Appendix E
Front Panel and Connectors
©
National Instruments Corporation
E-5
VXIpc 800/700 Series User Manual
Keyboard and Mouse
Figure E-4 shows the location and pinouts for the keyboard connector
on the VXIpc 800/700 Series, and the mouse connector on the
VXIpc-800. For the VXIpc-700 you need to use the COM1 serial port
if you want to connect a mouse. Table E-2 gives the name and
description for the keyboard and mouse connector signals.
Amp manufactures a mating connector with part numbers 212437-4
(housing), 212435-7 (ferrule), and 66735-4 (pin contact).
Figure E-4. Keyboard and Mouse Connectors Location and Pinout
Table E-2. Keyboard and Mouse Connector Signals
Pin
Signal Name
Signal Description
1
DATA
Data
2
NC
Not Connected
3
GND
Ground
4
+5V
+5 volts
5
CLK
Clock
6
NC
Not Connected
Keyboard
Mouse
1
2
4
3
5
6
1
2
4
3
5
6
Keyboard
1
2
4
3
5
6
Keyboard
1
2
4
3
5
6
2
1
a. VXIpc-800
b. VXIpc-745