Making a Measurement
Making a Measurement with LabVIEW
1.
Launch LabVIEW.
2.
Select
Help
»
Find Example
.
3.
Open the example VI that you want to use by selecting
Hardware Input and Output
»
FlexRIO
.
4.
Follow any setup, configuration, and execution instructions in the VI.
Troubleshooting
If an issue persists after you complete a troubleshooting procedure, contact NI technical
support or visit
.
What Should I Do if the PXIe-5785 Doesn't Appear in
MAX?
1.
In the MAX configuration tree, expand
Devices and Interfaces
.
2.
Expand the
Chassis
tree to see the list of installed hardware, and press <F5> to refresh
the list.
3.
If the module is still not listed, power off the system, ensure that all hardware is correctly
installed, and restart the system.
4.
Navigate to the Device Manager.
Operating System
Description
Windows 10/8.1
Right-click the Start button, and select
Device Manager
.
Windows 7
Select
Start
»
Control Panel
»
Device Manager
.
5.
Verify the PXIe-5785 appears in the Device Manager.
a)
Under an NI entry, confirm that a PXIe-5785 entry appears.
Note
If you are using a PC with a device for PXI remote control system,
under
System Devices
, also confirm that no error conditions appear for the
PCI-to-PCI Bridge
.
b)
If error conditions appear, reinstall FlexRIO and the PXIe-5785.
What Should I Do if the PXIe-5785 Fails the Self-Test?
1.
Restart the system.
2.
Launch MAX, and perform the self-test again.
3.
Power off the chassis.
4.
Reinstall the failed module in a different slot.
12
|