set or the trigger input in gated
mode is high.
010: Update - The update event is selected as the trigger output (TRGO). For example, a master
timer clock can be used as a slave timer prescaler.
011: Compare pulse - Triggers the output to send a positive pulse (TRGO) when the
TIMx_STS.CC1ITF is to be set (even if it is already high), when a capture or a comparison
succeeds.
15
:
1
Reserved
Reserved, the reset value must be maintained.
13.4.4
DMA/Interrupt Enable Registers (TIMx_DINTEN)
Offset address: 0x0C
Reset value: 0x0000
Bit field Name
Description
15:9
Reserved
Reserved, the reset value must be maintained
8
UDEN
Update DMA Request enable
0: Disable update DMA request
1: Enable update DMA request
7:1
Reserved
Reserved, the reset value must be maintained