SCXI-1303 Installation Guide

Warning

Connecting an external ground-referenced signal with the 10 

 bias resistor 

network in place may cause permanent damage to the resistor network and the 
traces on the SCXI-1303 printed circuit board. National Instruments is 

NOT

 liable 

for any damage or injuries resulting from improper signal connections.

Signal Connection

When connecting your signals to the SCXI-1303, follow the labeling on the 
SCXI-1303 for the appropriate module, as indicated in Figure 4.

To connect the signal to the terminal block, perform the following steps, 
referring to Figures 3 and 4 as necessary:

1.

Unscrew the top cover screws and remove the cover.

2.

Loosen the strain-relief screws and remove the strain-relief bar.

3.

Run the signal wires through the strain-relief opening. You can add 
insulation or padding if necessary.

4.

Prepare your signal wire by stripping the insulation no more than 
7 mm.

Table 2.  

Selecting the Appropriate Resistor Networks

Module

Bias Resistor

Pullup 

Resistor

Source 

Impedance

Signal

(Floating or 

Ground-

referenced)

Open 

Thermocouple 

Detection?

Comments

SCXI-1102
/B/C

10 M

10 M

Low

Both

Yes

Recommended 
configuration for the 
SCXI-1102/B/C

10 

10 M

Low

Floating

Yes

Factory-shipping 
configuration

10 

None

High or low

Floating

No

None

None

High or low

Ground-
referenced

No

SCXI-1100

10 M

10 M

Not recommended

10 

10 M

Low

Floating

Yes

Factory-shipping 
configuration

10 

None

High or low

Floating

No

None

None

High or low

Ground-
referenced

No

low source impedance 

50

 Ω

high

 

source impedance >50

 Ω

Содержание SCXI-1303

Страница 1: ...rature gradients across the screw terminals when you measure with thermocouples The terminal block has 78 screw terminals for easy connection Thirty two pairs of screw terminals connect to the 32 diff...

Страница 2: ...se numbers The 10 resistor network is labeled 100 10 100 the 10 M resistor network is labeled 106 10 106 Figure 1 shows examples of these resistors Figure 1 Resistor Networks Open Thermocouple Detecti...

Страница 3: ...M 10 pin bused configuration resistor network not supplied and have a sample rate of 20 kHz interchannel delay of 50 s typical With a 10 bias resistor network the current leakage would be 5 A 5 V 1 M...

Страница 4: ...offset Temperature Sensor Output and Accuracy The SCXI 1303 temperature sensor outputs 1 91 to 0 58 V from 0 to 55 C and has an accuracy of 0 5 C over the 15 to 35 C range and 0 9 C over the 0 to 15 a...

Страница 5: ...MPOUT signal Therefore use an average of a large number of samples to obtain the most accurate measurement Noisy environments require more samples for greater accuracy Configuring the Resistor Network...

Страница 6: ...networks Table 2 shows which resistor networks to use for your SCXI module signal type and application Table 1 Channel Input Signals and Resistor Networks Channel Pullup Resistor Network Bias Resisto...

Страница 7: ...d remove the cover 2 Loosen the strain relief screws and remove the strain relief bar 3 Run the signal wires through the strain relief opening You can add insulation or padding if necessary 4 Prepare...

Страница 8: ...earth ground to the earth ground solder lug 8 Reinstall the strain relief bar and tighten the strain relief screws 9 Reinstall the top cover and tighten the top cover screws 10 Connect the terminal bl...

Страница 9: ...eps 1 Connect the module front connector to its mating connector on the terminal block 2 Tighten the top and bottom thumbscrews on the back of the terminal block to hold it securely in place Note For...

Страница 10: ...from 15 to 35 C Output 1 91 to 0 58 V from 0 to 55 C Temperature Sensor Circuit Diagram The circuit diagram in Figure 5 provides optional details about the SCXI 1303 temperature sensor Figure 5 Tempe...

Страница 11: ......

Отзывы: