National Instruments PXIe-8238 Скачать руководство пользователя страница 11

Table 1. SFP+ Connector Signals (Continued)

Pin

Symbol

Name/Description

 

 

 

7

RS0

Rate Select 0; optionally controls SFP+ module receiver

8

Rx_LOS

Receiver Loss of Signal Indication

9

RS1

Rate Select 1; optionally controls SFP+ module transmitter

10

VeeR

Module Receiver Ground

11

VeeR

Module Receiver Ground

12

RD-

Receiver Inverted Data Output

13

RD+

Receiver Non-Inverted Data Output

14

VeeR

Module Receiver Ground

15

VccR

Module Receiver 3.3 V Supply

16

VccT

Module Transmitter 3.3 V Supply

17

VeeT

Module Transmitter Ground

18

TD+

Transmitter Non-Inverted Data Input

19

TD-

Transmitter Inverted Data Input

20

VeeT

Module Transmitter Ground

Note

 

The PXIe-8238 can perform an automatic crossover, thus eliminating the

need for crossover cables.

Table 2. Link/Activity and Speed Indicator LEDs

Link/Activity LED

Speed LED

 

 

 

No Link

Off

Off

Linked—No Activity

Green

Yellow = 1 GbE

Green = 10 GbE

Linked—Activity

Blinking Green

Yellow = 1 GbE

Green = 10 GbE

PXIe-8238 User Manual

  | 

© National Instruments

  | 

11

Содержание PXIe-8238

Страница 1: ...limits for electromagnetic compatibility EMC stated in the product specifications These requirements and limits provide reasonable protection against harmful interference when the product is operated...

Страница 2: ...C industry has improved the available bus bandwidth by evolving PCI to PCI Express PXI is now able to meet even more application needs by integrating PCI Express into the PXI standard By taking advant...

Страница 3: ...ch to a PXI Express system via a high bandwidth low latency PXI Express backplane Gen2 x8 link With the 10Gb Ethernet it allows offloading data from a PXI Express system to an external storage solutio...

Страница 4: ...ing user interfaces a complete ANSI C environment for building your test program logic and a collection of automated code generation tools as well as utilities for building automated test systems moni...

Страница 5: ...x and support for more than two hundred devices on Linux with the NI DAQmx driver you now can create Virtual Instruments based on the Linux OS The NI VISA driver for Linux has improved instrument cont...

Страница 6: ...6 02 mm 2 645 in 67 17 mm 2 296 in 58 32 mm 1 948 in 49 47 mm 0 000 in 0 00 mm 0 249 in 6 33 mm 0 612 in 15 54 mm NI PXIe 8238 ETH 0 LINK ACT LINK ACT SPEED SPEED ETH 1 Electrical Power Rail Typical V...

Страница 7: ...tal Operating Environment Ambient temperature range 0 C to 55 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 6...

Страница 8: ...of the following EMC standards for electrical equipment for measurement control and laboratory use EN 61326 1 IEC 61326 1 Class A emissions Basic immunity EN 55011 CISPR 11 Group 1 Class A emissions E...

Страница 9: ...ize Our Environmental Impact web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not includ...

Страница 10: ...TD VeeT VeeR RS1 Rx_LOS RSO MOD_ABS SCL Tx_Disable SDA Tx_Fault VeeT 10 9 8 7 6 5 4 3 2 20 1 11 12 13 14 15 16 17 18 19 Table 1 SFP Connector Signals Pin Symbol Name Description 1 VeeT Module Transmit...

Страница 11: ...Receiver Ground 15 VccR Module Receiver 3 3 V Supply 16 VccT Module Transmitter 3 3 V Supply 17 VeeT Module Transmitter Ground 18 TD Transmitter Non Inverted Data Input 19 TD Transmitter Inverted Dat...

Страница 12: ...hone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers em...

Отзывы: