background image

Configuring the PXIe-5665 in MAX

Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX

informs other programs about which NI hardware products are in the system and how they are

configured. MAX is automatically installed with NI-RFSA.
1. Launch MAX.
2. In the configuration tree, expand 

Devices and Interfaces

 to see the list of installed NI

hardware.

Note

 

If you are using the PXIe-5665 with the LabVIEW Real-Time Module,

expand 

Remote Systems

. Find your target IP address or name, expand it, and

then expand 

Devices and Interfaces

.

Installed modules appear under the name of their associated chassis.

3. Expand your 

Chassis

 tree item.

MAX lists all modules installed in the chassis. Your default names may vary.

Note

 

If you do not see your module listed, press <F5> to refresh the list of

installed modules. If the module is still not listed, power off the system, ensure

the module is correctly installed, and restart.

4. Record the identifier MAX assigns to the hardware. Use this identifier when

programming the PXIe-5665.

5. Associate the hardware modules that comprise your device.

a) Select the PXIe-5603 or PXIe-5605 that is identified as not configured in the

configuration tree.

b) In the Associated Devices section, select the appropriate module from each system

component drop-down listbox.
For the PXIe-5665, you must associate the PXIe-5622 IF digitizer module and the

PXIe-5653 LO source module with the PXIe-5603 or PXIe-5605 RF downconverter.

c) Click 

Save

 in the MAX toolbar.

Note

 

Module associations may be lost when you move the modules to

different chassis slots.

6. Self-test the device modules by selecting the modules in the configuration tree, and

clicking 

Self-Test

 in the MAX toolbar. Repeat this step for all modules in your

PXIe-5665 system.

22

  | 

ni.com

  | 

PXIe-5665 Getting Started Guide

Содержание PXIe-5665

Страница 1: ...PXIe 5665...

Страница 2: ...therwise specified the instructions for the PXIe 5665 in this document refer to both the PXIe 5665 3 6 GHz VSA and the PXIe 5665 14 GHz VSA Caution The protection provided by this product may be impai...

Страница 3: ...gradation install and use this product in strict accordance with the instructions in the product documentation Furthermore any changes or modifications to the product not expressly approved by Nationa...

Страница 4: ...amage Caution Never touch the exposed pins of connectors Note Do not install a device if it appears damaged in any way 3 Unpack any other items and documentation from the kit Store the device in the a...

Страница 5: ...ble x3 Part Number 763718 01 6 3 6 GHz Version Flexible 5 inch RF SMA to SMA Cable Part Number 190412B 05 14 GHz Version Flexible 7 inch RF SMA to SMA Cable Part Number 190412B 07 7 SMA Driver Bit Par...

Страница 6: ...EF OUT 10 MHz connector on the PXIe 5653 front panel to the REF IN connector on the back of the PXI Express chassis NI RFSA versions 2 5 and later do not require this connection Preparing the Environm...

Страница 7: ...rovides standard IVI based functionality needed for most vector signal analyzer applications Use NI RFSA to create custom measurements or applications that require I Q data Use NI RFSA along with the...

Страница 8: ...the right of the PXIe 5603 or PXIe 5605 RF downconverter module 1 Ensure the AC power source is connected to the chassis before installing the module The AC power cord grounds the chassis and protects...

Страница 9: ...hassis which can improve the signal quality and electromagnetic performance 11 Cover all empty slots using EMC filler panels or fill using slot blockers to maximize cooling air flow depending on your...

Страница 10: ...V p p MAX REF OUT 10 MHz 0 5 V rms REF OUT 100 MHz 0 5 V rms ESD SENSITIVE ACCESS ACTIVE OUT IN LO3 LO2 LO1 ALL PORTS 50 NI PXIe 5603 Downconverter 20 Hz 3 6 GHz RF IN 0 V DC DC COUPLED 25 V DC MAX AC...

Страница 11: ...nel 2 Using the flexible SMA to SMA cable connect the REF OUT 100 MHz connector on the PXIe 5653 front panel to the CLK IN connector on the PXIe 5622 front panel 3 Using the short semi rigid SMA to SM...

Страница 12: ...03 or PXIe 5605 The PXIe 5603 or PXIe 5605 is a precision RF instrument that is sensitive to ESD and transients Ensure you are making proper direct connections to the PXIe 5603 or PXIe 5605 to avoid d...

Страница 13: ...e 5605 Downconverter 20 Hz 14 GHz IF OUT 22 dBm MAX 0 V DC LO1 LO2 LO3 ESD SENSITIVE LO3 LO2 LO1 ALL PORTS 50 15 dBm MAX 25 V DC MAX 15 dBm MAX 0 V DC ACCESS ACTIVE RF IN 0 V DC 20 dBm MAX 10 MHz 10 d...

Страница 14: ...ector is between 2 VDC and 2 VDC With the DC block removed the maximum allowed voltage is 0 VDC Caution To reinstall the DC block on the PXIe 5603 or PXIe 5605 RF IN connector use a torque wrench set...

Страница 15: ...GHz source In multichannel systems LO2 OUT exports the signal received at LO2 IN to other PXIe 5603 or PXIe 5605 modules LO2 OUT is disabled by default LO2 OUT is an SMA connector with an impedance o...

Страница 16: ...eady to be programmed by NI RFSA ACTIVE Indicates the module state OFF The module is in a quiescent state AMBER The module is waiting for the Advance Trigger from the configuration list GREEN The modu...

Страница 17: ...ront panel contains four connectors and two LEDs Figure 7 PXIe 5622 IF Digitizer Module Front Panel ACCESS ACTIVE CLK IN CLK OUT PFI 1 ESD SENSITIVE TTL 6 3 Vp p MAX 2 Vp p NOM 20 dBm MAX 50 50 50 16...

Страница 18: ...5605 RF downconverter for digitization and measurement CLK IN Connects to the 100 MHz REF OUT connector on the PXIe 5653 LO source module This connector is the input terminal for the Reference Clock o...

Страница 19: ...dy to be programmed by NI RFSA ACTIVE Indicates the module state OFF The module is in a quiescent state AMBER The module is waiting for the Advance Trigger from the configuration list GREEN The module...

Страница 20: ...Ds Figure 8 PXIe 5653 Synthesizer LO Source Module Front Panel ESD SENSITIVE ACCESS ACTIVE LO3 800 MHz LO2 4 GHz LO1 3 2 GHz 8 3 GHz OUT ALL PORTS 50 NI PXIe 5653 Synthesizer REF IN 10 MHz 5 V p p MAX...

Страница 21: ...5653 Synthesizer LO Source Front Panel Connectors Connector Use REF IN Routes a frequency reference signal to the RF synthesizer LO source This connector accepts a 10 MHz frequency signal with a maxi...

Страница 22: ...a power rail AMBER The module is being accessed Accessed means that the device setup registers are being written to in order to control the device GREEN The module is ready to be programmed by NI RFSA...

Страница 23: ...alled modules If the module is still not listed power off the system ensure the module is correctly installed and restart 4 Record the identifier MAX assigns to the hardware Use this identifier when p...

Страница 24: ...following situations After first installing and interconnecting your PXIe 5665 system When there is a physical change to any of the system components such as replacement of modules When there is a cha...

Страница 25: ...e directory and import library files located in one of the following directories Windows 10 32 bit 8 1 32 bit 7 32 bit NIDir Shared ExternalCompilerSupport C include Windows 10 64 bit 8 1 64 bit 7 64...

Страница 26: ...les x86 IVI Foundation IVI Microsoft Visual C C Use the header files located in the IVIROOTDIR32 Include directory and import library files located in the IVIROOTDIR32 Lib directory where IVIROOTDIR32...

Страница 27: ...g an Application with Microsoft Visual C and C topic of the NI RF Vector Signal Analyzers Help if you prefer to manually add all required include and library files to the project Programming Examples...

Страница 28: ...mples Troubleshooting If an issue persists after you complete a troubleshooting procedure contact NI technical support or visit ni com support Installation Why Is the ACCESS LED Off When the Chassis I...

Страница 29: ...nfirm that a PXIe 5665 entry appears Note If you are using a PC with a device for PXI remote control system under System Devices also confirm that no error conditions appear for the PCI to PCI Bridge...

Страница 30: ...upport or visit ni com support What Should I Do if the NI RFSA Soft Front Panel Does Not Launch 1 Verify the front panel interconnections for your RF vector signal analyzer 2 Verify the MAX device ass...

Страница 31: ...Learn LabVIEW Basics Getting Started with LabWindows CVI Support ni com support This item is also installed with the driver software EXPLORE LEARN CREATE DISCOVER RF Solutions ni com rf Services ni c...

Страница 32: ...in the DoC for your product by visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration NI corporate headqua...

Страница 33: ...s EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and...

Отзывы: