background image

Chapter 4

Common Configuration Questions

NI PXI-8186 User Manual

4-6

ni.com

The PXI specification allows many combinations of PXI chassis and 
system modules. To assist system integrators, the manufacturers of 
PXI chassis and system modules must document the capabilities of their 
products. The minimum documentation requirements are contained in 

.ini

 files, which consist of ASCII text. System integrators, configuration 

utilities, and device drivers can use these 

.ini

 files. 

The capability documentation for the chassis is contained in a 

chassis.ini

 file provided by the chassis manufacturer. The information 

in this file is combined with information about the system controller to 
create a single system initialization file called 

pxisys.ini

 (PXI System 

Initialization). The NI PXI-8186 uses MAX to generate the 

pxisys.ini

 

file from the 

chassis.ini

 file.

Device drivers and other utility software read the 

pxisys.ini

 file to 

obtain system information. For detailed information about initialization 
files, refer to the PXI specification at 

www.pxisa.org

.

Upgrade Information

How do I upgrade system memory?

You can change the amount of installed RAM on the NI PXI-8186 by 
upgrading the DDR SO-DIMM.

To upgrade the RAM, remove the NI PXI-8186 from the PXI chassis. 
Remove the old SO-DIMM module and install the new SO-DIMM in the 
socket as shown in Figure 4-3. 

National Instruments offers the following types of DDR SO-DIMMs for 
use with the NI PXI-8186 controller. 

512 MB, 64 MB 

×

 64, CL 2.5, 1.25 in. max 

1 GB, 128 MB 

×

 64, CL 2.5, 1.15 in. max

Note

National Instruments has tested and verified that the SO-DIMMs we sell work with 

the NI PXI-8186. We recommend you purchase your SO-DIMM modules from National 
Instruments. Other off-the-shelf SO-DIMM modules are not guaranteed to work properly.

Содержание PXI-8186

Страница 1: ...PXI NI PXI 8186 User Manual NI PXI 8186 User Manual October 2003 Edition Part Number 370747A 01 ...

Страница 2: ... Germany 49 0 89 741 31 30 Greece 30 2 10 42 96 427 India 91 80 51190000 Israel 972 0 3 6393737 Italy 39 02 413091 Japan 81 3 5472 2970 Korea 82 02 3451 3400 Malaysia 603 9131 0918 Mexico 001 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 0 22 3390 150 Portugal 351 210 311 210 Russia 7 095 783 68 51 Singapore 65 6226 5886 Slovenia 386 3 425 420...

Страница 3: ...ion or maintenance instructions owner s modification of the product owner s abuse misuse or negligent acts and power failure or surges fire flood accident actions of third parties or other events outside reasonable control Copyright Under the copyright laws this publication may not be reproduced or transmitted in any form electronic or mechanical including photocopying recording storing in an info...

Страница 4: ...Communications DOC Changes or modifications not expressly approved by NI could void the user s authority to operate the equipment under the FCC Rules Class A Federal Communications Commission This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful ...

Страница 5: ...Installing the NI PXI 8186 2 1 How to Remove the Controller from the PXI Chassis 2 4 BIOS Setup 2 4 Entering BIOS Setup 2 4 Main Setup Menu 2 5 Advanced Setup Menu 2 6 PXI Setup Menu 2 8 Boot Setup Menu 2 9 Exiting BIOS Setup 2 9 System CMOS 2 10 LabVIEW RT Configuration Switches 2 11 Drivers and Software 2 13 Files and Directories Installed on Your Hard Drive 2 13 PXI Features 2 14 PXI Trigger Co...

Страница 6: ...gger 3 10 GPIB IEEE 488 2 3 11 Front Panel Features 3 12 Data Storage 3 12 Chapter 4 Common Configuration Questions General Questions 4 1 Boot Options 4 1 Cables and Connections 4 2 Software Driver Installation 4 3 Chassis Configuration 4 4 Upgrade Information 4 6 PXI Configuration 4 8 Chapter 5 Troubleshooting Appendix A Specifications Appendix B Technical Support and Professional Services Glossa...

Страница 7: ...ect the Page Setup item and select Options from the last dialog box This icon denotes a note which alerts you to important information This icon denotes a caution which advises you of precautions to take to avoid injury data loss or a system crash bold Bold text denotes items that you must select or click in the software such as menu items and dialog box options Bold text also denotes parameter na...

Страница 8: ...n you may find helpful as you read this manual PICMG 2 0 R3 0 CompactPCI Specification PCI Industrial Computers Manufacturers Group IEEE Standard P1284 1 1997 C MM Standard for Information Technology for Transport Independent Printer System Interface PCI Local Bus Specification Revision 2 2 PCI Special Interest Group PXI Hardware Specification Revision 2 1 PXI Systems Alliance PXI Software Specifi...

Страница 9: ...ctPCI specification which defines a rugged form factor for PCI that offers superior mechanical integrity and easy installation and removal of hardware components PXI products offer higher and more carefully defined levels of environmental performance required by the vibration shock temperature and humidity extremes of industrial environments PXI adds mandatory environmental testing and active cool...

Страница 10: ... such as the PXI 1042 results in a fully PC compatible computer in a compact rugged package The NI PXI 8186 has a 2 2 GHz processor all the standard I O a second serial port a PCI based GPIB controller and a 20 GB or larger hard drive Functional Overview This section contains functional descriptions of each major logic block on the NI PXI 8186 embedded computers NI PXI 8186 Functional Description ...

Страница 11: ...r Flash ROM ATA 100 IDE Interface SO DIMM DDR SDRAM PC 2100 Chip Set Graphics Memory Controller Hub VGA Connector Socket 478 CPU Keyboard Mouse Super I O COM 1 COM 2 LPT 1 Chip Set I O Controller Hub PXI Triggers 2 Hi Speed USB 2 0 Connectors 10 100BaseT Ethernet SMB to PXI Trigger Watchdog SMB Hub Interface LPC Bus PS 2 PCI Bus GPIB ...

Страница 12: ...SB 2 0 interface The PXI Connector connects the NI PXI 8186 to the PXI CompactPCI backplane The Keyboard Mouse block contains the PS 2 keyboard and mouse interface The Super I O block represents the other peripherals supplied by the NI PXI 8186 The NI PXI 8186 has two serial ports an ECP EPP parallel port and a PS 2 keyboard and mouse port The IDE block is dedicated PCI IDE circuitry providing fas...

Страница 13: ...include all the tools needed for instrument control data acquisition analysis and presentation LabVIEW is an easy to use graphical programming environment you can use to acquire data from thousands of different instruments including IEEE 488 2 devices VXI devices serial devices PLCs and plug in data acquisition boards After you have acquired raw data you can convert it into meaningful results usin...

Страница 14: ... NI PXI 8186 The power cord grounds the chassis and protects it from electrical damage while you install the module Make sure the power switch is turned off Caution To protect both yourself and the chassis from electrical hazards leave the chassis powered off until you finish installing the NI PXI 8186 module 2 Remove any filler panels blocking access to the system controller slot Slot 1 in the ch...

Страница 15: ...properly unless the handle is in its downward position so that it does not interfere with the injector rail on the chassis 6 Hold the handle as you slowly slide the module into the chassis until the handle catches on the injector ejector rail 7 Raise the injector ejector handle until the module firmly seats into the backplane receptacle connectors The front panel of the NI PXI 8186 should be even ...

Страница 16: ...ut an adaptor 11 Connect the VGA monitor video cable to the VGA connector 12 Connect devices to ports as required by your system configuration 13 Power on the chassis 14 Verify that the controller boots If the controller does not boot refer to the What if the NI PXI 8186 does not boot section of Chapter 5 Troubleshooting Figure 2 2 shows an NI PXI 8186 installed in the system controller slot of a ...

Страница 17: ... that work well for most configurations Caution Changing BIOS settings may lead to incorrect controller behavior and possibly an unbootable controller If this happens follow the instructions for restoring default settings in the System CMOS section In general do not change a setting unless you are absolutely certain what it does Entering BIOS Setup To start the BIOS setup utility complete the foll...

Страница 18: ...a way to change this setting Use and in conjunction with Enter and Tab to change these values DMI Event Logging This setting brings up the DMI Event Logging submenu Refer to the DMI Event Logging Submenu section Require Keyboard to Boot When Yes a missing or malfunctioning keyboard causes the BIOS to halt with an error When No the BIOS allows booting without a keyboard If you are using a USB keybo...

Страница 19: ...ther events are logged Disabling logging has no impact on system performance The default is Enabled Advanced Setup Menu This menu contains BIOS settings that normally do not require modification If you have specific problems such as unbootable disks or resource conflicts you may need to examine these settings Caution Changing settings in this menu may result in an unstable or unbootable controller...

Страница 20: ...a network PXE server on the subnet The default is Disabled Write Protect Boot Sector When set to Yes this setting prevents modification of a hard disk boot sector via INT 13h services which may help prevent certain computer viruses from infecting the controller This setting does not prevent boot sector modification by 32 bit operating system drivers that access the hard disk directly The default i...

Страница 21: ... Note These settings override the behavior of the switches on S1 Refer to the LabVIEW RT Configuration Switches section for more information To use the settings from the switches select Use Hardware Switch for each option Boot Configuration This setting selects whether the controller should boot LabVIEW RT LabVIEW RT Safe Mode or an installed OS such as Windows XP The default is Use Hardware Switc...

Страница 22: ...includes all IDE ATA and USB hard disks detected on the system Press Enter on this entry to expand it to select the boot priority of individual IDE ATA hard drives CD ROM Drive The boot list includes all classes of CD ROM drive including USB drives and IDE ATA drives Note If an SCSI host adapter exists in the system this menu has an additional entry for SCSI devices Note If PXE Network Boot is ena...

Страница 23: ...this session of the BIOS setup program are discarded Unlike Exit Discarding Changes however the BIOS setup continues to be active Save Changes Changes made to BIOS settings during this session are committed to battery backed System CMOS The setup program remains active allowing further changes System CMOS The NI PXI 8186 contains a backed up memory used to store BIOS configuration information Comp...

Страница 24: ...EW RT these switches should remain in the OFF position The controller reads these switches only after a system reset You must reboot the controller for any changes to take place The NI PXI 8186 controller includes the following LabVIEW RT configuration switches Switch 1 Boot LabVIEW RT Set this switch to ON to boot LabVIEW RT Switch 2 Boot Safe Mode Set this switch to ON to boot LabVIEW RT into sa...

Страница 25: ...ent VIs from automatically running at startup if the controller becomes inaccessible because of a startup VI Switch 4 Reset IP Address Set this switch to ON to reset the IP address to 0 0 0 0 and other TCP IP settings to their defaults Use this switch if moving the controller to a different subnet or if the current TCP IP settings are invalid Figure 2 4 shows the location of the LabVIEW RT configu...

Страница 26: ...manual change your directory to c images pxi 8180 manuals and list the contents of that directory You will see several files one corresponding to each peripheral The os directory contains a subdirectory corresponding to the operating system installed on your computer The rest of the directories correspond to each peripheral in your system Within each of these directories are the drivers for the pe...

Страница 27: ...Contact National Instruments or refer to KnowledgeBase 2RCBPFWD at ni com support for more information Upgrading RAM You can change the amount of installed RAM on the NI PXI 8186 by upgrading the SO DIMM To upgrade the RAM remove the NI PXI 8186 from the PXI chassis Remove the old SO DIMM module and install the new SO DIMM in the socket as shown in Figure 2 5 National Instruments offers the follow...

Страница 28: ... of the hard disk provided to you at the time of shipment Should you need to restore your software to its original condition you can access that image by pressing a hot key during the initial boot process For more information regarding these tools refer to the documentation on your hard drive in the c Images Firstware directory Note Your system hot key is F4 To access the Phoenix Firstware Recover...

Страница 29: ...ng the install process because it does not have drivers for the CD ROM device With DOS drivers you can install Windows 9x operating systems However only a few USB CD ROM drives have DOS drivers As an alternative to a USB CD ROM drive you can use an external SCSI CD ROM with a PXI SCSI adapter Installing from a Network Complete the following steps to install an OS from a network 1 Create a network ...

Страница 30: ...SUB Intel Extreme Graphics controller Serial COM1 9 pin DSUB 16550 RS 232 serial port Serial COM2 9 pin DSUB 16550 RS 232 serial port Ethernet LAN RJ45 10 100 Ethernet connection Parallel Parallel Port 36 pin champ IEEE 1284 USB USB 4 pin Series A stacked receptacle USB 2 0 capable Keyboard mouse PS 2 5 pin Din PS 2 style keyboard and mouse mouse requires PS 2 Y splitter PXI trigger Trigger SMB Ro...

Страница 31: ... of the NI PXI 8186 Dimensions are in inches millimeters Figure 3 1 NI PXI 8186 Front Panel Layout and Dimensions 3 69 93 7 2 10 53 3 0 89 22 6 0 00 0 3 93 99 8 3 46 87 9 2 79 70 9 1 83 46 5 0 82 20 8 1 49 37 8 2 00 50 8 2 29 58 2 2 33 59 2 0 00 0 0 76 19 3 0 83 21 1 1 26 32 0 2 22 56 4 2 32 58 9 NI PXI 8186 Embedded Controller ...

Страница 32: ...the VGA connector signals AMP manufactures a mating connector with part numbers 748364 1 housing and 748333 2 pin contact Figure 3 2 VGA Connector Location and Pinout Table 3 2 VGA Connector Signals Pin Signal Name Signal Description 1 R Red 2 G Green 3 B Blue 4 NC Not Connected 5 GND Ground 6 GND Ground 7 GND Ground 8 GND Ground 9 5V 5 V 10 GND Ground VGA 11 6 1 15 10 5 NI PXI 8186 Embedded Contr...

Страница 33: ... the COM1 and COM2 connector signal AMP manufactures a serial port mating connector part number 745491 5 Figure 3 3 COM1 and COM2 Connector Location and Pinout 11 NC Not Connected 12 SD Serial Data 13 HSync Horizontal Sync 14 VSync Vertical Sync 15 SC Serial Clock Table 3 2 VGA Connector Signals Continued Pin Signal Name Signal Description 1 5 9 6 COM2 1 5 9 6 COM1 NI PXI 8186 Embedded Controller ...

Страница 34: ...onnector signals AMP manufactures a mating connector part number 554739 1 Figure 3 4 Ethernet Connector Location and Pinout Table 3 3 COM1 and COM2 Connector Signals Pin Signal Name Signal Description 1 DCD Data Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Ground 6 DSR Data Set Ready 7 RTS Ready to Send 8 CTS Clear to Send 9 RI Ring Indicator Ethernet 1 8 N...

Страница 35: ...e IEEE 1284 connector signals Parallel port adapter cables are available from National Instruments part number 777169 01 Figure 3 5 Parallel Port Connector Location and Pinout Table 3 4 Ethernet Connector Signals Pin Signal Description 1 Differential Transmit 2 Differential Transmit 3 Differential Receive 4 NC 5 NC 6 Differential Receive 7 NC 8 NC Parallel Port 1 18 19 36 NI PXI 8186 Embedded Cont...

Страница 36: ...scription 1 BUSY Device Busy 2 SLCT Select 3 ACK Acknowledge 4 FAULT ERROR Fault 5 PAPEREND Paper End 6 PD0 Data Bit 0 7 PD1 Data Bit 1 8 PD 2 Data Bit 2 9 PD3 Data Bit 3 10 PD4 Data Bit 4 11 PD5 Data Bit 5 12 PD6 Data Bit 6 13 PD7 Data Bit 7 14 INIT Initialize Printer 15 STROBE Strobe 16 SLCTIN Select Input 17 AUTOFD Auto Line Feed 18 5V 5 V 19 35 GND Ground 36 NC Not Connected ...

Страница 37: ...nnector on the NI PXI 8186 Table 3 6 lists and describes the USB connector signals AMP manufactures a USB mating connector part number 787633 Figure 3 6 USB Connector Location and Pinout Table 3 6 USB Connector Signals Pin Signal Name Signal Description 1 VCC Cable Power 5 V 2 Data USB Data 3 Data USB Data 4 GND Ground USB 4 1 NI PXI 8186 Embedded Controller ...

Страница 38: ...luded with your controller refer to Figure 4 1 Y Splitter Cable Replacement Y splitter adapter cables are available from National Instruments part number 778713 01 Figure 3 7 PS 2 Connector Location and Pinout Table 3 7 PS 2 Connector Signals Pin Signal Name Signal Description Y Splitter Keyboard Y Splitter Mouse 1 DATA Data Keyboard Data Keyboard Data Mouse 2 NC Data Mouse NC NC 3 GND Ground GND ...

Страница 39: ...triggers to or from the backplane trigger bus Figure 3 8 shows the TRG connector location on the NI PXI 8186 Table 3 8 lists and describes the trigger connector signals Figure 3 8 TRG Connector Location and Pinout Table 3 8 TRG Connector Signals Pin Signal Name Signal Description 1 TRIG Trigger 2 Shield GND Ground 1 2 NI PXI 8186 Embedded Controller ...

Страница 40: ... ITT Canon manufactures a GPIB mating connector part number MDSM 25SC Z11 V51 Figure 3 9 GPIB Connector Location and Pinout Table 3 9 GPIB Connector Signals Pin Signal Name Signal Description 1 DIO1 Data Bit 1 2 DIO2 Data Bit 2 3 DIO3 Data Bit 3 4 DIO4 Data Bit 4 5 EOI End or Identify 6 DAV Data Valid 7 NRFD Not Ready for Data 8 NDAC Not Data Accepted 9 IFC Interface Clear 10 SRQ Service Request G...

Страница 41: ...ted The DRIVE LED indicates when an access to the internal hard disk is occurring Data Storage The NI PXI 8186 has the following data storage features Internal IDE hard drive 2 5 in notebook hard drive Supports up to ATA 5 UDMA 100 USB storage support USB CD ROM mass storage device or floppy drive 11 ATN Attention 12 SHIELD Chassis ground 13 DIO5 Data Bit 5 14 DIO6 Data Bit 6 15 DIO7 Data Bit 7 16...

Страница 42: ...e NI PXI 8186 How do I check the configuration of the memory hard drive time date and so on You can view these parameters in the BIOS setup To enter the BIOS setup reboot the NI PXI 8186 and press Delete during the memory tests Refer to the Entering BIOS Setup section of Chapter 2 Installation and Configuration for more information Can I use the internal IDE drive and an external SCSI hard drive a...

Страница 43: ...ice type and set the order for the devices listed within the device type To boot from a different device without permanently changing the boot order press Esc during POST After the BIOS completes the POST and just before the controller boots the OS the Boot menu is displayed You can select the device type you want to boot from Note Two devices cannot share the same IDE channel and doing so may dam...

Страница 44: ...allel port adapter cables part number 777169 01 are available through the online catalog at ni com products Software Driver Installation How do I install or reinstall the video driver Refer to the Drivers txt file on the hard drive or recovery CD ROM How do I install or reinstall the Ethernet driver Refer to the Drivers txt file on the hard drive or recovery CD ROM How do I install or reinstall th...

Страница 45: ...ndor to make sure Windows XP supports the drive Mapped network drive You can use the Ethernet to connect to another computer If you share the CD ROM drive on the other computer you can map the shared CD ROM drive to a drive letter on the NI PXI 8186 Chassis Configuration How do I set up the NI PXI 8186 to work with my chassis Configuration of the PXI system is handled through Measurement Automatio...

Страница 46: ...Right click this entry to display the pop up menu then select the appropriate controller model from the Identify As submenu 4 Click the PXI System controller The chassis or multiple chassis in a multichassis configuration is listed below it Identify each chassis by right clicking its entry then selecting the appropriate chassis model through the Identify As submenu Further expanding the PXI System...

Страница 47: ...es MAX to generate the pxisys ini file from the chassis ini file Device drivers and other utility software read the pxisys ini file to obtain system information For detailed information about initialization files refer to the PXI specification at www pxisa org Upgrade Information How do I upgrade system memory You can change the amount of installed RAM on the NI PXI 8186 by upgrading the DDR SO DI...

Страница 48: ...n an NI PXI 8186 Controller How do I flash a new BIOS You need to download the new BIOS from ni com support pxisupp htm To download the new BIOS follow the instructions on the Web site Where do I get the latest software drivers You can download the latest drivers from ni com support pxisupp htm 1 DDR SO DIMM Module 2 DDR SO DIMM Socket 1 2 ...

Страница 49: ...oot Options section for more information A USB floppy drive is available from National Instruments part number 778492 02 PXI Configuration How do I use the SMB trigger on the front panel For details refer to the PXI Features section of Chapter 2 Installation and Configuration Why doesn t the NI PXI 8186 work with the PXI 8220 A serialized IRQ conflict with the PXI 8220 and the NI PXI 8186 prevents...

Страница 50: ... last screen output that you saw for reference when consulting National Instruments technical support What has changed about the system Did you recently move the system Was there electrical storm activity Did you recently add a new module memory chip or piece of software Things to Try Make sure the chassis is plugged in to a working power source Check any fuses or circuit breakers in the chassis o...

Страница 51: ...s a particular module is not in my chassis The most common cause of this is a damaged module Try the module in a different chassis or with a different controller Also remove any external cables or terminal blocks connected to the system If the module does not work in these cases it is likely damaged Contact the module manufacturer for further troubleshooting Refer to the KnowledgeBase or product m...

Страница 52: ...orporation 5 3 NI PXI 8186 User Manual Caution Do not leave the jumper on pins 2 3 Doing so decreases battery life Also the controller will not boot Figure 5 1 Clearing the CMOS Contents 1 Normal Operation Default 2 Clear CMOS Contents 3 Pin 1 1 2 3 ...

Страница 53: ... 8186 embedded computer Electrical Physical Board dimensions PXI 3U size module 8 1 by 13 by 21 6 cm 3 2 by 5 1 by 8 5 in Slot requirements One system slot plus three controller expansion slots Compatibility Fully compatible with PXI specification MTBF TBD Weight 1 0 Kg 2 2 lb typical Voltage V Current A Typical Maximum 3 3 4 A 5 A 5 6 5 A 8 A 12 0 15 A 0 2 A 12 0 A 0 A ...

Страница 54: ...nd free from contaminants before returning it to service Storage Environment NI PXI 8186 Ambient temperature range 20 to 65 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 NI PXI 8186 Extended Temp Option Ambient temperature range 40 to 85 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Chassis NI PXI 8186 NI PXI 8186 Extended Temperature Option PXI 1000B 5 40 C 0 55 C PXI ...

Страница 55: ... filler panels must be installed Refer to the Declaration of Conformity DoC for this product for any additional regulatory compliance information To obtain the DoC for this product click Declaration of Conformity at ni com hardref nsf This Web site lists the DoCs by product family Select the appropriate product family followed by your product and a link to the DoC appears in Adobe Acrobat format C...

Страница 56: ... CE Compliance This product meets the essential requirements of applicable European Directives as amended for CE Marking as follows Low Voltage Directive safety 73 23 EEC Electromagnetic Compatibility Directive EMC 89 336 EEC Note Refer to the Declaration of Conformity DoC for this product for any additional regulatory compliance information To obtain the DoC for this product visit ni com hardref ...

Страница 57: ...surement glossary and so on Assisted Support Options Contact NI engineers and other measurement and automation professionals by visiting ni com support Our online system helps you define your question and connects you to the experts by phone discussion forum or email Training Visit ni com training for self paced tutorials videos and interactive CDs You also can register for instructor led hands on...

Страница 58: ...om calibration If you searched ni com and could not find the answers you need contact your local office or NI corporate headquarters Phone numbers for our worldwide offices are listed at the front of this manual You also can visit the Worldwide Offices section of ni com niglobal to access the branch office Web sites which provide up to date contact information support phone numbers email addresses...

Страница 59: ...micro 10 6 m milli 10 3 k kilo 103 M mega 106 G giga 109 T tera 1012 Symbols Degrees Ω Ohms Percent A A Amperes AC Alternating Current ASIC Application specific integrated circuit B B Bytes backplane An assembly typically a printed circuit board with connectors and signal paths that bus the connector pins ...

Страница 60: ...d or embedded applications that require a more robust mechanical form factor than desktop PCI CompactPCI provides a standard form factor for those applications requiring the high performance of PCI as well as the small size and ruggedness of a rack mount system D DC Direct Current DDR Double Data Rate DIMM Dual In line Memory Module DMA Direct Memory Access a method by which data is transferred be...

Страница 61: ...Enhanced Parallel Port expansion ROM An onboard EEPROM that may contain device specific initialization and system boot functionality F FCC Federal Communications Commission G g 1 Grams 2 A measure of acceleration equal to 9 8 m s2 GPIB General Purpose Interface Bus IEEE 488 grms A measure of random vibration the root mean square of acceleration levels in a random vibration test profile H Hz Hertz ...

Страница 62: ...ication between machines and users IRQ Interrupt signal ISA Industry Standard Architecture the original PC bus architecture specifically the 16 bit AT bus K KB Kilobytes of memory L LAN Local Area Network communications network that serves users within a confined geographical area It is made up of servers workstations a network operating system and a communications link LED Light emitting diode M ...

Страница 63: ... Personal Computer Memory Card International Association peripheral Any hardware device connected to a computer such as a monitor keyboard printer plotter disk or tape drive graphics tablet scanner mouse and so on POSC Power On Self Configuration PXI PCI eXtensions for Instrumentation an open implementation of CompactPCI that adds electrical features that meet the high performance requirements of ...

Страница 64: ...s SO DIMM Small Outline Dual In line Memory Module SRAM Static RAM a memory chip that requires power to hold its content It does not require refresh circuitry as a dynamic RAM chip but it does take up more space and uses more power ST Start Trigger Star Trigger Slot This slot is located at Slot 2 in a PXI mainframe and has a dedicated trigger line between each peripheral slot This slot would be us...

Страница 65: ... options 4 1 cables and connections 4 2 chassis configuration 4 4 driver installation 4 3 general questions 4 1 PXI configuration 4 8 upgrade information 4 6 CompactPCI specification 1 1 configuration common questions boot options 4 1 cables and connections 4 2 chassis configuration 4 4 driver installation 4 3 general questions 4 1 PXI configuration 4 8 upgrade information 4 6 connectors COM1 and ...

Страница 66: ...sing external floppy drive 4 8 front panel connectors 3 1 dimensions 3 2 features 3 12 functional overview of NI PXI 8186 1 2 G GPIB IEEE 488 2 3 11 connector location and pinout figure 3 11 connector signals table 3 11 driver installation 4 3 H hard drive 3 12 files and directories installed on 2 13 recovery 2 15 help technical support B 1 I IDE controller using SCSI hard drive in addition 4 1 ID...

Страница 67: ...IOS setup 2 4 block diagram 1 3 connectors 3 1 COM1 and COM2 connectors and signals 3 4 GPIB IEEE 488 2 connector and signals 3 11 parallel port connector and signals 3 6 PS 2 connector and signals 3 9 trigger connector and signals 3 10 Universal Serial Bus USB connector and signals 3 8 VGA connector and signals table 3 3 data storage 3 12 front panel features 3 12 LEDs 4 1 system reset pushbutton...

Страница 68: ... 2 14 PXI 8220 using NI PXI 8186 with 4 8 pxisys ini file 4 4 R RAM DDR SO DIMMs from National Instruments note 2 14 4 6 upgrading 2 14 4 6 related documentation viii S safety specifications A 3 serial ports 3 1 See also COM1 and COM2 connectors shock and vibration specifications A 3 socket 478 1 CPU 1 4 SO DIMM logic block 1 4 software See also drivers installed on your hard drive 2 13 installing...

Страница 69: ... video display 5 2 troubleshooting NI resources B 1 U Universal Serial Bus USB 3 1 3 8 connector function 1 4 connector location and pinout figure 3 8 connector signals table 3 8 overview table 3 1 V VGA connector signals table 3 3 location and pinout figure 3 3 overview table 3 1 video 3 1 See also VGA driver installation 4 3 W Web resources B 1 Y Y splitter cable figure 4 2 obtaining replacement...

Отзывы: