background image

160-Pin Cable for the NI PXI-2530B Installation Instructions

2

ni.com

The following figure shows the 160-pin cable for the NI PXI-2530B.

Figure 1.  

160-Pin Cable for the NI PXI-2530B

What You Need to Get Started

To use the cable, you need the following items:

160-pin cable for the NI PXI-2530B

(Optional) Four NI TBX-50 screw terminal blocks

NI PXI-2530B switch module and documentation

#1 Phillips screwdriver

1

160-Pin Cable for the NI PXI-2530B Backshell

2

Cable Leg Labels

3

50-Pin Female D-SUB Connector Backshells

4

Thumbscrews

 NA

TIONAL 

INSTRUMENTS

 NA

TIONAL 

INSTRUMENTS

 NA

TIONAL 

INSTRUMENTS

 NA

TIONAL 

INSTRUMENTS

 NA

TIONAL 

INSTRUMENTS

1

4

2

3

60VDC/30VRMS CA

T I ONL

Y

6

0

V

D

C

/3

0

V

R

M

S

 C

A

T

 I

 O

N

LY

NATIONAL IN

S

TRUMENT

S

P1

P2

P

3

P4

Содержание PXI-2530B

Страница 1: ... 14 About the Cable Use this shielded cable to connect the NI PXI 2530B switch module to your application As illustrated in Figure 1 one end of the cable connects to the NI PXI 2530B and the other end of the cable terminates with four 50 pin female D SUB connectors This cable is designed for use with the NI PXI 2530B and will not mate with the NI PXI 2530 Caution Refer to the Read Me First Safety ...

Страница 2: ...pin cable for the NI PXI 2530B Optional Four NI TBX 50 screw terminal blocks NI PXI 2530B switch module and documentation 1 Phillips screwdriver 1 160 Pin Cable for the NI PXI 2530B Backshell 2 Cable Leg Labels 3 50 Pin Female D SUB Connector Backshells 4 Thumbscrews NATIONAL INSTRUMENTS NATIONAL INSTRUMENTS NATIONAL INSTRUMENTS NATIONAL INSTRUMENTS NATIONAL INSTRUMENTS 1 4 2 3 60VDC 30VRMS CAT I ...

Страница 3: ... module as shown in Figure 2 Figure 2 Connecting the Cable to the NI PXI 2530B 2 Tighten the chassis screws on the cable 3 Connect the D SUB connectors on the cable to your application Refer to Tables 1 through 4 in the Cable Configuration section to determine how to connect signals to your application For screw terminal access you can connect directly to NI TBX 50 terminal blocks 1 Backshell 2 Ch...

Страница 4: ...res 3 and 4 show the pinouts for both connectors Use the pinouts and the pin assignments listed in Tables 1 through 4 to determine how to connect signals to your application Refer to the NI Switches Help for a complete listing of channel names and pinouts Figure 3 NI PXI 2530B Mating Connector Figure 4 50 Pin Female D SUB Connector Pin 41 Pin 40 Pin 1 Pin 80 Pin 120 Pin 121 Pin 160 Pin 81 Pin 1 Pi...

Страница 5: ...2530B Channel Interface Connector Pin 1 CH64 120 2 CH65 121 3 CH66 119 4 CH67 122 5 CH68 118 6 CH69 123 7 CH70 117 8 CH71 124 9 CH72 116 10 CH73 125 11 CH74 115 12 CH75 126 13 CH76 114 14 CH77 127 15 CH78 113 16 CH79 128 17 CH80 111 18 CH81 130 19 CH82 112 20 CH83 129 21 CH84 109 22 CH85 132 23 CH86 108 24 CH87 133 25 CH88 107 26 CH89 134 27 CH90 106 28 CH91 135 29 CH92 105 30 CH93 136 ...

Страница 6: ... No Connect 38 No Connect 39 No Connect 40 No Connect 41 No Connect 42 No Connect 43 No Connect 44 No Connect 45 No Connect 46 No Connect 47 No Connect 48 No Connect 49 No Connect 50 No Connect P1 Shell GND Shell Table 1 Pin Assignments for D SUB Backshell P1 Continued 50 Pin D SUB Backshell P1 D SUB Pin NI PXI 2530B Channel Interface Connector Pin ...

Страница 7: ...P2 D SUB Pin NI PXI 2530B Channel Interface Connector Pin 1 CH0 41 2 CH1 40 3 CH2 42 4 CH3 39 5 CH4 43 6 CH5 38 7 CH6 44 8 CH7 37 9 CH8 45 10 CH9 36 11 CH10 46 12 CH11 35 13 CH12 47 14 CH13 34 15 CH14 48 16 CH15 33 17 CH16 50 18 CH17 31 19 CH18 49 20 CH19 32 21 CH20 52 22 CH21 29 23 CH22 53 24 CH23 28 25 CH24 54 26 CH25 27 27 CH26 55 28 CH27 26 29 CH28 56 30 CH29 25 ...

Страница 8: ... Connect 38 No Connect 39 No Connect 40 No Connect 41 No Connect 42 No Connect 43 No Connect 44 No Connect 45 No Connect 46 No Connect 47 No Connect 48 No Connect 49 No Connect 50 No Connect P2 Shell GND Shell Table 2 Pin Assignments for D SUB Backshell P2 Continued 50 Pin D SUB Backshell P2 D SUB Pin NI PXI 2530B Channel Interface Connector Pin ...

Страница 9: ... D SUB Pin NI PXI 2530B Channel Interface Connector Pin 1 CH32 67 2 CH33 15 3 CH34 12 4 CH35 11 5 CH36 70 6 CH37 61 7 CH38 20 8 CH39 62 9 CH40 19 10 CH41 63 11 CH42 18 12 CH43 64 13 CH44 17 14 CH45 65 15 CH46 16 16 CH47 66 17 CH48 14 18 CH49 68 19 CH50 13 20 CH51 69 21 CH52 1 22 CH53 4 23 CH54 3 24 CH55 71 25 CH56 10 26 CH57 72 27 CH58 9 28 CH59 73 29 CH60 8 30 CH61 74 ...

Страница 10: ...Connect 38 No Connect 39 No Connect 40 No Connect 41 No Connect 42 No Connect 43 No Connect 44 No Connect 45 No Connect 46 No Connect 47 No Connect 48 No Connect 49 No Connect 50 No Connect P3 Shell GND Shell Table 3 Pin Assignments for D SUB Backshell P3 Continued 50 Pin D SUB Backshell P3 D SUB Pin NI PXI 2530B Channel Interface Connector Pin ...

Страница 11: ... Channel Interface Connector Pin 1 CH96 94 2 CH97 149 3 CH98 91 4 CH99 150 5 CH100 146 6 CH101 100 7 CH102 141 8 CH103 99 9 CH104 142 10 CH105 98 11 CH106 143 12 CH107 97 13 CH108 144 14 CH109 96 15 CH110 145 16 CH111 95 17 CH112 147 18 CH113 93 19 CH114 148 20 CH115 92 21 CH116 85 22 CH117 81 23 CH118 157 24 CH119 90 25 CH120 151 26 CH121 89 27 CH122 152 28 CH123 88 29 CH124 153 30 CH125 87 ...

Страница 12: ... DGND 158 38 TRIGIN 159 39 TRIGOUT 82 40 No Connect 41 No Connect 42 No Connect 43 No Connect 44 No Connect 45 No Connect 46 No Connect 47 No Connect 48 No Connect 49 No Connect 50 No Connect P4 Shell GND Shell Table 4 Pin Assignments for D SUB Backshell P4 Continued 50 Pin D SUB Backshell P4 D SUB Pin NI PXI 2530B Channel Interface Connector Pin ...

Страница 13: ...tromagnetic Compatibility document at ni com manuals for more information about Measurement Categories Weight 1206 6 g 42 6 oz Environment Operating temperature 0 C to 55 C Storage temperature 20 C to 70 C Relative humidity 5 to 85 noncondensing Pollution Degree 2 Maximum altitude 2 000 m Indoor use only Safety This product meets the requirements of the following standards of safety for electrical...

Страница 14: ...ielded cables or accessories are not properly installed and shielded the EMC specifications for the product are no longer guaranteed Caution You must install mating connectors according to local safety codes and standards and according to the specifications provided by the connector manufacturer You are responsible for verifying safety compliance of third party connectors and their usage according...