2-24
|
ni.com
Chapter 2
Basic Functions
Specifying CF01 to CF36, CF 41 to CF52 CONFIG Settings
Note
Excludes CF00 (Reset panel settings) and CF40 (Resets or applies LAN
interface settings).
Complete the following steps to specify the CONFIG settings.
1.
Press CONFIG.
The CONFIG key lights, and the SET key blinks. The ammeter displays the parameter
number—CF00. The voltmeter displays the corresponding setting—rSt.
2.
Press CONFIG or turn the CURRENT knob to select the number of the parameter that you
want to set.
When you press CONFIG, the RMX programmable power supply switches between the
parameter ranges in the following order.
CF00 -->CF20 -->CF30 -->CF40 -->CF50 -->measured value display
When you turn the CURRENT knob, the RMX programmable power supply increments
through the parameter numbers within the currently selected parameter range.
Tip
Press CONFIG or turn the CURRENT knob to switch between the parameter
numbers. These two methods switch between the parameter numbers differently.
3.
Turn the VOLTAGE knob to change the value of the parameter.
4.
To specify or display other parameters, repeat steps 2 and 3. To stop specifying CONFIG
settings, proceed to step 5.
5.
Continue pressing CONFIG until the measured value display appears. Alternatively, press
OUTPUT or PWR DSPL. If you are configuring a slave unit, press CONFIG or
PWR DSPL.
Some CONFIG parameters will be applied immediately after you set them, some will be
applied after you restart the RMX programmable power supply, and some will be applied
after you execute CF40 “APPL”.