National Instruments Corporation
A-1
VXI-1394 User Manual for Windows
A
Specifications
This appendix lists the specifications for the VXI-1394 module.
VXI Requirements
VXIbus configuration space................... 64 B
A24 or A32 space................................... Programmable
Default ............................................ None
Power Requirement
+5 V
Typical ............................................ 2.23 A
Maximum (fused) ........................... 7 A
–5.2 V
Typical ............................................ 176 mA
Maximum (fused) ........................... 1 A
–2 V
Typical ............................................ 89.5 mA
Maximum (fused) ........................... 1 A
+12 V
Typical ............................................ 750 µA
Maximum (fused) ........................... 1 A
Physical
Dimensions
Fully enclosed, shielded VXI C-size board
233.35 mm
×
340 mm (9.187 in.
×
13.386 in.)
Weight
VXI-1394 ........................................ 1.11 kg (2.45 lb)
(No DRAM installed)