National Instruments PXIe-8246 Скачать руководство пользователя страница 6

The PXIe-8246 provides four standard Gigabit Ethernet ports (Port 0 to Port 3) to acquire
images from GigE Vision cameras. When the PXIe-8246 is providing PoE, the LED that
corresponds to the port will be lit.

Table 1. PoE LED Status Definitions

LED Status

Definition

 

 

Red

PoE protection is triggered

1

Green

PoE is operational

Unlit

PoE is off

Table 2. Ethernet LED Status Definitions

LED

Status

Definition

 

 

 

Activity/Link

Unlit

No link has been established

Solid

A link has been negotiated

Blinking

Activity on the link

Speed

Unlit

No link, or 10 Mbps link

Green

100 Mbps link

Amber

1,000 Mbps link

Configuring the PXIe-8246 in MAX

Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX
informs other programs about which NI hardware products are in the system and how they are
configured. MAX is automatically installed with NI Vision Acquisition Software (VAS).
1.

Launch MAX.

2.

In the configuration tree, expand 

Devices and Interfaces

 to see the list of installed NI

hardware.

Installed modules appear under the name of their associated chassis.

3.

Expand your 

Chassis

 tree item.

MAX lists all modules installed in the chassis. Your default names may vary.

Note

 

If you do not see your module listed, press <F5> to refresh the list of

installed modules. If the module is still not listed, power off the system, ensure
the module is correctly installed, and restart.

1

PoE has exceeded the absolute maximum power. To reset the LED, power cycle the system after
the camera/load is removed.

6

  | 

ni.com

  | 

PXIe-8246 Getting Started Guide

Содержание PXIe-8246

Страница 1: ...VAS LabVIEW 2020 Optional software for developing applications NI Vision Builder for Automated Inspection NI Vision Development Module VDM Note Before you begin install and configure your chassis and...

Страница 2: ...ackage and inspect the device for loose components or any other sign of damage Notice Never touch the exposed pins of connectors Note Do not install a device if it appears damaged in any way 3 Unpack...

Страница 3: ...e installation media for system requirements and installation instructions for the NI IMAQdx driver Documentation for the NI IMAQdx driver software is available by selecting Start All Programs Nationa...

Страница 4: ...e black plastic covers from all the captive screws on the module front panel 5 Identify a supported slot in the chassis The following figure shows the symbols that indicate the slot types Figure 1 Cha...

Страница 5: ...ete the following steps 1 Select Start All Programs National Instruments Measurement Automation Explorer to open Measurement Automation Explorer MAX 2 Verify that the camera connected to the PXIe 8246...

Страница 6: ...MAX to configure your NI hardware MAX informs other programs about which NI hardware products are in the system and how they are configured MAX is automatically installed with NI Vision Acquisition So...

Страница 7: ...nsure that all hardware is correctly installed and restart the system 4 Navigate to the Device Manager Right click the Start button and select Device Manager 5 Verify the PXIe 8246 appears in the Devi...

Страница 8: ...ess to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers Visit ni com services for information about the servi...

Страница 9: ...ULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how...

Отзывы: