manualshive.com logo in svg
background image

Table 1.

 NI PXIe-8830mc Slot Type Compatibility

NI PXI Express Product

PXI Express Chassis

Controller 

Peripheral 

Hybrid 

H

 

 

 

 

NI PXIe-8830mc

X

X

6.

Align the NI PXIe-8830mc with the card guides on the top and bottom of the slot. Hold
the handle as you slowly slide the module into the chassis until the handle catches on the
injector/ejector rail.

Caution

 

Do not raise the injector/ejector handle as you insert the NI

PXIe-8830mc. It will not insert properly unless the handle is in its downward
position so that it does not interfere with the injector/ejector rail on the chassis.

7.

Raise the injector/ejector handle until the module firmly seats into the backplane
receptacle connectors. The front panel of the NI PXIe-8830mc should be even with the
front panel of the chassis.

8.

Tighten the bracket-retaining screws on the top and bottom of the front panel to secure
the NI PXIe-8830mc to the chassis.

9.

Replace or close any doors or covers to the chassis.

Powering On the PXImc System

The NI PXIe-8830mc powers on automatically when the chassis is powered on. To power on
the NI PXIe-8830mc, turn on the chassis. The NI PXIe-8830mc boots up to OS when the
system controller boots up when the chassis is powered on.

Powering Off the PXImc System

The NI PXIe-8830mc powers off automatically when the chassis is powered off. You also can
power off the NI PXIe-8830mc by shutting down the system controller.

Software Installation and Configuration

The NI PXIe-8830mc requires the NI-PXImc driver software to enable its features. Refer to
the 

readme.html

 file on the NI-PXImc driver DVD for software installation instructions.

LabVIEW RT Installation

This section explains software installation and switch configuration for LabVIEW RT on your
PXImc processor module.

LabVIEW RT Software Installation

The following section describes the necessary steps to set up your PXImc processor module to
run LabVIEW Real-Time. In this section you will configure the processor module boot mode,
verify or change IP settings, and install LabVIEW Real-Time software.

Complete the following steps to install the LabVIEW RT software.
1.

Boot the NI PXImc processor module into the real-time operating system.
The PXImc processor module automatically boots into LabVIEW RT Safe Mode when no
software is installed. LabVIEW RT Safe Mode loads with the basic real-time operating

4

  | 

ni.com

  | 

NI PXImc Devices Getting Started Guide

Содержание PXImc Series

Страница 1: ...ing the NI PXIe 8830mc from a PXI Express Chassis 9 Cleaning 9 Common Configuration Questions 10 General Questions 10 Upgrade Information 10 Troubleshooting 11 What if the processor module does not bo...

Страница 2: ...t electrostatic discharge from damaging device components To prevent such damage when handling the device ground yourself using a grounding strap or by holding a grounded object such as your computer...

Страница 3: ...your PXI Express chassis 1 Power off your PXI Express chassis but leave it plugged in while installing the NI PXIe 8830mc The power cord grounds the chassis and protects it from electrical damage whil...

Страница 4: ...the chassis The NI PXIe 8830mc boots up to OS when the system controller boots up when the chassis is powered on Powering Off the PXImc System The NI PXIe 8830mc powers off automatically when the cha...

Страница 5: ...plorer Help accessible by browsing to MAX Remote Systems Help LabVIEW Real Time Target Configuration Configuring Network Settings from the help Contents tab Note When any IP or identification settings...

Страница 6: ...ed LabVIEW RT engine After changing the settings or software reboot the processor module with this switch OFF to resume normal operation Switch 3 Disable Startup VI Set this switch to ON to prevent VI...

Страница 7: ...VIEW RT Configuration Switches 1 2 3 4 1 Switch 1 Boot LabVIEW RT 2 Switch 2 Boot Safe Mode 3 Switch 3 Disable Startup VI 4 Switch 4 Reset IP Address NI PXImc Devices Getting Started Guide National In...

Страница 8: ...5 User 2 LED 6 PWR OK FAULT LED 7 Drive LED Front Panel Connectors The following table lists various peripherals and their corresponding NI PXIe 8830mc external connectors bus interfaces and functions...

Страница 9: ...to protect the system USER Two bi color green yellow LEDs USER 1 and USER 2 that you can define to meet the needs of your LabVIEW application DRIVE Indicates when an access to the internal hard disk...

Страница 10: ...ing steps to upgrade the RAM 1 Remove theNI PXIe 8830mc from the PXI Express chassis 2 Locate the DDR4 SO DIMM module on the side of the processor module as shown in the figure 3 Remove the installed...

Страница 11: ...ssor module does not boot Several problems can cause a processor module not to boot Here are some things to look for and possible solutions Things to Notice Ensure that a system controller is installe...

Страница 12: ...of this is a damaged module Try the module in a different chassis or with a different controller Also remove any external cables or terminal blocks connected to the system If the module does not work...

Страница 13: ...nical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using the manuf...

Страница 14: ...atents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user license agreements EULAs and third party...

Отзывы: