background image

WATER

 

METER

 

MATERIAL

 

&

 

ORDER

 

INFORMATION

 

 
 

 

Supplier

 

Contact:

  

National

 

Meter

 

&

 

Automation,

 

Inc.

 

PO

 

Box

 

8339

 

2250

 

Apollo

 

Way

 

#300

  

Santa

 

Rosa,

 

CA

 

95407

 

 
 
 

Kathy

 

Richards

 

Phone

   

707/575

0700

 

Fax

 

 

707/575

3786

 

Toll

 

Free

 

877/348

0700

 

www.nmaai.com

 

Material

 

(Commercial):

 

 

1.

 

METER

 

BOX

 

Commercial:

 

Oldcastle

 

Christy

 

N36

 

Concrete

 

Meter

 

Box

 

 

2.

 

BADGER

 

METER

 

Residential:

  

Recordall

 

Compound

 

Series

 

Meters

  

Size:

 

2”,

 

3”,

 

4”,

 

6”

 

 

3.

 

ENCODER

 

HR

E

 

High

 

Resolution

 

8

Dial

 

Encoder,

 

registered

 

in

 

cubic

 

foot

 

Note:

 

Two

 

(2)

 

encoders

 

will

 

be

 

required

 

for

 

Compound

 

Meters

 

(a

 

high

 

side

 

&

 

a

 

low

 

side).

 

Please

 

see

 

table

 

below

 

for

 

model

 

numbers.

 

 

Compound

 

Meter

 

Size

 

High

 

Side

 

Model

 

#

 

(Placed

 

on

 

Short

 

side

 

of

 

meter)

 

Low

 

Side

 

Model

 

#

 

(Placed

 

on

 

Taller

 

side

 

of

 

meter)

 

2”

 

T200

 

M25

 

(or

 

also

 

labeled

 

Low

 

2,3)

 

3”

 

M450

 

M25

 

(or

 

also

 

labeled

 

Low

 

2,3)

 

4”

 

M1000

 

M35

 

(or

 

also

 

labeled

 

Low

 

4,6)

 

6”

 

M2000

 

M35

 

(or

 

also

 

labeled

 

Low

 

4,6)

 

 

 

 

4.

 

TRANSPONDER/ENDPOINT

 

ORION

 

Cellular

 

Endpoint

 

with

 

Nicor

 

Connector

 

Note:

 

Two

 

(2)

 

endpoints

 

will

 

be

 

required

 

for

 

Compound

 

meters

 

(hi/low).

 

 

5.

 

&

 

6.

  

MOUNTING

 

KITS

 

&

 

LIDS

  

(Two

 

mounting

 

kits,

 

one

 

for

 

each

 

endpoint)

 

 

For

 

Meter

 

boxes

 

installed

 

in

 

grass

 

&

 

landscaping

 

or

 

non

traffic

 

areas

 

o

 

Through

the

Lid

 

Install

 

Kits

 

(64394

024)

  

o

 

Concrete

 

Lid:

 

Oldcastle

 

N36RP

 

Concrete

 

Lid

 

marked

 

"Water"

 

w/

 

probe

 

holes

 

 

 

For

 

Meter

 

boxes

 

that

 

will

 

need

 

a

 

drive

over

 

lid

 

in

 

traffic

 

areas,

 

i.e.

 

alleys

 

&

 

driveways

 

o

 

Below

the

Lid

 

with

 

Knuckles

 

Install

 

Kits

 

(64394

003)

 

o

 

Fiberlyte

 

Lid

 

(FL

 

36D

 

marked

 

“Water”)

 

Содержание T200

Страница 1: ...Size High Side Model Placed on Short side of meter Low Side Model Placed on Taller side of meter 2 T200 M25 or also labeled Low 2 3 3 M450 M25 or also labeled Low 2 3 4 M1000 M35 or also labeled Low 4...

Страница 2: ...ector endpoint side with the corresponding projection on the other encoder side and push the ends together for the correct fit See 308 In line connector Figure 2 With Nicor in line connectors hold the...

Страница 3: ...nut onto the tube threads as shown 2 Insert the endpoint tube through the bottom of the lid 3 Screw the top cap onto the endpoint tube threads as shown and tighten 4 Tighten the lock nut against the b...

Страница 4: ...ND PRIOR TO ATTACHING THE ENDPOINT TO AVOID DAMAGE 2 Once in the ground secure the mounting bracket on the appropriate rebar or pipe using the enclosed washer wing nut and hex head bolt provided with...

Страница 5: ...RCS UM 00076 EN 04 June 2016 Recordall Compound Series Meter Lead Free Bronze Alloy Sizes 2 3 4 6 NSF ANSI Standards 61 and 372 Certified User Manual...

Страница 6: ...Page ii Recordall Compound Series Meter Lead Free Bronze Alloy Sizes 2 3 4 6 June 2016 RCS UM 00076 EN 04...

Страница 7: ...nd Assemblies 12 Removing the High Flow Turbo Meter Head Assembly 12 Removing the Turbo Measuring Element Assembly from the Cover Plate 14 Removing the Magnet Carrier Top Gear Set 14 Removing the Stra...

Страница 8: ...Page iv Recordall Compound Series Meter Lead Free Bronze Alloy Sizes 2 3 4 6 June 2016 RCS UM 00076 EN 04...

Страница 9: ...rs Product Data Sheet contains information on operating principle meter construction materials tolerances and specifications The Recordall Compound Series Meters Parts List contains part numbers part...

Страница 10: ...s in pipe direction or valving resulting in more accurate registration Contact your Badger Meter representative for information on Recordall Plate Strainers Avoid locating the meter in close quarters...

Страница 11: ...equal in size to the meter is required upstream of the meter Additional length is required if a sharp contraction or an eccentric reducer rather than a concentric tapered reducer is used Installing t...

Страница 12: ...er Figure 4 2 adapter with a 2 round meter Figure 5 4 adapter Figure 6 4 with a 4 meter Description Part Number 2 Elliptical Flange Adapter Kit 64186 001 2 Round Flange Adapter Kit 64186 002 4 Flange...

Страница 13: ...n Now open all applicable service valves Check the flow rate to verify that the flow does not exceed the maximum continuous duty specification The rate of flow can be quickly checked by timing the qua...

Страница 14: ...e added together to determine the total flow through the meter Compare this to that recorded by the test meter or test tank If more than one revolution of the high flow test circle occurs take new rea...

Страница 15: ...aning Clean all dirt grease moisture or other foreign material from the exterior of the meter After cleaning rinse thoroughly with water In the event that system pressure has been reduced and the upst...

Страница 16: ...DO SO CAN LEAD TO THE HEAD BEING EJECTED FROM HOUSING CAUSING PERSONAL INJURY AND OR PROPERTY DAMAGE 1 Loosen each of the High Flow Turbo Head Assembly bolts about 1 1 2 turns Do not completely remov...

Страница 17: ...bottom bearing Calibration ring rear Rotor Calibration ring front Nose cone setscrew Cage setscrew 1 Cage seal Nose cone straightening vane assembly 2 Calibration shaft seal plug Calibration shaft lo...

Страница 18: ...in access to them remove the measuring element from the cover Removing the upstream nose cone provides access to the rotor calibration ring and the transmission assembly To remove the nose cone 1 Unsc...

Страница 19: ...NG 6 Figure 11 Calibration ring linkage assemblies Reassembling the Calibration Mechanism 1 Align the pin on the perimeter of the calibration ring with the arrow tip located on the nose cone assembly...

Страница 20: ...ng pins are an integral part of the straightening vane and nose cone assembly Wear or damage would require the replacement of this component Reassembling the Rotor and Bearings 1 Install the rear nose...

Страница 21: ...and out of the bottom bearing then slide shaft downward and diagonally out towards you to remove it from the nose cone cage assembly 7 Holding cage firmly with one hand rotate the nose cone clockwise...

Страница 22: ...the Low Flow Cover Assembly bolts about 1 1 2 turns Do not completely remove the bolts 2 If the O ring between the Low Flow Cover Assembly and the housing is secure and not leaking pry the Measuring...

Страница 23: ...magnet in the meter head is clean Valve Assembly Removing the Valve Assembly With the cover assembly removed the valve assembly is exposed for service 1 Remove the lock pawl see Figure 14 2 Turn the v...

Страница 24: ...stic Rotor Thrust Bearing Sapphire jewels Rotor Bearing Pivots Passivated 316 stainless steel Calibration Mechanism Stainless steel thermoplastic Measuring Chamber Disc Thermoplastic High Flow Valve S...