PXIe-446x modules can be placed in PXI peripheral slots or PXI Express Hybrid
peripheral slots.
6. Touch any metal part of the chassis to discharge static electricity.
7. Ensure that the ejector handle is in the downward (unlatched) position.
8. Place the module edges into the module guides at the top and bottom of the
chassis. Slide the module into the slot until it is fully inserted.
Figure 2.
Module Installation
1
2
3
1. Chassis
2. Hardware Module
3. Ejector Handle in Downward (Unlatched) Position
9. Latch the module in place by pulling up on the ejector handle.
10. Secure the module front panel to the chassis using the front-panel mounting
screws.
Note
Tightening the top and bottom mounting screws increases
mechanical stability and also electrically connects the front
panel to the chassis, which can improve the signal quality and
electromagnetic performance.
11. Cover all empty slots using either filler panels (standard or EMC) or slot
blockers with filler panels, depending on your application.
© National Instruments
7
PXIe-4466/4467/4468 Getting Started Guide