background image

To access NI-Digital Pattern Driver documentation, in the 

Start

 menu, navigate to

NI Digital Pattern Documentation

 in the 

National Instruments

 folder. The primary help file

is 

digipat.chm

, and all other help files in the folder are embedded in 

digipat.chm

.

Related Information

Digital Pattern Instrument Examples

 on page 12

Operating the Digital Pattern Instrument

 on page 11

You can operate the PXIe-6570 through use of the Digital Pattern Editor or the supported
ADE of your choice.

Digital Pattern Help

Associated Drivers

NI-DCPower

The NI-DCPower driver is required to use NI-DCPower modules within the Digital Pattern
Editor. For more information about using NI-DCPower modules within the Digital Pattern
Editor, refer to the 

Digital Pattern Help

. Visit 

ni.com/downloads

 to download NI-DCPower.

NI-Sync

The NI-Sync driver is required to support operations using the PXIe-6674T timing and
synchronization module, such as combining comparison results across digital pattern
instruments. For more information about using the PXIe-6674T with digital pattern
instruments, refer to the 

Digital Pattern Help

. Visit 

ni.com/downloads

 to download NI-Sync.

Installing the PXIe-6570

Caution

 

To prevent damage to the PXIe-6570 caused by ESD or contamination,

handle the module using the edges or the metal bracket.

1.

Ensure the AC power source is connected to the chassis before installing the module.

The AC power cord grounds the chassis and protects it from electrical damage while you
install the module.

2.

Power off the chassis.

3.

Inspect the slot pins on the chassis backplane for any bends or damage prior to
installation. Do not install a module if the backplane is damaged.

4.

Remove the black plastic covers from all the captive screws on the module front panel.

5.

Identify the slots you will use in the chassis.

The PXIe-6570 is a two-slot module with two PXI Express backplane connectors. The
module must be installed into two adjacent PXI Express-compatible slots. If you plan to
use the optional PXIe-6674T Timing and Synchronization Module, reserve the PXI
Express System Timing Slot for its placement in the chassis. The following figure shows
the symbols that indicate the slot types.

PXIe-6570 Getting Started Guide

  | 

© National Instruments

  | 

5

Содержание PXIe-6570

Страница 1: ...quirements 2 Unpacking the Kit 2 Kit Contents 3 Preparing the Environment 3 Installing the Software 3 Digital Pattern Editor 4 NI Digital Pattern Driver 4 Associated Drivers 5 Installing the PXIe 6570...

Страница 2: ...ielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input output ports and connected to the product using a shielded cable If unshielded...

Страница 3: ...ver and Digital Pattern Editor media NI part number 785249 03 separately Preparing the Environment Ensure that the environment in which you are using the PXIe 6570 meets the following specifications O...

Страница 4: ...tate of the digital pattern instrument The Digital Pattern Editor is installed when you install NI Digital Pattern Driver For more information refer to the Digital Pattern Help To access Digital Patte...

Страница 5: ...g the PXIe 6674T with digital pattern instruments refer to the Digital Pattern Help Visit ni com downloads to download NI Sync Installing the PXIe 6570 Caution To prevent damage to the PXIe 6570 cause...

Страница 6: ...ure 2 PXIe 6570 Installation 4 3 2 1 1 PXI Express Chassis 2 Ejector Handle in Down Position 3 NI PXI Express Two Slot Module 4 Captive Screw 8 Secure the module front panel to the chassis using the f...

Страница 7: ...68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 GND CAL FORCE GND DIO 0 CAL GND DGS DIO 2 GND DIO 4 RESERVED DIO 6 GND DIO 8 GND DIO 10 GND DIO 1...

Страница 8: ...und Optional DGS for improved accuracy at higher currents in some configurations CAL GND Analog Resource for external calibration 67 CAL FORCE Analog Resource for external calibration 30 60 RESERVED N...

Страница 9: ...il the instrument is reset or calibration succeeds The instrument has detected an unlocked condition on a PLL that might result in incorrect data To clear this error condition reset the instrument pro...

Страница 10: ...operly designed and shielded input output ports and connected to the product using a shielded cable If unshielded cables or accessories are not properly installed and shielded the EMC specifications f...

Страница 11: ...ier MAX assigns to the hardware Use this identifier when programming the PXIe 6570 5 Self test the hardware by selecting the item in the configuration tree and clicking Self Test in the MAX toolbar Th...

Страница 12: ...tions using the PXIe 6570 Digital Pattern Instrument Examples To locate programming and operating examples refer to the following table Table 6 NI Digital Pattern Driver Example Locations Application...

Страница 13: ...nterfaces 2 Expand the Chassis tree to see the list of installed hardware and press F5 to refresh the list 3 If the module is still not listed power off the system ensure that all hardware is correctl...

Страница 14: ...is powered on Applying external signals while the module is powered off may cause damage Disconnect any signals from the PXI Express module front panels 2 Remove any front panel connections from the...

Страница 15: ...ments National Instruments NET Support Digital Pattern Help Worldwide Support and Services The NI website is your complete resource for technical support At ni com support you have access to everythin...

Страница 16: ...oducts technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find informatio...