National Instruments REM-11178 Скачать руководство пользователя страница 11

Caution

 

Tilting the module when removing it from the DIN rail will damage

the contacts.

Removing Bus Connectors

Complete the following steps to remove bus connectors from the DIN rail.

What to Use

Flathead Screwdriver

What to Do

Note

 

You must remove the preceding module before removing the bus connector.

1

3

2

1.

Slide the bus connector away from the preceding bus connector at least 5.0 mm (0.20 in.).

2.

Insert the screwdriver and loosen both latches on one side of the DIN rail.

3.

Rotate the bus connector to remove it from the DIN rail.

Note

 

If you want to remove a bus connector in the middle of the system, you

must remove any modules or bus connectors following the desired connector or
slide them along the DIN rail at least 15.0 mm (0.60 in.).

REM-11178 Getting Started Guide

  | 

© National Instruments

  | 

11

Содержание REM-11178

Страница 1: ...ght not meet the same safety ratings Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Caution Do not operate the REM 11178 in a...

Страница 2: ...nstallations when the product is connected to a peripheral device or test object or if the product is used in residential or commercial areas To minimize interference with radio and television recepti...

Страница 3: ...trap or by holding a grounded object such as your computer chassis 1 Touch the antistatic package to a metal part of the computer chassis 2 Remove the device from the package and inspect the device fo...

Страница 4: ...ED indicators Table 1 Module Function Labels Label Color Module Function Blue Digital input Red Digital output Green Analog input thermocouple Yellow Analog output White Bus coupler power module Insta...

Страница 5: ...bus connector Note A bus connector will not attach to a preceding bus connector with a mounted module Remove the preceding module before installing additional bus connectors 3 Repeat Steps 2 and 3 for...

Страница 6: ...directly onto the bus connector and DIN rail until it clicks into place Caution Tilting the module when mounting it on the DIN rail will damage the contacts Installing Spring Terminal Blocks What to U...

Страница 7: ...ut modules internally jumpered b1 b2 Blue GND Reference potential of the supply voltage internally jumpered 00 to 07 Orange DO0 to DO7 Digital outputs 0 to 7 10 to 17 Orange DO8 to DO15 Digital output...

Страница 8: ...78 is not part of the configuration Red Solid The REM 11178 has lost connection to the Bus Coupler Flashing The REM 11178 has lost connection to the preceding adjacent module Off The REM 11178 is in r...

Страница 9: ...he power supply UO have the same voltage Note For information about fuse ratings for the REM 11178 refer to the device datasheet on ni com manuals Connection Guidelines Make sure that devices you conn...

Страница 10: ...ctor from the module Removing the REM 11178 Remove all connections before removing the REM 11178 either by disconnecting the cables or removing the spring terminal block What to Use Flathead Screwdriv...

Страница 11: ...ector 1 3 2 1 Slide the bus connector away from the preceding bus connector at least 5 0 mm 0 20 in 2 Insert the screwdriver and loosen both latches on one side of the DIN rail 3 Rotate the bus connec...

Страница 12: ...rs Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration facilitates technical...

Страница 13: ...it the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers email addresses and current events REM 11178...

Страница 14: ...party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain rel...

Отзывы: