223
/
838
Nations Technologies Inc.
Tel
:
+86-755-86309900
:
Address: Nations Tower, #109 Baoshen Road, Hi-tech Park North.
Nanshan District, Shenzhen, 518057, P.R.China
Figure 9-12 Schematic diagram of slow
alternate
mode conversion for 1 channel
9.9.6
Rotation trigger Mode
This mode is suitable for injection sequences. The external trigger comes from the multiplexer of ADC1, which is
determined by ADC_CTRL2.EXTJSEL[2:0]. When the first trigger is generated, all injection channels of ADC1 are
converted, when the second trigger is generated, all injection channels of ADC2 are converted, and so on. If ADC1
or ADC2 sets ADC_CTRL1.JENDCIEN, a JENDC interrupt will be generated when the conversion of the injection
sequence of ADC1 or ADC2 is completed. When all injection sequences have been converted, another external
trigger is generated, and the rotation trigger starts again.
Figure 9-13 Rotation triggering: injecting channel g
roups
CH16
ADC1
ADC2
Conversion
Sampling
Trigger
CH1
ENDC(ADC2)
ENDC(ADC1)
14 ADCCLKs
CH1
CH1
CH1
14 ADCCLKs
ADC1
ADC2
Conversion
Sampling
Trigger
JENDC(ADC2)
JENDC(ADC1)
Injection
sequence
Injection
sequence
Injection
sequence
Injection
sequence
Injection
sequence
Injection
sequence