background image

GETTING STARTED GUIDE

NI REM-11102

Current Input Module for Remote I/O

This document explains how to connect to the REM-11102.

Note

 

The guidelines in this document are specific to the REM-11102. The other

components in the system might not meet the same safety ratings. Refer to the
documentation for each component in the system to determine the safety and EMC
ratings for the entire system.

Caution

 

Do not operate the REM-11102 in a manner not specified in this

document. Product misuse can result in a hazard. You can compromise the safety
protection built into the product if the product is damaged in any way. If the product
is damaged, return it to NI for repair.

Содержание REM-11102

Страница 1: ...ght not meet the same safety ratings Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Caution Do not operate the REM 11102 in a...

Страница 2: ...romagnetic environment This product is intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or tes...

Страница 3: ...g the device ground yourself using a grounding strap or by holding a grounded object such as your computer chassis 1 Touch the antistatic package to a metal part of the computer chassis 2 Remove the d...

Страница 4: ...ED indicators Table 1 Module Function Labels Label Color Module Function Blue Digital input Red Digital output Green Analog input thermocouple Yellow Analog output White Bus coupler power module Insta...

Страница 5: ...bus connector Note A bus connector will not attach to a preceding bus connector with a mounted module Remove the preceding module before installing additional bus connectors 3 Repeat Steps 2 and 3 for...

Страница 6: ...the underside of the module 2 Press the REM 11102 directly onto the bus connector and DIN rail until it clicks into place Caution Tilting the module when mounting it on the DIN rail will damage the c...

Страница 7: ...ly for analog modules internally jumpered b1 b2 Blue GND Reference potential of the supply voltage internally jumpered 00 to 03 Orange AI0 to AI3 Positive voltage connection for channel 0 to 3 10 to 1...

Страница 8: ...detect a valid cycle after power on Flashing The REM 11102 is not part of the configuration Red Solid The REM 11102 has lost connection to the Bus Coupler Flashing The REM 11102 has lost connection t...

Страница 9: ...r Off On Note The reported error depends on the measuring range For information about input scaling refer to the device datasheet on ni com manuals Connecting the REM 11102 Figure 4 REM 11102 Current...

Страница 10: ...utside the specified tolerance limits in environments subject to heavy noise Connect the cable shield to functional earth ground immediately after the cables enter the control cabinet Connect the cabl...

Страница 11: ...r from the module Removing the REM 11102 Remove all connections before removing the REM 11102 either by disconnecting the cables or removing the spring terminal block What to Use Flathead Screwdriver...

Страница 12: ...us connector 1 3 2 1 Slide the bus connector away from the preceding bus connector at least 5 0 mm 0 20 in 2 Insert the screwdriver and loosen both latches on one side of the DIN rail 3 Rotate the bus...

Страница 13: ...t ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration facilitates technical support...

Страница 14: ...Instruments Patent Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export C...