Chapter 5
Using the SCXI-1102/B/C
©
National Instruments Corporation
5-5
Analog Input»General Properties»
Advanced»Range»Low
AI.RNG.Low
Specifies the lower limit of the
E/M Series DAQ device input
range in voltage.
Analog Input»General Properties»
Advanced»Gain and Offset»Gain Value
AI.Gain
Specifies a gain factor to apply to
the signal conditioning portion
of the channel.
Table 5-2.
NI-DAQmx Thermocouple Measurement Properties
Property
Short Name
Description
Analog Input»Temperature»
Thermocouple»Type
AI.Thermcpl.Type
Specifies the type of thermocouple
connected to the channel.
Analog Input»Temperature»
Thermocouple»CJC Source
(read only)
AI.Thermcpl.CJCSrc
Indicates the source of
cold-junction compensation.
Analog Input»Temperature»
Thermocouple»CJC Value
AI.Thermcpl.CJCVal
Specifies the temperature of the
cold-junction if the CJC source is
constant value.
Analog Input»Temperature»
Thermocouple»CJC Channel
(read only)
AI.Thermcpl.CJCChan
Indicates the channel that acquires
the temperature of the cold
junction if CJC is channel.
Analog Input»Temperature»
Advanced»Force Read From
Channel
AI.ForceReadFromChan
Specifies whether to return the
reading from the CJC channel
during a read operation.
Table 5-3.
NI-DAQmx RTD Measurement Properties
Property
Short Name
Description
Analog Input»Temperature»
RTD»Type
AI.RTD.Type
Specifies the type of RTD
connected to the channel.
Analog Input»Temperature»
RTD»R0
AI.RTD.R0
Specifies the resistance in ohms of
the sensor at 0
°
C.
Table 5-1.
NI-DAQmx Voltage Measurement Properties (Continued)
Property
Short Name
Description