background image

Definitions

Warranted

 specifications describe the performance of a model under stated operating

conditions and are covered by the model warranty.

Characteristics

 describe values that are relevant to the use of the model under stated operating

conditions but are not covered by the model warranty.

Typical

 specifications describe the performance met by a majority of models.

Nominal

 specifications describe an attribute that is based on design, conformance testing,

or supplemental testing.

Specifications are 

Nominal

 unless otherwise noted.

Derating

Remote Sense

Maximum sense lead resistance

100 Ω

Maximum force lead drop

1 V

Voltage accuracy

Add 200 μV to the accuracy specification for
your respective module when using the
PXIe-416

x

 Noise Filter Accessory.

Noise filter cutoff frequency

5 MHz

Load Regulation

Voltage

Add 300 μV/mA to the accuracy specification
for your respective module at the output
connector pins of the connected PXIe-416

x

Noise Filter Accessory when using local sense
configuration.

Physical

Dimensions

8 mm × 72 mm × 16 mm
(2.9 in. × 2.8 in. × 0.6 in.)

Weight

89 g (3.15 oz)

Environmental Guidelines

Notice

 

This model is intended for use in indoor applications only.

6

  | 

ni.com

  | 

PXIe-416x Noise Filter Accessory User Guide

Содержание PXIe-416 Series

Страница 1: ...modify the behavior of the PXIe 4162 PXIe 4163 SMU when the module is used in remote sense mode Caution Observe all instructions and cautions in the user documentation Using the product in a manner n...

Страница 2: ...formation about the PXIe 4162 PXIe 4163 Installing the PXIe 416x Noise Filter Accessory Complete the following steps to install the PXIe 416x Noise Filter Accessory with a PXIe 416x Before you begin i...

Страница 3: ...ry to the PXIe 416x Noise Filter Accessory Refer to your cable or accessory documentation for more information Refer to the following pinouts for your respective module to make the appropriate connect...

Страница 4: ...5 Guard CH5 Sense LO CH6 Output HI CH6 Sense HI CH8 Guard CH8 Sense LO CH9 Output HI CH9 Sense HI CH11 Guard CH11 Sense LO CH0 Guard CH0 Sense LO NC CH2 Output HI CH2 Sense HI CH3 Guard CH3 Sense LO N...

Страница 5: ...ense HI CH19 Output HI CH19 Sense HI CH18 23 Sense LO CH22 Output HI CH22 Sense HI 62 61 60 59 56 55 54 57 50 49 48 51 45 44 43 46 20 21 19 18 17 14 13 12 15 8 7 6 9 10 3 2 1 4 42 41 40 39 38 37 36 35...

Страница 6: ...l unless otherwise noted Derating Remote Sense Maximum sense lead resistance 100 Maximum force lead drop 1 V Voltage accuracy Add 200 V to the accuracy specification for your respective module when us...

Страница 7: ...he Environment web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this doc...

Страница 8: ...compliance for more information and to request relevant import classification codes e g HTS export classification codes e g ECCN and other import export data Product Certifications and Declarations Re...

Страница 9: ...n about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates technical support and ensures that yo...

Страница 10: ...EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and h...

Отзывы: