manualshive.com logo in svg
background image

NI WSN-3230/3231 User Guide and Specifications

34

ni.com

Online Product Certification

Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. 
To obtain product certifications and the DoC for this product, visit 

ni.com/certification

, search by 

model number or product line, and click the appropriate link in the Certification column.

Environmental Management

NI is committed to designing and manufacturing products in an environmentally responsible manner. 
NI recognizes that eliminating certain hazardous substances from our products is beneficial to the 
environment and to NI customers.

For additional environmental information, refer to the 

NI and the Environment

 Web page at 

ni.com/

environment

. This page contains the environmental regulations and directives with which NI 

complies, as well as other environmental information not included in this document.

Waste Electrical and Electronic Equipment (WEEE)

EU Customers

At the end of the product life cycle, all products 

must

 be sent to a WEEE recycling 

center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, 
and compliance with WEEE Directive 2002/96/EC on Waste and Electronic Equipment, visit 

ni.com/environment/weee

.

Battery Replacement and Disposal

Battery Directive

After replacement, recycle the old battery. For information about the available 

collection and recycling scheme (and your nearest National Instruments Branch Office) or on Battery 
Directive compliance (Directive 2006/66/EC of the European Parliament and Council) in a particular 
EU country visit 

ni.com/company/citizenship/product.htm#battery

.

Magyar 
[Hungarian]

Alulírott, 

National Instruments

 nyilatkozom, hogy a NI WSN-3230/3231

 

megfelel a 

vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.

Polski 
[Polish]

Niniejszym 

National Instruments

. o

ś

wiadcza, 

ż

e NI WSN-3230/3231 jest zgodny z 

zasadniczymi wymogami oraz pozosta

ł

ymi stosownymi postanowieniami Dyrektywy 

1999/5/EC.

Português 
[Portuguese]

National Instruments

 declara que este NI WSN-3230/3231

 

está conforme com os 

requisitos essenciais e outras disposições da Directiva 1999/5/CE.

Slovensko 
[Slovenian]

National Instruments 

izjavlja, da je ta NI WSN-3230/3231 v skladu z bistvenimi zahtevami 

in ostalimi relevantnimi dolo

č

ili direktive 1999/5/ES.

Slovensky 
[Slovak]

National Instruments

 týmto vyhlasuje, _e NI WSN-3230/3231 sp

ĺň

a základné po_iadavky 

a všetky príslušné ustanovenia Smernice 1999/5/ES.

Suomi 
[Finnish]

National Instruments

 vakuuttaa täten että NI WSN-3230/3231 tyyppinen laite on direktiivin 

1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.

Svenska 
[Swedish]

Härmed intygar 

National Instruments

 att denna NI WSN-3230/3231

 

står I 

överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser 
som framgår av direktiv 1999/5/EG.

Íslenska 
[Icelandic]

Hér með lýsir 

National Instruments

 yfir því að NI WSN-3230/3231 er í samræmi við 

grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC.

Norsk 
[Norwegian]

National Instruments

 erklærer herved at utstyret NI WSN-3230/3231

 

er i samsvar med de 

grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF.

Cd/Hg/P

b

Содержание WSN-3230

Страница 1: ...o form a wireless sensor network Figure 1 NI WSN System Components The NI WSN system receives and analyzes distributed sensor data through one or more NI WSN gateways up to 36 NI WSN nodes per gateway...

Страница 2: ...ts Caution Do not operate the NI WSN product in a manner not specified in the user manual or operating instructions Product misuse can result in a hazard You can compromise the safety protection built...

Страница 3: ...ion Caution Do not disconnect the power supply wires and connectors from the device unless power has been switched off Caution Do not install or remove the device unless power has been switched off Ca...

Страница 4: ...t Related Documentation Check ni com manuals for the most recent documentation For a complete list of documentation related to the NI WSN system refer to ni com info and enter rdwsnrd or refer to ni c...

Страница 5: ...nnection 1 8 in flathead and number 2 Phillips screwdrivers NI WSN 1 3 or later Host PC running Windows 7 Vista XP NI LabVIEW 2011 32 bit or later NI LabVIEW WSN Module 2011 or later NI 9792 WSN Real...

Страница 6: ...such as the 18 terminal detachable screw terminal connector Attaching the NI WSN 3282 DIN Rail Optional You can mount the NI WSN 3230 3231 on a standard 35 mm DIN rail using a NI WSN 3282 DIN rail cl...

Страница 7: ...IN Rail Installation 2 Insert one edge of the DIN rail into the deeper opening of the DIN rail clip as shown in Figure 5 Figure 5 DIN Rail Clip Installation 3 Press down firmly on the NI WSN 3230 3231...

Страница 8: ...unt accessory to attach the NI WSN 3230 3231 device to a panel or other flat surface The NI WSN 3281 panel mount accessory also includes a magnetic mount for attaching the NI WSN 3230 3231 device to m...

Страница 9: ...ount accessory using the integrated magnet 2 Slide the NI WSN 3230 3231 device into the panel mount accessory as shown in Figure 7 3 Slide the retention clip down and tighten the panel mount knob to s...

Страница 10: ...hree number 8 or M4 pan head screws in the mounting panel leaving 0 1 in space under the head of each screw Refer to Figure 2 for the correct hole pattern and dimensions 2 Slide the NI WSN 3230 3231 d...

Страница 11: ...ing the hardware install the following software in the following order 1 NI LabVIEW 2011 or later 2 NI LabVIEW Real Time Module 2011 or later required for NI 9795 and NI 9792 support 3 NI RIO 4 0 or l...

Страница 12: ...compartment cover as shown in Figure 10 Figure 10 NI WSN 3230 3231 Battery Compartment Caution Using the incorrect battery type creates an explosion risk Do not use rechargeable batteries Refer to th...

Страница 13: ...To connect an external power supply to the NI WSN 3230 3231 complete the following steps 1 Remove the 2 position mini combicon plug from the device Loosen the retaining screws if necessary Figure 11 2...

Страница 14: ...WSN 3230 3231 device interface Figure 12 NI WSN 3230 3231 Node Interface 1 Antenna 2 WSN Connect Button 3 Signal Strength Status LEDs 4 User LED 5 Battery Slots Polarity Indicators 6 I O Connector 7...

Страница 15: ...us Signal Strength LEDS 1 4 blink twice and then display the signal strength for three seconds LED 1 4 OFF Low Signal LED 1 ON LED 2 4 OFF Poor LED 1 2 ON LED 3 4 OFF Fair LED 1 3 ON LED 4 OFF Good LE...

Страница 16: ...node You can send and receive serial traffic parse and process strings and selectively send data wirelessly back to your host system The sample interval of the node and how the node interacts with ser...

Страница 17: ...ng the RS 232 Port The NI WSN 3230 has one 18 position combicon screw terminal for connectivity to RS 232 DIO and sensor power Figure 13 NI WSN 3230 Pinout 1 0 2 3 4 5 6 7 9 8 10 11 12 13 14 15 16 17...

Страница 18: ...e Auto Mode In this mode the transmitter is enabled automatically when needed and disabled as soon as transmission is finished The receivers are disabled whenever the transmitter is enabled to avoid t...

Страница 19: ...tes per serial message 10 Values Single Precision sent back to Gateway per sampling interval 2 Test Conditions 9600 Baud 50 Bytes per Serial Message Battery Life Years 4 0 0 5 1 1 5 2 2 5 3 3 5 600 50...

Страница 20: ...de Note Use the Node Properties dialog box in the LabVIEW Project Explorer window to change DIO settings The NI WSN 3230 3231 device has two bi directional digital I O channels Each channel supports e...

Страница 21: ...2 wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI WSN 3230 3231 Note You can connect only one external DIO PWR supply to the NI WSN 3230 3...

Страница 22: ...the NI WSN 3230 3231 in Drive High Mode Drive Low Sinking Drive Low Sinking mode is for devices that require low side drive or a sinking output When using this mode The DIOx terminal is pulled to DGND...

Страница 23: ...inking and Sourcing When using Drive High and Low Sinking and Sourcing mode Connect the device to DIOx and connect the device common to the DGND terminal corresponding to that DIOx terminal The DIOx t...

Страница 24: ...nd can reduce battery life Digital I O Protection The high side switch on each I O channel has short circuit protection The low side switch on each I O channel is oversized to be able to withstand hig...

Страница 25: ...t any time Figure 23 shows the sensor power circuit connected to a device Figure 23 External Sensor Connected to the NI WSN 3230 3231 Make sure the device you are connecting is compatible with the NI...

Страница 26: ...RX CTS 15 V Data line ESD protection human body model 8 kV Overvoltage protection 30 VDC RS 485 Maximum cable length 1 2 km 4 000 ft Baud rate standard baud rates only 300 600 1200 1800 2400 4800 720...

Страница 27: ...A High level OFF input voltage 6 V Low level OFF input current 1 mA Input current TTL Logic and Contact Closure modes 375 A at 30 V 110 A at 5 V 80 A at 3 V Contact Closure mode pull up current 175 A...

Страница 28: ...Number of flash erase cycles per sector 100 000 Wireless Characteristics Radio mode IEEE 802 15 4 RF data rate 250 Kbps Range Americas Up to 300 m International Up to 150 m Frequency band1 ISM 2 4 GHz...

Страница 29: ...al impact battery performance For more information refer to ni com info and enter WSNBatterylife External Power Caution You must use a UL Listed ITE power supply marked LPS with the NI WSN 3230 3231 T...

Страница 30: ...comply with the radio frequency radiation exposure guidelines in an uncontrolled environment this equipment should be installed and operated with at least 20 cm between the radiator and the person s b...

Страница 31: ...ncy energy for the treatment of material or inspection analysis purposes Note For EMC certification and additional information refer to the product label or the Online Product Certification section CE...

Страница 32: ...kunt u contact opnemen met BIPT Dans le cas d une utilisation priv e l ext rieur d un b timent au dessus d un espace public aucun enregistrement n est n cessaire pour une distance de moins de 300 m P...

Страница 33: ...struments declara que el NI WSN 3230 3231 cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE Greek National Instruments NI WSN 323...

Страница 34: ...liance Directive 2006 66 EC of the European Parliament and Council in a particular EU country visit ni com company citizenship product htm battery Magyar Hungarian Alul rott National Instruments nyila...

Страница 35: ...12 Taiwan R O C Where to Go for Support The National Instruments Web site is your complete resource for technical support At ni com support you have access to everything from troubleshooting and appli...

Отзывы: